A pilot study of a novel screw design for early callus formation in minimally invasive hallux valgus correction

Background Minimally invasive hallux valgus correction surgery is gaining popularity; however, the influence of fixation configuration on early osteotomy healing remains insufficiently understood. We developed a novel screw design with a segmented geometry intended to modify the mechanical environment of the osteotomy while maintaining bone purchase in the first metatarsal head. This study aims to evaluate the early radiographic healing characteristics and radiographic correction achieved using this novel screw construct. Methods Twenty-one patients underwent bilateral minimally invasive hallux valgus surgery between 2024 and 2025. A bilateral intra-patient controlled design was used, with one foot fixed using two conventional screws (Group A) and the contralateral foot fixed using one conventional screw and one novel screw (Group B). Fifteen patients who completed a minimum of one year of follow-up were retrospectively reviewed. Hallux valgus angle (HVA), intermetatarsal angle (IMA), early callus formation, final radiographic union, complications, and patient satisfaction were evaluated. Results The mean HVA improved from 28.8° to 4.6° in Group A and from 29.3° to 4.5° in Group B (both p < 0.001). The mean IMA improved from 12.1° to 4.9° in Group A and from 12.2° to 5.0° in Group B (both p < 0.001). No significant differences were observed between the groups in final HVA or IMA. At the early postoperative radiographic assessment, approximately 4 months, callus formation was significantly greater in Group B than in Group A (p = 0.020). Complete radiographic union was observed in 29 of 30 feet at final follow-up; one foot in Group A demonstrated partial union. One symptomatic hardware complication requiring removal occurred in Group A. Conclusions The novel screw construct was associated with greater early radiographic callus formation while maintaining correction of hallux valgus deformity in this pilot study. These findings support further biomechanical and prospective clinical investigation of fixation configuration in minimally invasive hallux valgus osteotomy. Level of evidence III, retrospective comparative study.

Authors

Institutions

Publication Details

Journal
BMC Musculoskeletal Disorders
Published
2026-11-26
DOI
https://doi.org/10.1186/s12891-026-10770-8
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A pilot study of a novel screw design for early callus formation in minimally invasive hallux valgus correction

Ji Young Jeon, Dong‐Oh Lee, Sang Gyo Seo, Taebyeong Kang et al.
BMC Musculoskeletal Disorders
Foot and Ankle Surgery
article

A pilot study of a novel screw design for early callus formation in minimally invasive hallux valgus correction

Ji Young Jeon, Dong‐Oh Lee, Sang Gyo Seo, Taebyeong Kang, Jeong Hwan Lee
article en

Abstract

Background Minimally invasive hallux valgus correction surgery is gaining popularity; however, the influence of fixation configuration on early osteotomy healing remains insufficiently understood. We developed a novel screw design with a segmented geometry intended to modify the mechanical environment of the osteotomy while maintaining bone purchase in the first metatarsal head. This study aims to evaluate the early radiographic healing characteristics and radiographic correction achieved using this novel screw construct. Methods Twenty-one patients underwent bilateral minimally invasive hallux valgus surgery between 2024 and 2025. A bilateral intra-patient controlled design was used, with one foot fixed using two conventional screws (Group A) and the contralateral foot fixed using one conventional screw and one novel screw (Group B). Fifteen patients who completed a minimum of one year of follow-up were retrospectively reviewed. Hallux valgus angle (HVA), intermetatarsal angle (IMA), early callus formation, final radiographic union, complications, and patient satisfaction were evaluated. Results The mean HVA improved from 28.8° to 4.6° in Group A and from 29.3° to 4.5° in Group B (both p < 0.001). The mean IMA improved from 12.1° to 4.9° in Group A and from 12.2° to 5.0° in Group B (both p < 0.001). No significant differences were observed between the groups in final HVA or IMA. At the early postoperative radiographic assessment, approximately 4 months, callus formation was significantly greater in Group B than in Group A (p = 0.020). Complete radiographic union was observed in 29 of 30 feet at final follow-up; one foot in Group A demonstrated partial union. One symptomatic hardware complication requiring removal occurred in Group A. Conclusions The novel screw construct was associated with greater early radiographic callus formation while maintaining correction of hallux valgus deformity in this pilot study. These findings support further biomechanical and prospective clinical investigation of fixation configuration in minimally invasive hallux valgus osteotomy. Level of evidence III, retrospective comparative study.

BMC Musculoskeletal Disorders
Asan Medical Center (KR), Seoul National University Hospital (KR)
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon