Degradation-Aware Lifecycle Efficiency Modeling and Extremum-Seeking Control of Proton Exchange Membrane Water Electrolyzers

This study develops and numerically assesses a degradation-aware, multirate operating framework for proton exchange membrane water electrolyzers (PEMWEs) under variable renewable-type loads. The contribution is not a new electrochemical constitutive law; rather, it is the explicit integration of (i) a health-state-dependent system-efficiency map, (ii) irreversible-heat feedforward compensation for fast electrothermal disturbances, and (iii) load-compensated extremum-seeking control (ESC) for slower tracking of the efficiency-maximizing temperature. Membrane thickness, effective proton conductivity and catalyst-layer electrochemically active surface area (ECSA) are used as health states. Their baseline degradation coefficients are taken from separate published experiments and extrapolated in a reduced-order lifecycle scenario; temperature- and current-dependent degradation kinetics are not identified in the present study. In load-step simulations, heat feedforward reduces the peak temperature deviation from 1.29 to 0.19 °C and the settling time from 305 to 145 s. In a 1000-day variable-load simulation, the maximum instantaneous relative efficiency gain and lifecycle-average relative gain over a fixed 65 °C baseline are 15.82% and 2.03%, respectively. On an independent 48 h synthetic PV–wind-type benchmark sampled every 10 s, the RLS-assisted ESC achieves 78.8313% hydrogen-production load-weighted efficiency, compared with 78.3653% for the fixed-temperature baseline and 78.8319% for a same-gain full-health-information lookup-table reference. The 0.0006-percentage-point difference from the full-information reference is below the resolution justified by this single deterministic simulation and is not interpreted as a statistically significant advantage or disadvantage. One-factor sensitivity tests indicate that the ESC gain over the fixed-temperature baseline remains positive across the tested parameter ranges, while the small gap to the full-information reference is sensitive to controller and surrogate-model settings. The results therefore demonstrate the numerical feasibility of the integrated control architecture, while experimental durability, gas-crossover safety limits and probabilistic uncertainty remain to be established.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-11-26
DOI
https://doi.org/10.3390/en19235733
Primary Topic
Fuel Cells and Related Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Degradation-Aware Lifecycle Efficiency Modeling and Extremum-Seeking Control of Proton Exchange Membrane Water Electrolyzers

Jie Pan, Weipeng Zhao, Jie Chen, Xueying Gao et al.
Energies
Fuel Cells and Related Materials
article

Degradation-Aware Lifecycle Efficiency Modeling and Extremum-Seeking Control of Proton Exchange Membrane Water Electrolyzers

Jie Pan, Weipeng Zhao, Jie Chen, Xueying Gao, Jiacheng Ding, Jianbing Lü
article en

Abstract

This study develops and numerically assesses a degradation-aware, multirate operating framework for proton exchange membrane water electrolyzers (PEMWEs) under variable renewable-type loads. The contribution is not a new electrochemical constitutive law; rather, it is the explicit integration of (i) a health-state-dependent system-efficiency map, (ii) irreversible-heat feedforward compensation for fast electrothermal disturbances, and (iii) load-compensated extremum-seeking control (ESC) for slower tracking of the efficiency-maximizing temperature. Membrane thickness, effective proton conductivity and catalyst-layer electrochemically active surface area (ECSA) are used as health states. Their baseline degradation coefficients are taken from separate published experiments and extrapolated in a reduced-order lifecycle scenario; temperature- and current-dependent degradation kinetics are not identified in the present study. In load-step simulations, heat feedforward reduces the peak temperature deviation from 1.29 to 0.19 °C and the settling time from 305 to 145 s. In a 1000-day variable-load simulation, the maximum instantaneous relative efficiency gain and lifecycle-average relative gain over a fixed 65 °C baseline are 15.82% and 2.03%, respectively. On an independent 48 h synthetic PV–wind-type benchmark sampled every 10 s, the RLS-assisted ESC achieves 78.8313% hydrogen-production load-weighted efficiency, compared with 78.3653% for the fixed-temperature baseline and 78.8319% for a same-gain full-health-information lookup-table reference. The 0.0006-percentage-point difference from the full-information reference is below the resolution justified by this single deterministic simulation and is not interpreted as a statistically significant advantage or disadvantage. One-factor sensitivity tests indicate that the ESC gain over the fixed-temperature baseline remains positive across the tested parameter ranges, while the small gap to the full-information reference is sensitive to controller and surrogate-model settings. The results therefore demonstrate the numerical feasibility of the integrated control architecture, while experimental durability, gas-crossover safety limits and probabilistic uncertainty remain to be established.

EnergiesVol. 19(23)
Changji University (CN), Shanghai Dianji University (CN), Xinjiang University (CN)
Fuel Cells and Related Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon