Degradation-Aware Lifecycle Efficiency Modeling and Extremum-Seeking Control of Proton Exchange Membrane Water Electrolyzers
This study develops and numerically assesses a degradation-aware, multirate operating framework for proton exchange membrane water electrolyzers (PEMWEs) under variable renewable-type loads. The contribution is not a new electrochemical constitutive law; rather, it is the explicit integration of (i) a health-state-dependent system-efficiency map, (ii) irreversible-heat feedforward compensation for fast electrothermal disturbances, and (iii) load-compensated extremum-seeking control (ESC) for slower tracking of the efficiency-maximizing temperature. Membrane thickness, effective proton conductivity and catalyst-layer electrochemically active surface area (ECSA) are used as health states. Their baseline degradation coefficients are taken from separate published experiments and extrapolated in a reduced-order lifecycle scenario; temperature- and current-dependent degradation kinetics are not identified in the present study. In load-step simulations, heat feedforward reduces the peak temperature deviation from 1.29 to 0.19 °C and the settling time from 305 to 145 s. In a 1000-day variable-load simulation, the maximum instantaneous relative efficiency gain and lifecycle-average relative gain over a fixed 65 °C baseline are 15.82% and 2.03%, respectively. On an independent 48 h synthetic PV–wind-type benchmark sampled every 10 s, the RLS-assisted ESC achieves 78.8313% hydrogen-production load-weighted efficiency, compared with 78.3653% for the fixed-temperature baseline and 78.8319% for a same-gain full-health-information lookup-table reference. The 0.0006-percentage-point difference from the full-information reference is below the resolution justified by this single deterministic simulation and is not interpreted as a statistically significant advantage or disadvantage. One-factor sensitivity tests indicate that the ESC gain over the fixed-temperature baseline remains positive across the tested parameter ranges, while the small gap to the full-information reference is sensitive to controller and surrogate-model settings. The results therefore demonstrate the numerical feasibility of the integrated control architecture, while experimental durability, gas-crossover safety limits and probabilistic uncertainty remain to be established.
Authors
- Jie Pan
- Weipeng Zhao
- Jie Chen
- Xueying Gao
- Jiacheng Ding
- Jianbing Lü
Institutions
- Changji University (CN)
- Shanghai Dianji University (CN)
- Xinjiang University (CN)
Publication Details
- Journal
- Energies
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3390/en19235733
- Primary Topic
- Fuel Cells and Related Materials
- Type
- article
- Field-Weighted Citation Impact
- 0.00