A comparative study of polypropylene self-adhesive mesh (ProGrip) versus polypropylene mesh suture fixation in inguinal hernia repair

Background: Self-gripping mesh may simplify fixation during open inguinal hernia repair, potentially improving operative efficiency and postoperative recovery. Conventional suture fixation may contribute to postoperative tissue irritation. This study compared self-gripping polypropylene mesh with conventional sutured polypropylene mesh. Methods: This prospective, hospital-based study included 60 adults undergoing elective open Lichtenstein hernioplasty at GMERS Medical College, Vadodara. Participants were allocated by computer-generated block randomization to self-gripping ProGrip mesh (n=30) or conventional sutured mesh (n=30). Operative duration, postoperative visual analogue scale (VAS) pain scores, hospital stay, return to normal activities, complications, and recurrence were evaluated over three months. Results: Mean operative duration was shorter with self-gripping mesh (56.40±8.70 versus 68.90±10.20 minutes; p<0.001). At 24 hours, mean VAS pain scores were lower (4.83±1.29 versus 6.23±1.04; p<0.001), with significant differences persisting through one month but not at three months (p=0.486). Pain reduction was also significant at 48 hours (3.93 versus 5.00; p<0.001), 14 days (2.60 versus 3.40; p=0.010), and one month (0.70 versus 1.30; p=0.011). Return to normal activities was faster (1.30±0.47 versus 3.50±0.63 days; p<0.001), and seroma was less frequent (6.7% versus 30.0%; p=0.020). However, hospital stay was slightly longer (2.23±0.43 versus 1.93±0.69 days; p=0.048). Surgical-site infection, scrotal swelling, and recurrence did not differ significantly. No recurrence occurred with self-gripping mesh, compared with one recurrence in the conventional mesh group during follow-up. Conclusions: Self-gripping polypropylene mesh reduced operative time, early pain, and seroma formation and facilitated earlier return to activities. Longer follow-up and larger studies are necessary to assess sustained benefits and recurrence.

Authors

Publication Details

Journal
International Surgery Journal
Published
2026-11-25
DOI
https://doi.org/10.18203/2349-2902.isj20264360
Primary Topic
Hernia repair and management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A comparative study of polypropylene self-adhesive mesh (ProGrip) versus polypropylene mesh suture fixation in inguinal hernia repair

Amul N Bhedi, Priyanshi K. Langalia, Bhavin H. Patel, Gaurang K. Raiyani
International Surgery Journal
Hernia repair and management
article

A comparative study of polypropylene self-adhesive mesh (ProGrip) versus polypropylene mesh suture fixation in inguinal hernia repair

Amul N Bhedi, Priyanshi K. Langalia, Bhavin H. Patel, Gaurang K. Raiyani
article en

Abstract

Background: Self-gripping mesh may simplify fixation during open inguinal hernia repair, potentially improving operative efficiency and postoperative recovery. Conventional suture fixation may contribute to postoperative tissue irritation. This study compared self-gripping polypropylene mesh with conventional sutured polypropylene mesh. Methods: This prospective, hospital-based study included 60 adults undergoing elective open Lichtenstein hernioplasty at GMERS Medical College, Vadodara. Participants were allocated by computer-generated block randomization to self-gripping ProGrip mesh (n=30) or conventional sutured mesh (n=30). Operative duration, postoperative visual analogue scale (VAS) pain scores, hospital stay, return to normal activities, complications, and recurrence were evaluated over three months. Results: Mean operative duration was shorter with self-gripping mesh (56.40±8.70 versus 68.90±10.20 minutes; p<0.001). At 24 hours, mean VAS pain scores were lower (4.83±1.29 versus 6.23±1.04; p<0.001), with significant differences persisting through one month but not at three months (p=0.486). Pain reduction was also significant at 48 hours (3.93 versus 5.00; p<0.001), 14 days (2.60 versus 3.40; p=0.010), and one month (0.70 versus 1.30; p=0.011). Return to normal activities was faster (1.30±0.47 versus 3.50±0.63 days; p<0.001), and seroma was less frequent (6.7% versus 30.0%; p=0.020). However, hospital stay was slightly longer (2.23±0.43 versus 1.93±0.69 days; p=0.048). Surgical-site infection, scrotal swelling, and recurrence did not differ significantly. No recurrence occurred with self-gripping mesh, compared with one recurrence in the conventional mesh group during follow-up. Conclusions: Self-gripping polypropylene mesh reduced operative time, early pain, and seroma formation and facilitated earlier return to activities. Longer follow-up and larger studies are necessary to assess sustained benefits and recurrence.

International Surgery JournalVol. 13(12)
Hernia repair and management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon