Safety and Efficacy of Linear Ablation for Peri‐Mitral Annular Atrial Flutter Using the Pentaspline Pulse Field Ablation Catheter

BACKGROUND: Despite widespread use of the pentaspline pulse field ablation (PFA) catheter to treat atrial fibrillation, there is limited data supporting its feasibility, safety, and effectiveness in creating linear lesions to treat peri-mitral atrial flutter (AFL). OBJECTIVE: To assess the safety and efficacy of using the pentaspline PFA catheter to treat peri-mitral AFL. METHODS: We performed a single-center retrospective review of consecutive patients receiving catheter ablation using the pentaspline PFA catheter to treat peri-mitral macroreentrant AFL. RESULTS: A total of 80 patients underwent catheter ablation for clinical peri-mitral AFL. Ablation was guided by electroanatomic mapping in all patients. AFL was treated with a lateral mitral line in 38 patients (47.5%), an anteroseptal mitral line in 31 patients (38.8%), a septal mitral line in 6 patients (7.5%), and an anterolateral mitral line in 5 patients (6.3%). Acute procedural success was achieved in 70 patients (87.5%) using the pentaspline catheter; the remaining 10 patients (12.5%) required additional radiofrequency ablation to achieve procedural success. Acute complications occurred in 4 (5.0%) patients: 2 (2.5%) patients sustained electrical isolation of the left atrial appendage, 1 (1.3%) had transient hematuria, and 1 (1.3%) had pericarditis. After a median follow-up of 322 days (IQR 192-432), 42 patients (52.5%) had recurrent AFL. Of these patients, 26 patients underwent a repeat ablation procedure-all demonstrated electrical breakthrough across the prior mitral line. CONCLUSIONS: While the pentaspline catheter can achieve acute procedural success when treating peri-mitral AFL with linear ablation of the mitral annulus, the long-term efficacy of this treatment strategy is modest.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Electrophysiology
Published
2026-11-25
DOI
https://doi.org/10.1111/jce.70569
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Safety and Efficacy of Linear Ablation for Peri‐Mitral Annular Atrial Flutter Using the Pentaspline Pulse Field Ablation Catheter

Scott Grubman, Marc A. Miller, Jacob Sam Koruth, Srinivas Rao Dukkipati et al.
Journal of Cardiovascular Electrophysiology
Cardiac Arrhythmias and Treatments
article

Safety and Efficacy of Linear Ablation for Peri‐Mitral Annular Atrial Flutter Using the Pentaspline Pulse Field Ablation Catheter

Scott Grubman, Marc A. Miller, Jacob Sam Koruth, Srinivas Rao Dukkipati, Connor P. Oates, William Whang, Daniel Ross Musikantow, Vivek Yerrapu Reddy, Joshua M. Lampert, Mohit K. Turagam
article en

Abstract

BACKGROUND: Despite widespread use of the pentaspline pulse field ablation (PFA) catheter to treat atrial fibrillation, there is limited data supporting its feasibility, safety, and effectiveness in creating linear lesions to treat peri-mitral atrial flutter (AFL). OBJECTIVE: To assess the safety and efficacy of using the pentaspline PFA catheter to treat peri-mitral AFL. METHODS: We performed a single-center retrospective review of consecutive patients receiving catheter ablation using the pentaspline PFA catheter to treat peri-mitral macroreentrant AFL. RESULTS: A total of 80 patients underwent catheter ablation for clinical peri-mitral AFL. Ablation was guided by electroanatomic mapping in all patients. AFL was treated with a lateral mitral line in 38 patients (47.5%), an anteroseptal mitral line in 31 patients (38.8%), a septal mitral line in 6 patients (7.5%), and an anterolateral mitral line in 5 patients (6.3%). Acute procedural success was achieved in 70 patients (87.5%) using the pentaspline catheter; the remaining 10 patients (12.5%) required additional radiofrequency ablation to achieve procedural success. Acute complications occurred in 4 (5.0%) patients: 2 (2.5%) patients sustained electrical isolation of the left atrial appendage, 1 (1.3%) had transient hematuria, and 1 (1.3%) had pericarditis. After a median follow-up of 322 days (IQR 192-432), 42 patients (52.5%) had recurrent AFL. Of these patients, 26 patients underwent a repeat ablation procedure-all demonstrated electrical breakthrough across the prior mitral line. CONCLUSIONS: While the pentaspline catheter can achieve acute procedural success when treating peri-mitral AFL with linear ablation of the mitral annulus, the long-term efficacy of this treatment strategy is modest.

Journal of Cardiovascular Electrophysiology
Roper St. Francis Healthcare (US), Icahn School of Medicine at Mount Sinai (US)
Cardiac Arrhythmias and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon