Comparative Outcomes of Robotic‐Assisted Versus Manual Percutaneous Coronary Intervention Using a Four‐Channel Robotic Platform
BACKGROUND: Robotic-assisted PCI (R-PCI) reduces operator radiation and physical workload. Existing platforms operate a single guidewire at a time, and comparative data on R-PCI in situations that require a second wire for side-branch protection are lacking. AIMS: We evaluated the feasibility and safety of R-PCI using a four-channel platform, compared with manual PCI (M-PCI), in elective single-vessel PCI. METHODS: In this single-center pilot study, 40 patients were enrolled (M-PCI, n = 30; R-PCI, n = 10). The four-channel architecture enabled remote dual-wire side-branch protection in 3 of the 10 R-PCI cases. Procedure time, operator and patient radiation, contrast volume, NASA Task Load Index (NASA-TLX), and CK-MB and troponin-I at 6 and 12 h were recorded. Pre-specified per-minute rates were calculated. Groups were compared with the Mann-Whitney U test. RESULTS: Technical and clinical success were 100%, with no conversion to manual operation and no device-related adverse events. R-PCI procedures were longer than M-PCI (33.3 ± 11.4 vs. 26.0 ± 15.1 min; p = 0.027). Operator radiation outside the lead apron was 92% lower with R-PCI (p < 0.001). Cumulative patient radiation and contrast did not differ significantly, but per-minute rates were lower for contrast (-43%; p < 0.001), DAP (-35%; p = 0.002), and air kerma (-42%; p < 0.001). Operator workload (NASA-TLX) was 68% lower (p = 0.002). Post-procedural CK-MB was lower at 6 and 12 h (p = 0.049 and 0.044), and troponin-I followed the same direction without reaching significance. CONCLUSIONS: R-PCI with a four-channel platform was feasible and safe, with lower operator radiation, lower workload, and lower per-minute patient exposure, and allowed remote dual-wire side-branch protection. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06735716 (LNR-AVIARMX2-I02). Registered prior to first patient enrollment.
Authors
- Yeon-Jik Choi (ORCID: https://orcid.org/0000-0003-0720-1449)
- Jeong‐Eun Yi (ORCID: https://orcid.org/0000-0003-2614-6983)
- Osung Kwon (ORCID: https://orcid.org/0000-0001-6857-8632)
- Suk Min Seo (ORCID: https://orcid.org/0000-0003-2424-5275)
- Daeung Ohn
- Sook Jung Kim
- Junghoon Lee (ORCID: https://orcid.org/0000-0003-0617-3116)
- Sung-Won Jang (ORCID: https://orcid.org/0000-0001-5272-0665)
Institutions
- The Catholic University of Korea Eunpyeong St. Mary's Hospital (KR)
- Catholic University of Korea (KR)
Publication Details
- Journal
- Catheterization and Cardiovascular Interventions
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1002/ccd.71035
- Primary Topic
- Coronary Interventions and Diagnostics
- Type
- article
- Field-Weighted Citation Impact
- 0.00