Comparative Outcomes of Robotic‐Assisted Versus Manual Percutaneous Coronary Intervention Using a Four‐Channel Robotic Platform

BACKGROUND: Robotic-assisted PCI (R-PCI) reduces operator radiation and physical workload. Existing platforms operate a single guidewire at a time, and comparative data on R-PCI in situations that require a second wire for side-branch protection are lacking. AIMS: We evaluated the feasibility and safety of R-PCI using a four-channel platform, compared with manual PCI (M-PCI), in elective single-vessel PCI. METHODS: In this single-center pilot study, 40 patients were enrolled (M-PCI, n = 30; R-PCI, n = 10). The four-channel architecture enabled remote dual-wire side-branch protection in 3 of the 10 R-PCI cases. Procedure time, operator and patient radiation, contrast volume, NASA Task Load Index (NASA-TLX), and CK-MB and troponin-I at 6 and 12 h were recorded. Pre-specified per-minute rates were calculated. Groups were compared with the Mann-Whitney U test. RESULTS: Technical and clinical success were 100%, with no conversion to manual operation and no device-related adverse events. R-PCI procedures were longer than M-PCI (33.3 ± 11.4 vs. 26.0 ± 15.1 min; p = 0.027). Operator radiation outside the lead apron was 92% lower with R-PCI (p < 0.001). Cumulative patient radiation and contrast did not differ significantly, but per-minute rates were lower for contrast (-43%; p < 0.001), DAP (-35%; p = 0.002), and air kerma (-42%; p < 0.001). Operator workload (NASA-TLX) was 68% lower (p = 0.002). Post-procedural CK-MB was lower at 6 and 12 h (p = 0.049 and 0.044), and troponin-I followed the same direction without reaching significance. CONCLUSIONS: R-PCI with a four-channel platform was feasible and safe, with lower operator radiation, lower workload, and lower per-minute patient exposure, and allowed remote dual-wire side-branch protection. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06735716 (LNR-AVIARMX2-I02). Registered prior to first patient enrollment.

Authors

Institutions

Publication Details

Journal
Catheterization and Cardiovascular Interventions
Published
2026-11-25
DOI
https://doi.org/10.1002/ccd.71035
Primary Topic
Coronary Interventions and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparative Outcomes of Robotic‐Assisted Versus Manual Percutaneous Coronary Intervention Using a Four‐Channel Robotic Platform

Yeon-Jik Choi, Jeong‐Eun Yi, Osung Kwon, Suk Min Seo et al.
Catheterization and Cardiovascular Interventions
Coronary Interventions and Diagnostics
article

Comparative Outcomes of Robotic‐Assisted Versus Manual Percutaneous Coronary Intervention Using a Four‐Channel Robotic Platform

Yeon-Jik Choi, Jeong‐Eun Yi, Osung Kwon, Suk Min Seo, Daeung Ohn, Sook Jung Kim, Junghoon Lee, Sung-Won Jang
article en

Abstract

BACKGROUND: Robotic-assisted PCI (R-PCI) reduces operator radiation and physical workload. Existing platforms operate a single guidewire at a time, and comparative data on R-PCI in situations that require a second wire for side-branch protection are lacking. AIMS: We evaluated the feasibility and safety of R-PCI using a four-channel platform, compared with manual PCI (M-PCI), in elective single-vessel PCI. METHODS: In this single-center pilot study, 40 patients were enrolled (M-PCI, n = 30; R-PCI, n = 10). The four-channel architecture enabled remote dual-wire side-branch protection in 3 of the 10 R-PCI cases. Procedure time, operator and patient radiation, contrast volume, NASA Task Load Index (NASA-TLX), and CK-MB and troponin-I at 6 and 12 h were recorded. Pre-specified per-minute rates were calculated. Groups were compared with the Mann-Whitney U test. RESULTS: Technical and clinical success were 100%, with no conversion to manual operation and no device-related adverse events. R-PCI procedures were longer than M-PCI (33.3 ± 11.4 vs. 26.0 ± 15.1 min; p = 0.027). Operator radiation outside the lead apron was 92% lower with R-PCI (p < 0.001). Cumulative patient radiation and contrast did not differ significantly, but per-minute rates were lower for contrast (-43%; p < 0.001), DAP (-35%; p = 0.002), and air kerma (-42%; p < 0.001). Operator workload (NASA-TLX) was 68% lower (p = 0.002). Post-procedural CK-MB was lower at 6 and 12 h (p = 0.049 and 0.044), and troponin-I followed the same direction without reaching significance. CONCLUSIONS: R-PCI with a four-channel platform was feasible and safe, with lower operator radiation, lower workload, and lower per-minute patient exposure, and allowed remote dual-wire side-branch protection. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT06735716 (LNR-AVIARMX2-I02). Registered prior to first patient enrollment.

Catheterization and Cardiovascular Interventions
The Catholic University of Korea Eunpyeong St. Mary's Hospital (KR), Catholic University of Korea (KR)
Coronary Interventions and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.