Real‐Time HIL Validation of a Model‐Free Online PSO‐Adaptive PI Controller for Battery–Supercapacitor DC‐Bus Voltage Regulation

Battery–supercapacitor hybrid energy storage systems are widely used to improve DC‐bus stability under fast load‐current variations. In such systems, the battery supplies the low‐frequency energy demand, while the supercapacitor compensates rapid transient components. However, fixed‐gain PI voltage controllers may lose performance when the operating point, storage states, converter conditions, or load‐current demand vary during operation. This paper proposes a model‐free online particle swarm optimization (PSO) tuner for adaptive PI regulation of the DC‐bus voltage in a battery–supercapacitor hybrid storage system. The proposed method does not require an analytical model of the battery, supercapacitor, bidirectional converters, DC‐link capacitance, or load. Each particle represents a candidate pair of proportional and integral gains, and its quality is evaluated from the measured DC‐bus voltage error and internally computed PI quantities over a short time window. The fitness function combines the squared tracking error, error variation, error‐worsening penalty, weak control‐effort penalty, and saturation penalty. To improve real‐time safety, each tested particle is blended with the current global‐best gain vector before being applied to the controller, while a stabilizing PI gain pair is preserved as an elitist fallback particle. The proposed controller is integrated with a frequency‐separation energy management system and validated through real‐time hardware‐in‐the‐loop implementation using separated control‐side and plant‐side execution. Experimental results under a 24 s load‐current profile show that the proposed PSO‐adaptive PI controller reduces the RMSE from 1.38 V to 0.83 V, the maximum voltage error from 11.39 V to 4.71 V, and the maximum voltage deviation from 9.49% to 3.93% compared with a Lyapunov‐guided fixed‐gain PI reference. For the examined load profile, the results support the practical feasibility of measured‐error‐based online PI tuning in the tested hardware‐in‐the‐loop configuration.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2026-11-26
DOI
https://doi.org/10.1002/ese3.70712
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Real‐Time HIL Validation of a Model‐Free Online PSO‐Adaptive PI Controller for Battery–Supercapacitor DC‐Bus Voltage Regulation

Omar Charrouf, Faiza Zaamoune, Mehmet Yavuz, Mohamed Fadi Kethiri
Energy Science & Engineering
Microgrid Control and Optimization
article

Real‐Time HIL Validation of a Model‐Free Online PSO‐Adaptive PI Controller for Battery–Supercapacitor DC‐Bus Voltage Regulation

Omar Charrouf, Faiza Zaamoune, Mehmet Yavuz, Mohamed Fadi Kethiri
article en

Abstract

Battery–supercapacitor hybrid energy storage systems are widely used to improve DC‐bus stability under fast load‐current variations. In such systems, the battery supplies the low‐frequency energy demand, while the supercapacitor compensates rapid transient components. However, fixed‐gain PI voltage controllers may lose performance when the operating point, storage states, converter conditions, or load‐current demand vary during operation. This paper proposes a model‐free online particle swarm optimization (PSO) tuner for adaptive PI regulation of the DC‐bus voltage in a battery–supercapacitor hybrid storage system. The proposed method does not require an analytical model of the battery, supercapacitor, bidirectional converters, DC‐link capacitance, or load. Each particle represents a candidate pair of proportional and integral gains, and its quality is evaluated from the measured DC‐bus voltage error and internally computed PI quantities over a short time window. The fitness function combines the squared tracking error, error variation, error‐worsening penalty, weak control‐effort penalty, and saturation penalty. To improve real‐time safety, each tested particle is blended with the current global‐best gain vector before being applied to the controller, while a stabilizing PI gain pair is preserved as an elitist fallback particle. The proposed controller is integrated with a frequency‐separation energy management system and validated through real‐time hardware‐in‐the‐loop implementation using separated control‐side and plant‐side execution. Experimental results under a 24 s load‐current profile show that the proposed PSO‐adaptive PI controller reduces the RMSE from 1.38 V to 0.83 V, the maximum voltage error from 11.39 V to 4.71 V, and the maximum voltage deviation from 9.49% to 3.93% compared with a Lyapunov‐guided fixed‐gain PI reference. For the examined load profile, the results support the practical feasibility of measured‐error‐based online PI tuning in the tested hardware‐in‐the‐loop configuration.

Energy Science & Engineering
University of Biskra (DZ), Necmettin Erbakan University (TR), Kyrgyz-Türkish Manas Üniversity (KG)
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon