Lung cancer stem-like cells show no shared Raman signature of adipogenesis

Driving cancer stem-like cells into a terminal lineage is one strategy for differentiation therapy, and labelfree Raman spectroscopy is often proposed as a way to follow that conversion in single living cells. We reanalysed a public set of 214 single-cell Raman spectra from CD133+/CD44+/CD24- lung cancer stemlike cells of three non-small cell lung cancer patients, kept in adipogenic or control medium and measured after 7 and 14 days, comparing the two media only within one donor and one measurement session. Most of the fingerprint variance came from a single sharp-band component, X (bands at 680, 747, 952, 1143, 1338, 1449 and 1525 cm-1), which was present in both media, varied as one species (ρ = 0.96), was unrelated to the cells’ protein and C–H content (|ρ| ≤ 0.17), exceeded the phenylalanine band in 82% of cells and defined the first principal component of every pairwise model. After X was masked or subtracted, induced and control cells remained separable within some sessions, most robustly in one donor (balanced accuracy 0.66–0.80, permutation P ≤ 0.035). The direction of that difference, however, was not shared. Inter-donor correlations of the difference spectra (−0.55 to 0.40; mean −0.11) fell within a label-permutation null, a model trained on two donors classified the third at chance, and neither the ester carbonyl nor the CH2 stretching band showed a consistent lipid gain. A power simulation showed that a common signature as large as the observed within-session differences would have raised the mean inter-donor correlation to about 0.3 and been detected. The two time points were also stored on wavenumber axes 8–13 cm-1 apart. Over 14 days, adipogenic induction left no common Raman signature in these cells; the response was specific to each donor, and much of the spectral variance came from a component of unresolved origin.

Authors

Institutions

Publication Details

Journal
ChemRxiv
Published
2026-11-26
DOI
https://doi.org/10.26434/chemrxiv.15012836/v1
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Lung cancer stem-like cells show no shared Raman signature of adipogenesis

Seyedeh Rahemeh Amiri
ChemRxiv
Spectroscopy Techniques in Biomedical and Chemical Research
preprint

Lung cancer stem-like cells show no shared Raman signature of adipogenesis

Seyedeh Rahemeh Amiri
preprint en

Abstract

Driving cancer stem-like cells into a terminal lineage is one strategy for differentiation therapy, and labelfree Raman spectroscopy is often proposed as a way to follow that conversion in single living cells. We reanalysed a public set of 214 single-cell Raman spectra from CD133+/CD44+/CD24- lung cancer stemlike cells of three non-small cell lung cancer patients, kept in adipogenic or control medium and measured after 7 and 14 days, comparing the two media only within one donor and one measurement session. Most of the fingerprint variance came from a single sharp-band component, X (bands at 680, 747, 952, 1143, 1338, 1449 and 1525 cm-1), which was present in both media, varied as one species (ρ = 0.96), was unrelated to the cells’ protein and C–H content (|ρ| ≤ 0.17), exceeded the phenylalanine band in 82% of cells and defined the first principal component of every pairwise model. After X was masked or subtracted, induced and control cells remained separable within some sessions, most robustly in one donor (balanced accuracy 0.66–0.80, permutation P ≤ 0.035). The direction of that difference, however, was not shared. Inter-donor correlations of the difference spectra (−0.55 to 0.40; mean −0.11) fell within a label-permutation null, a model trained on two donors classified the third at chance, and neither the ester carbonyl nor the CH2 stretching band showed a consistent lipid gain. A power simulation showed that a common signature as large as the observed within-session differences would have raised the mean inter-donor correlation to about 0.3 and been detected. The two time points were also stored on wavenumber axes 8–13 cm-1 apart. Over 14 days, adipogenic induction left no common Raman signature in these cells; the response was specific to each donor, and much of the spectral variance came from a component of unresolved origin.

ChemRxiv
University at Albany, State University of New York (US)
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon