Investigation of the Rotor‐Stator Interaction on the Energy Loss in Pump Working Conditions of Bulb Turbine Unit for Tidal Power Stations

To improve the performance of large bulb turbine unit at pump working conditions, it is important to identify the primary sources of power loss. In this study, the power loss in the various flow rate conditions of a reduced scale model have been numerically investigated based on the energy balance equation and the pressure fluctuations solving the transient flow with the SST k‐ω turbulence model in order to characterize the effects of the rotor‐stator interaction (RSI). The numerical model has been validated comparing the predicted unit performance with experimental results showing a good agreement. The power loss in the rib, impeller and diffuser domains present the same trends as the total pressure loss. Moreover, the most significant sources of power loss are associated with the Reynolds stress and wall friction. The energy balance equation has permitted to identify the typical vortex structures in the regions with larger power loss. The time‐frequency characteristics of power loss in the energy balance equation reveals that under steady flow rate conditions, the power loss in the rib is mainly caused by the RSI between the rib and the impeller, the power loss in the impeller is affected by the impeller rotation and the number of ribs, while the power loss in the diffuser is mainly affected by the impeller rotation, and the dominant frequency of power loss is 1 f r or 4 f r. At the same time, it is found that the power loss of each sub‐item only fluctuates within a small range over time. The pressure fluctuation characteristics of the monitoring points at the rotor‐stator interface also verify the power loss characteristics of the flow field.

Authors

Institutions

Publication Details

Journal
Energy Science & Engineering
Published
2026-11-26
DOI
https://doi.org/10.1002/ese3.70711
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Investigation of the Rotor‐Stator Interaction on the Energy Loss in Pump Working Conditions of Bulb Turbine Unit for Tidal Power Stations

Qiang Pan, Xavier Escaler, Naijiang Xu, Longyue Sun et al.
Energy Science & Engineering
Cavitation Phenomena in Pumps
article

Investigation of the Rotor‐Stator Interaction on the Energy Loss in Pump Working Conditions of Bulb Turbine Unit for Tidal Power Stations

Qiang Pan, Xavier Escaler, Naijiang Xu, Longyue Sun, Zhaoyu Lv, Desheng Zhang
article en

Abstract

To improve the performance of large bulb turbine unit at pump working conditions, it is important to identify the primary sources of power loss. In this study, the power loss in the various flow rate conditions of a reduced scale model have been numerically investigated based on the energy balance equation and the pressure fluctuations solving the transient flow with the SST k‐ω turbulence model in order to characterize the effects of the rotor‐stator interaction (RSI). The numerical model has been validated comparing the predicted unit performance with experimental results showing a good agreement. The power loss in the rib, impeller and diffuser domains present the same trends as the total pressure loss. Moreover, the most significant sources of power loss are associated with the Reynolds stress and wall friction. The energy balance equation has permitted to identify the typical vortex structures in the regions with larger power loss. The time‐frequency characteristics of power loss in the energy balance equation reveals that under steady flow rate conditions, the power loss in the rib is mainly caused by the RSI between the rib and the impeller, the power loss in the impeller is affected by the impeller rotation and the number of ribs, while the power loss in the diffuser is mainly affected by the impeller rotation, and the dominant frequency of power loss is 1 f r or 4 f r. At the same time, it is found that the power loss of each sub‐item only fluctuates within a small range over time. The pressure fluctuation characteristics of the monitoring points at the rotor‐stator interface also verify the power loss characteristics of the flow field.

Energy Science & Engineering
Jiangsu University (CN), North China University of Water Resources and Electric Power (CN), Universitat Politècnica de Catalunya (ES)
Cavitation Phenomena in Pumps
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon