Molecular Quantum Sensors Measure Temperature Differences Inside Cancer Cell Nuclei

The researchers developed molecular quantum nanosensors (MoQNs) based on the electron spins of pentacene molecules and demonstrated optical spin readout and coherent quantum control inside living cells. Compared with similarly sized nanodiamonds, the molecular spin sensors showed more uniform resonance frequencies. Deuterating pentacene further reduced hyperfine-related spectral complexity, enabling spatially resolved absolute temperature measurements in the cytoplasm and nuclei of cancer cells. Local temperature differences of approximately 1°C were observed at some locations within cell nuclei, while hydrogen peroxide treatment altered radical-related spin relaxation signals. However, the biological origins and generality of these intranuclear temperature differences remain uncertain. [Quantum Biology Society] The temperature inside a living cell cannot always be represented by a single number. Metabolism and molecular reactions occur under different conditions in the cytoplasm, nucleus, and various organelles. Yet accurately measuring absolute temperature within these tiny intracellular regions remains technically challenging. Existing quantum nanosensors, such as nitrogen-vacancy (NV) centers in nanodiamonds, can use electron spins to detect temperature and magnetic noise. However, the process of creating atomic defects in diamond can introduce material heterogeneity, causing individual sensors to exhibit different resonance frequencies. When two sensors at different intracellular locations produce different readings, researchers must determine whether the difference reflects a genuine temperature variation or a difference between the sensors themselves. Hitoshi Ishiwata of Japan's National Institutes for Quantum Science and Technology (QST) and Chiba University, together with Jiarui Song of Kyushu University, Yoko Shigeno of QST, and Koki Nishimura and Nobuhiro Yanai of the University of Tokyo, developed molecular quantum nanosensors (MoQNs) that use the electron spins of chemically defined molecules rather than defects in diamond. Ishiwata and Yanai served as corresponding authors, while Ishiwata and Song contributed equally as co-first authors. The study was published on April 29, 2026, in Science Advances, Volume 12, Issue 18, Article eaeb5422. On October 20, Nature Reviews Physics also featured the technology in a separate research highlight titled "Taking the temperature of a cancer cell." The researchers demonstrated quantum spin control inside living cells and used their sensors to measure spatial variations in absolute temperature and radical-related signals within cancer cells, including their nuclei. ■ Replacing Atomic Defects in Diamond with Chemically Defined Pentacene Molecules In conventional NV nanodiamonds, the sensing element is a crystal defect consisting of a nitrogen atom adjacent to a vacant carbon site in the diamond lattice. The new MoQN platform uses a different approach. Its quantum sensing element is pentacene, an organic molecule with well-defined electronic spin properties. The researchers incorporated a small amount of pentacene into para-terphenyl nanocrystals and coated the particles with Pluronic F-127, a biocompatible surfactant that improves their dispersibility in water. They fabricated two nominal particle sizes, approximately 200 nm and 500 nm, designated MoQN200 and MoQN500. These values refer to the dimensions of the sensor particles. They should not be confused with the spatial resolution achieved when mapping intracellular temperature. When pentacene absorbs light, it can enter an excited triplet state. This state contains electron-spin sublevels with different energies. Applying microwaves at an appropriate frequency changes the populations of these sublevels, producing a corresponding change in fluorescence. The researchers measured this response using optically detected magnetic resonance (ODMR). The principle is somewhat similar to tuning a radio receiver to a particular frequency. By identifying the resonance frequency of the electron spins, researchers can obtain information about the local environment surrounding the sensor. One of the first important results was the uniformity of resonance frequencies among individual particles. For approximately 200 nm MoQNs, the standard deviation of ODMR resonance positions was ±0.13 MHz, compared with ±0.45 MHz for similarly sized nanodiamonds containing NV centers. For the approximately 500 nm particles, the corresponding values were ±0.18 MHz for MoQNs and ±2.85 MHz for nanodiamonds. In the 200 nm comparison, the variation in resonance positions was therefore reduced by more than threefold. This greater uniformity matters because absolute temperature measurement requires knowing the relationship between a sensor's resonance frequency and temperature. If different particles have substantially different baseline resonance frequencies, a frequency difference between two intracellular locations may be difficult to interpret. Using molecular spin centers with more uniform resonance properties reduces this source of uncertainty. However, the study does not show that MoQNs outperform nanodiamonds in every aspect of quantum sensing. The average continuous-wave ODMR contrast was approximately 2% for MoQNs, whereas the 200 nm and 500 nm nanodiamonds used for comparison exhibited contrasts of approximately 6% and 3%, respectively. The central advantage of the molecular platform is therefore not universally stronger ODMR contrast, but the combination of resonance-frequency uniformity and the ability to chemically modify the molecular spin environment through isotope substitution. ■ Coherent Spin Control Remained Possible Inside Living Cells A molecular quantum sensor that functions in a laboratory sample will not necessarily perform equally well inside a living cell. The intracellular environment contains water, ions, proteins, and numerous other molecules that can affect spin behavior. Introducing nanoparticles or exposing cells to light and microwaves may also cause cellular stress or damage. The researchers therefore first examined whether MoQNs could be introduced into living cells without substantially disrupting cell viability and function under the tested conditions. They delivered MoQNs into Hepa1-6 cells, a mouse liver cancer cell line, and assessed plasma membrane integrity, apoptosis-associated caspase activity, metabolic reducing activity, and cell-cycle progression through DNA synthesis. The assays did not detect substantial impairment under the experimental conditions. Comparable results were obtained in HEK-293H and HepG2 cells. The researchers also reported preserved cell viability during observations extending to approximately 72 hours. These findings support the biological compatibility of MoQNs under the conditions examined, although they do not establish long-term safety across all cell types or exposure conditions. The researchers then used confocal microscopy to locate individual MoQN particles inside living cells and measure their spin properties. Continuous-wave ODMR measurements produced a contrast of approximately 1.5% within cells. They also demonstrated coherent manipulation of the electron spins by applying microwave pulses and observing Rabi oscillations, with a contrast of approximately 3%. The intracellular spin-lattice relaxation time, T1, was approximately 75 μs, while the spin coherence time, T2, measured through spin-echo experiments, was on the order of 1 μs. These results establish that MoQNs do more than function as ordinary fluorescent labels. Even inside living cells, their electron-spin states can be read optically and manipulated coherently using microwave pulses. An important conceptual distinction is necessary, however. Demonstrating coherent spin control inside a living cell does not mean that the cell's biological functions themselves rely on quantum coherence. In this experiment, the quantum state belongs to a sensor introduced by the researchers. Quantum coherence is the operating principle of the measurement device, not a demonstrated mechanism used by the cell to perform its physiological functions. ■ Deuterating Pentacene Improved the Precision of the Molecular Thermometer For a quantum sensor to measure absolute temperature, researchers must first establish how its resonance frequency changes with temperature. In MoQNs, temperature-dependent changes in the surrounding para-terphenyl crystal affect the zero-field splitting parameters of the pentacene triplet state. These changes shift the ODMR resonance frequency, providing a basis for temperature measurement. However, hyperfine interactions between electron spins and nearby hydrogen nuclear spins can create additional spectral components, making the resonance signal more complicated to analyze. The researchers addressed this problem through molecular isotope engineering. They replaced hydrogen atoms in pentacene with deuterium, a heavier isotope of hydrogen, creating deuterated molecular quantum nanosensors, or dMoQNs. Deuteration modifies the interactions between electron spins and surrounding nuclear spins, suppressing the hyperfine-related spectral complexity that can interfere with precise resonance-frequency measurements. Combined with the relatively uniform resonance frequencies already achieved in MoQNs, this chemical modification allowed the researchers to convert the resonance positions of individual particles into absolute temperature readings more reliably. In temperature calibration experiments outside cells, the ODMR frequency shifted by 102.4 ± 7.87 kHz/K. Inside living cells, the measured temperature coefficient was 102.3 ± 3.81 kHz/K. The close agreement between these two values supports the use of dMoQNs for temperature measurements in biological environments. The researchers also tested whether changes in the surrounding chemical environment could si

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24548113
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Molecular Quantum Sensors Measure Temperature Differences Inside Cancer Cell Nuclei

inquantio
Zenodo (CERN European Organization for Nuclear Research)
Diamond and Carbon-based Materials Research
article

Molecular Quantum Sensors Measure Temperature Differences Inside Cancer Cell Nuclei

inquantio
article en

Abstract

The researchers developed molecular quantum nanosensors (MoQNs) based on the electron spins of pentacene molecules and demonstrated optical spin readout and coherent quantum control inside living cells. Compared with similarly sized nanodiamonds, the molecular spin sensors showed more uniform resonance frequencies. Deuterating pentacene further reduced hyperfine-related spectral complexity, enabling spatially resolved absolute temperature measurements in the cytoplasm and nuclei of cancer cells. Local temperature differences of approximately 1°C were observed at some locations within cell nuclei, while hydrogen peroxide treatment altered radical-related spin relaxation signals. However, the biological origins and generality of these intranuclear temperature differences remain uncertain. [Quantum Biology Society] The temperature inside a living cell cannot always be represented by a single number. Metabolism and molecular reactions occur under different conditions in the cytoplasm, nucleus, and various organelles. Yet accurately measuring absolute temperature within these tiny intracellular regions remains technically challenging. Existing quantum nanosensors, such as nitrogen-vacancy (NV) centers in nanodiamonds, can use electron spins to detect temperature and magnetic noise. However, the process of creating atomic defects in diamond can introduce material heterogeneity, causing individual sensors to exhibit different resonance frequencies. When two sensors at different intracellular locations produce different readings, researchers must determine whether the difference reflects a genuine temperature variation or a difference between the sensors themselves. Hitoshi Ishiwata of Japan's National Institutes for Quantum Science and Technology (QST) and Chiba University, together with Jiarui Song of Kyushu University, Yoko Shigeno of QST, and Koki Nishimura and Nobuhiro Yanai of the University of Tokyo, developed molecular quantum nanosensors (MoQNs) that use the electron spins of chemically defined molecules rather than defects in diamond. Ishiwata and Yanai served as corresponding authors, while Ishiwata and Song contributed equally as co-first authors. The study was published on April 29, 2026, in Science Advances, Volume 12, Issue 18, Article eaeb5422. On October 20, Nature Reviews Physics also featured the technology in a separate research highlight titled "Taking the temperature of a cancer cell." The researchers demonstrated quantum spin control inside living cells and used their sensors to measure spatial variations in absolute temperature and radical-related signals within cancer cells, including their nuclei. ■ Replacing Atomic Defects in Diamond with Chemically Defined Pentacene Molecules In conventional NV nanodiamonds, the sensing element is a crystal defect consisting of a nitrogen atom adjacent to a vacant carbon site in the diamond lattice. The new MoQN platform uses a different approach. Its quantum sensing element is pentacene, an organic molecule with well-defined electronic spin properties. The researchers incorporated a small amount of pentacene into para-terphenyl nanocrystals and coated the particles with Pluronic F-127, a biocompatible surfactant that improves their dispersibility in water. They fabricated two nominal particle sizes, approximately 200 nm and 500 nm, designated MoQN200 and MoQN500. These values refer to the dimensions of the sensor particles. They should not be confused with the spatial resolution achieved when mapping intracellular temperature. When pentacene absorbs light, it can enter an excited triplet state. This state contains electron-spin sublevels with different energies. Applying microwaves at an appropriate frequency changes the populations of these sublevels, producing a corresponding change in fluorescence. The researchers measured this response using optically detected magnetic resonance (ODMR). The principle is somewhat similar to tuning a radio receiver to a particular frequency. By identifying the resonance frequency of the electron spins, researchers can obtain information about the local environment surrounding the sensor. One of the first important results was the uniformity of resonance frequencies among individual particles. For approximately 200 nm MoQNs, the standard deviation of ODMR resonance positions was ±0.13 MHz, compared with ±0.45 MHz for similarly sized nanodiamonds containing NV centers. For the approximately 500 nm particles, the corresponding values were ±0.18 MHz for MoQNs and ±2.85 MHz for nanodiamonds. In the 200 nm comparison, the variation in resonance positions was therefore reduced by more than threefold. This greater uniformity matters because absolute temperature measurement requires knowing the relationship between a sensor's resonance frequency and temperature. If different particles have substantially different baseline resonance frequencies, a frequency difference between two intracellular locations may be difficult to interpret. Using molecular spin centers with more uniform resonance properties reduces this source of uncertainty. However, the study does not show that MoQNs outperform nanodiamonds in every aspect of quantum sensing. The average continuous-wave ODMR contrast was approximately 2% for MoQNs, whereas the 200 nm and 500 nm nanodiamonds used for comparison exhibited contrasts of approximately 6% and 3%, respectively. The central advantage of the molecular platform is therefore not universally stronger ODMR contrast, but the combination of resonance-frequency uniformity and the ability to chemically modify the molecular spin environment through isotope substitution. ■ Coherent Spin Control Remained Possible Inside Living Cells A molecular quantum sensor that functions in a laboratory sample will not necessarily perform equally well inside a living cell. The intracellular environment contains water, ions, proteins, and numerous other molecules that can affect spin behavior. Introducing nanoparticles or exposing cells to light and microwaves may also cause cellular stress or damage. The researchers therefore first examined whether MoQNs could be introduced into living cells without substantially disrupting cell viability and function under the tested conditions. They delivered MoQNs into Hepa1-6 cells, a mouse liver cancer cell line, and assessed plasma membrane integrity, apoptosis-associated caspase activity, metabolic reducing activity, and cell-cycle progression through DNA synthesis. The assays did not detect substantial impairment under the experimental conditions. Comparable results were obtained in HEK-293H and HepG2 cells. The researchers also reported preserved cell viability during observations extending to approximately 72 hours. These findings support the biological compatibility of MoQNs under the conditions examined, although they do not establish long-term safety across all cell types or exposure conditions. The researchers then used confocal microscopy to locate individual MoQN particles inside living cells and measure their spin properties. Continuous-wave ODMR measurements produced a contrast of approximately 1.5% within cells. They also demonstrated coherent manipulation of the electron spins by applying microwave pulses and observing Rabi oscillations, with a contrast of approximately 3%. The intracellular spin-lattice relaxation time, T1, was approximately 75 μs, while the spin coherence time, T2, measured through spin-echo experiments, was on the order of 1 μs. These results establish that MoQNs do more than function as ordinary fluorescent labels. Even inside living cells, their electron-spin states can be read optically and manipulated coherently using microwave pulses. An important conceptual distinction is necessary, however. Demonstrating coherent spin control inside a living cell does not mean that the cell's biological functions themselves rely on quantum coherence. In this experiment, the quantum state belongs to a sensor introduced by the researchers. Quantum coherence is the operating principle of the measurement device, not a demonstrated mechanism used by the cell to perform its physiological functions. ■ Deuterating Pentacene Improved the Precision of the Molecular Thermometer For a quantum sensor to measure absolute temperature, researchers must first establish how its resonance frequency changes with temperature. In MoQNs, temperature-dependent changes in the surrounding para-terphenyl crystal affect the zero-field splitting parameters of the pentacene triplet state. These changes shift the ODMR resonance frequency, providing a basis for temperature measurement. However, hyperfine interactions between electron spins and nearby hydrogen nuclear spins can create additional spectral components, making the resonance signal more complicated to analyze. The researchers addressed this problem through molecular isotope engineering. They replaced hydrogen atoms in pentacene with deuterium, a heavier isotope of hydrogen, creating deuterated molecular quantum nanosensors, or dMoQNs. Deuteration modifies the interactions between electron spins and surrounding nuclear spins, suppressing the hyperfine-related spectral complexity that can interfere with precise resonance-frequency measurements. Combined with the relatively uniform resonance frequencies already achieved in MoQNs, this chemical modification allowed the researchers to convert the resonance positions of individual particles into absolute temperature readings more reliably. In temperature calibration experiments outside cells, the ODMR frequency shifted by 102.4 ± 7.87 kHz/K. Inside living cells, the measured temperature coefficient was 102.3 ± 3.81 kHz/K. The close agreement between these two values supports the use of dMoQNs for temperature measurements in biological environments. The researchers also tested whether changes in the surrounding chemical environment could si

Zenodo (CERN European Organization for Nuclear Research)
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon