Validation of a neonatal computational anthropomorphic phantom using Monte Carlo simulation
This study presents the validation of a neonatal computational anthropomorphic phantom developed by the Federal University of Sergipe (UFS) using Monte Carlo simulations performed with the MCNPX 2.7.0 code. The model was compared with the ICRP 143 reference phantom in terms of absorbed and effective dose for 10 irradiation geometries (0°, 45°, 90°, 135°, 180°, 225°, 270°, 315°, ISO and ROT) and photon energies from 50 keV to 10 MeV. The results presented relative differences <5% for anteroposterior irradiation, while small deviations were generally observed for isotropic (ISO) and rotational (ROT) geometries. Larger differences were observed at low energies and in directional geometries, reaching maximum values of ~30%–35%, particularly for posteroanterior irradiation, while minimum differences were <1% at higher energies. The same was observed for effective dose results. Overall, the differences decreased with increasing photon energy, confirming the reliability of the UFS phantom for neonatal dosimetry and radiation protection applications.
Authors
- Ana Paula Perini (ORCID: https://orcid.org/0000-0003-3398-3165)
- Beatriz Hellen Aparecida Pereira (ORCID: https://orcid.org/0000-0002-9779-9706)
- Albérico B. de Carvalho
- William Souza de Santos (ORCID: https://orcid.org/0000-0002-3828-5000)
- Lucio P Neves
- Franklin S S Leite
- Arthur S B Z Alves
Institutions
- Universidade Federal de Sergipe (BR)
- Universidade Federal de Uberlândia (BR)
Publication Details
- Journal
- Radiation Protection Dosimetry
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1093/rpd/ncag132
- Primary Topic
- Radiation Dose and Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00