Validation of a neonatal computational anthropomorphic phantom using Monte Carlo simulation

This study presents the validation of a neonatal computational anthropomorphic phantom developed by the Federal University of Sergipe (UFS) using Monte Carlo simulations performed with the MCNPX 2.7.0 code. The model was compared with the ICRP 143 reference phantom in terms of absorbed and effective dose for 10 irradiation geometries (0°, 45°, 90°, 135°, 180°, 225°, 270°, 315°, ISO and ROT) and photon energies from 50 keV to 10 MeV. The results presented relative differences <5% for anteroposterior irradiation, while small deviations were generally observed for isotropic (ISO) and rotational (ROT) geometries. Larger differences were observed at low energies and in directional geometries, reaching maximum values of ~30%–35%, particularly for posteroanterior irradiation, while minimum differences were <1% at higher energies. The same was observed for effective dose results. Overall, the differences decreased with increasing photon energy, confirming the reliability of the UFS phantom for neonatal dosimetry and radiation protection applications.

Authors

Institutions

Publication Details

Journal
Radiation Protection Dosimetry
Published
2026-11-26
DOI
https://doi.org/10.1093/rpd/ncag132
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Validation of a neonatal computational anthropomorphic phantom using Monte Carlo simulation

Ana Paula Perini, Beatriz Hellen Aparecida Pereira, Albérico B. de Carvalho, William Souza de Santos et al.
Radiation Protection Dosimetry
Radiation Dose and Imaging
article

Validation of a neonatal computational anthropomorphic phantom using Monte Carlo simulation

Ana Paula Perini, Beatriz Hellen Aparecida Pereira, Albérico B. de Carvalho, William Souza de Santos, Lucio P Neves, Franklin S S Leite, Arthur S B Z Alves
article en

Abstract

This study presents the validation of a neonatal computational anthropomorphic phantom developed by the Federal University of Sergipe (UFS) using Monte Carlo simulations performed with the MCNPX 2.7.0 code. The model was compared with the ICRP 143 reference phantom in terms of absorbed and effective dose for 10 irradiation geometries (0°, 45°, 90°, 135°, 180°, 225°, 270°, 315°, ISO and ROT) and photon energies from 50 keV to 10 MeV. The results presented relative differences <5% for anteroposterior irradiation, while small deviations were generally observed for isotropic (ISO) and rotational (ROT) geometries. Larger differences were observed at low energies and in directional geometries, reaching maximum values of ~30%–35%, particularly for posteroanterior irradiation, while minimum differences were <1% at higher energies. The same was observed for effective dose results. Overall, the differences decreased with increasing photon energy, confirming the reliability of the UFS phantom for neonatal dosimetry and radiation protection applications.

Radiation Protection Dosimetry
Universidade Federal de Sergipe (BR), Universidade Federal de Uberlândia (BR)
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon