A Standards-First Adaptive Quality-Gated Fusion Method for Multi-Source Physiological Signals in Wearable Devices

Wearable multi-source physiological monitoring is vulnerable to time-varying motion artifacts, poor contact, and optical interference. Fixed-weight fusion may therefore become less accurate than a reliable single-channel estimate. This paper proposes a standards-first adaptive quality-gated fusion method in which heterogeneous ECG, PPG, temperature, and acceleration observations are first mapped to a common task-estimation layer. Each sensor registers a quality specification bound to a contract hash and configuration epoch. A fast motion pre-check and sliding-window signal quality indices (SQIs) generate quality states that are attached to data frames and drive hard gating, reliability weighting, and four-state switching. Mechanism-level simulations using MIT-BIH/NSTDB data and rule-based stress scenarios show that heart-rate MAE decreases from 31.61 to 17.47 bpm in the running stress case (44.7% improvement). Hardware motion pre-check latency is 1.8 ms, whereas software SQI processing requires 6.7-7.8 ms after a window is ready; the update interval is governed by the 2.5-s window step. Timeline reconstruction reduces the clock-drift contribution to PTT timing error from 29.7 to 0.1 ms at ±200 ppm drift. A 10,000-frame software consistency test detects all injected contract, epoch, sequence, and CRC violations without false alarms.

Authors

Institutions

Publication Details

Journal
Advances in computer and materials science research.
Published
2026-11-26
DOI
https://doi.org/10.70114/acmsr.2026.9.1.p39
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

A Standards-First Adaptive Quality-Gated Fusion Method for Multi-Source Physiological Signals in Wearable Devices

Shun Liu, Shuowei Cao, Lin Wang, Geng Liu et al.
Advances in computer and materials science research.
Non-Invasive Vital Sign Monitoring
article

A Standards-First Adaptive Quality-Gated Fusion Method for Multi-Source Physiological Signals in Wearable Devices

Shun Liu, Shuowei Cao, Lin Wang, Geng Liu, Yaqi Gen
article en

Abstract

Wearable multi-source physiological monitoring is vulnerable to time-varying motion artifacts, poor contact, and optical interference. Fixed-weight fusion may therefore become less accurate than a reliable single-channel estimate. This paper proposes a standards-first adaptive quality-gated fusion method in which heterogeneous ECG, PPG, temperature, and acceleration observations are first mapped to a common task-estimation layer. Each sensor registers a quality specification bound to a contract hash and configuration epoch. A fast motion pre-check and sliding-window signal quality indices (SQIs) generate quality states that are attached to data frames and drive hard gating, reliability weighting, and four-state switching. Mechanism-level simulations using MIT-BIH/NSTDB data and rule-based stress scenarios show that heart-rate MAE decreases from 31.61 to 17.47 bpm in the running stress case (44.7% improvement). Hardware motion pre-check latency is 1.8 ms, whereas software SQI processing requires 6.7-7.8 ms after a window is ready; the update interval is governed by the 2.5-s window step. Timeline reconstruction reduces the clock-drift contribution to PTT timing error from 29.7 to 0.1 ms at ±200 ppm drift. A 10,000-frame software consistency test detects all injected contract, epoch, sequence, and CRC violations without false alarms.

Advances in computer and materials science research.Vol. 9(1)
Northwestern Polytechnical University (CN)
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.