Not all DNase 1 are created equal

DNase I is a ubiquitous reagent, used to remove contaminating DNA from RNA preparations and other samples, and preparations from different suppliers are widely treated as interchangeable. Suppliers describe their products as improved --- faster, more complete, more stable --- but what better means is rarely defined in terms a user can reproduce: activity units are tied to each supplier's own assay, recommended protocols specify a single amount and a single time, and stability in storage, through freeze--thaw cycles and at working temperature, is seldom quantified. Here we adapt a low-cost fluorophore--quencher reporter of the kind used for Cas12 trans-cleavage diagnostics as a kinetic assay for DNase I, and compare preparations from three suppliers, each used at 1 U/μ L, on plates that carry blanks, replicates and a standard of fully digested reporter. At large amounts (16--32 U) ThermoFisher and Zymo preparations were indistinguishable early in the reaction. At sub-saturating amounts (≤4 U) the product formed per labelled unit differed up to ≈3.6-fold at 1 U (Zymo over ThermoFisher) and by considerably more at 0.25--0.5 U, where ThermoFisher signal was close to background. The ranking depended on dose, on time, and on whether rate or yield was the metric: from about 3 h onward ThermoFisher formed the least product at 1--4 U yet had the shortest fitted time constants, Synthego and Zymo were similar at ≤1 U, and Synthego, slower to start, yielded more than Zymo after about 2--3 h at 4 U. On a single plate, two Zymo DNase I aliquots from different laboratories differed up to 19-fold at equal nominal volume. We argue that DNase I performance should be reported as calibrated dose--response and time-course data under stated conditions, with storage stability quantified, and that laboratories should verify the enzyme they actually hold. The reporter costs about $0.10 per reaction, is in principle readable on a simple LED fluorometer, and can be modified to probe dsDNA, RNA and nucleic-acid--binding proteins.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-11-26
DOI
https://doi.org/10.64898/2026.11.23.768681
Primary Topic
CRISPR and Genetic Engineering
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Not all DNase 1 are created equal

Janice B. Fung, Ravi Sachidanandam, Daniel Kopulos, Madison Spears et al.
bioRxiv (Cold Spring Harbor Laboratory)
CRISPR and Genetic Engineering
preprint

Not all DNase 1 are created equal

Janice B. Fung, Ravi Sachidanandam, Daniel Kopulos, Madison Spears, Deepali Lehri
preprint en

Abstract

DNase I is a ubiquitous reagent, used to remove contaminating DNA from RNA preparations and other samples, and preparations from different suppliers are widely treated as interchangeable. Suppliers describe their products as improved --- faster, more complete, more stable --- but what better means is rarely defined in terms a user can reproduce: activity units are tied to each supplier's own assay, recommended protocols specify a single amount and a single time, and stability in storage, through freeze--thaw cycles and at working temperature, is seldom quantified. Here we adapt a low-cost fluorophore--quencher reporter of the kind used for Cas12 trans-cleavage diagnostics as a kinetic assay for DNase I, and compare preparations from three suppliers, each used at 1 U/μ L, on plates that carry blanks, replicates and a standard of fully digested reporter. At large amounts (16--32 U) ThermoFisher and Zymo preparations were indistinguishable early in the reaction. At sub-saturating amounts (≤4 U) the product formed per labelled unit differed up to ≈3.6-fold at 1 U (Zymo over ThermoFisher) and by considerably more at 0.25--0.5 U, where ThermoFisher signal was close to background. The ranking depended on dose, on time, and on whether rate or yield was the metric: from about 3 h onward ThermoFisher formed the least product at 1--4 U yet had the shortest fitted time constants, Synthego and Zymo were similar at ≤1 U, and Synthego, slower to start, yielded more than Zymo after about 2--3 h at 4 U. On a single plate, two Zymo DNase I aliquots from different laboratories differed up to 19-fold at equal nominal volume. We argue that DNase I performance should be reported as calibrated dose--response and time-course data under stated conditions, with storage stability quantified, and that laboratories should verify the enzyme they actually hold. The reporter costs about $0.10 per reaction, is in principle readable on a simple LED fluorometer, and can be modified to probe dsDNA, RNA and nucleic-acid--binding proteins.

bioRxiv (Cold Spring Harbor Laboratory)
New York Medical College (US)
CRISPR and Genetic Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon