Monitoring the Magnetic Field in Dipoles with Permanent Magnets of the SKIF Storage Device
One of the features of the magnetic structure of the SKIF storage device is the use of dipoles with permanent magnets, which has a number of advantages. However, the lack of confidence in the stable magnetization of permanent magnets during operation initiated the development of tools for measuring long-term field drifts to have them compensated. By now, prototypes of two subsystems for long-term field monitoring in dipoles, duplicating each other, have been developed and tested. One uses the NMR method, the other employs measurements with Hall sensors. Working versions of subsystems are currently under development. The reasons for creating duplicate systems details of measurement methods are discussed, and designs of the NMR sensor and Hall sensor are presented. The structures of subsystems, main parameters, and results of magnetic measurements are also described.
Authors
- A. M. Batrakov
- G. V. Karpov
- V. V. Kobets
- I.N. Okunev (ORCID: https://orcid.org/0000-0002-4000-3965)
- S. Sinyatkin
- D. P. Chernovsky
- A. Yu. Pakhomov
Institutions
- Russian Academy of Sciences (RU)
- Novosibirsk State University (RU)
- Siberian Branch of the Russian Academy of Sciences (RU)
Publication Details
- Journal
- Physics of Particles and Nuclei Letters
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1134/s1547477126700998
- Primary Topic
- Particle accelerators and beam dynamics
- Type
- article
- Field-Weighted Citation Impact
- 0.00