The influence of surface reflectivity on the accuracy of surface topography mapping with non-contact measurement techniques
Surface reflectivity can substantially affect the reliability of non-contact surface topography measurements because optical techniques reconstruct an electromagnetic rather than a mechanical surface. This study investigates the effect of reflectance on surface topography parameters measured on polished AISI 316 L steel specimens, both uncoated and coated with DLC, TiN, TiCN, TiAlN, ZrN, and CrN coatings used in biomedical applications. Surface reflectance and color were determined by spectrophotometry, while topography was measured using coherence scanning interferometry (CSI), imaging confocal microscopy (ICM), focus variation microscopy (FV), and confocal fusion (CF). Contact profilometry was used as the reference method of measurement. The comparison included the Sa, Sq, Sz, Ssk, and Sku parameters and a normalized coefficient of variation, (V_s). The analyzed specimens exhibited reflectance values from (Y = 1.05%) to (Y = 11.12%) in the specular-component-excluded mode. At reflectance values of approximately 10–11%, V s ranged from 0% to 80% for Sa and from 0% to 40% for Sq. For low-reflectance surfaces ((Y = 1.05–2.40%)), unsuitable combinations of optical technique and illumination produced V s values exceeding 200% and, in extreme cases, 1000%. For Sa and Sq measurements within this low-reflectance range, CSI with green or white illumination provided the closest agreement with the contact-reference results. Higher-order parameters were considerably less stable: Sku values obtained from optical measurements exceeded 300–400 in some configurations because of their high sensitivity to noise and isolated surface-reconstruction artifacts. The results demonstrate that reflectance, illumination wavelength, and the selected surface parameter must be considered jointly when choosing an optical topography measurement procedure. This is particularly important for smooth biomedical components with low-reflectance coatings.
Authors
- Michał Wieczorowski (ORCID: https://orcid.org/0000-0001-7526-8368)
- Monika Madej (ORCID: https://orcid.org/0000-0001-9892-9181)
- Michał Jakubowicz (ORCID: https://orcid.org/0000-0002-6350-0411)
- Magdalena Niemczewska-Wójcik (ORCID: https://orcid.org/0000-0001-9902-478X)
- Grzegorz Krolczyk (ORCID: https://orcid.org/0000-0002-2967-1719)
- Piotr Niesłony (ORCID: https://orcid.org/0000-0001-8776-8458)
Institutions
- Opole University of Technology (PL)
- Kielce University of Technology (PL)
- Cracow University of Technology (PL)
- Polish Naval Academy (PL)
- Poznań University of Technology (PL)
Publication Details
- Journal
- Scientific Reports
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1038/s41598-026-82176-4
- Primary Topic
- Surface Roughness and Optical Measurements
- Type
- article
- Field-Weighted Citation Impact
- 0.00