Polymeric particle-contact effects on apparent phenylalanine recovery by an enzymatic colorimetric assay

Contact with polymeric particulate materials may change the response of enzymatic colorimetric assays through analyte partitioning, filtration losses, or matrix-dependent effects. This study examined apparent phenylalanine (Phe) signal recovery following contact with particles derived from polyethylene terephthalate (PET) bottles, polypropylene (PP) plates, and cellulose-based paper cups. Materials were characterized by FTIR and Raman spectroscopy and contacted with buffered Phe solutions (20, 60, or 100 µm) at particle loadings of 1, 3, or 10 mg/mL for nominal durations of 2, 6, 24, 48, and 96 h. After 0.45-µm filtration, filtrates were analyzed by an enzyme/developer-based assay at 450 nm. Apparent signal recovery was normalized to concentration- and time-matched Phe-only controls. Across 45 conditions per material, mean apparent recoveries were 70.5% for PET (range 40.3–91.2%), 41.9% for PP (7.1–85.9%), and 7.3% for cellulose-based particles (0.2–24.6%). PET showed a loading-associated decline in recovery, whereas PP exhibited more variable, nonmonotonic profiles. The pronounced suppression observed for cup-derived material showed that effects were not confined to synthetic plastic particles. Because measurements were made on processed filtrates, reduced colorimetric response cannot be assigned uniquely to Phe adsorption. Potential contributions include particle-associated analyte removal, soluble matrix constituents, and filter-passing particulate matter. These findings identify substantial material-dependent changes in the apparent Phe analytical response under controlled buffer conditions and support the use of matrix-matched and orthogonal measurements to distinguish analyte depletion from assay interference.

Authors

Institutions

Publication Details

Journal
Journal of Chemical Metrology
Published
2026-11-26
DOI
https://doi.org/10.25135/jcm.2610-4051
Primary Topic
Analytical chemistry methods development
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Polymeric particle-contact effects on apparent phenylalanine recovery by an enzymatic colorimetric assay

Aslı Baysal, Hasan Saygın, Mustafa Özyürek, Gülsüm Çiçek
Journal of Chemical Metrology
Analytical chemistry methods development
article

Polymeric particle-contact effects on apparent phenylalanine recovery by an enzymatic colorimetric assay

Aslı Baysal, Hasan Saygın, Mustafa Özyürek, Gülsüm Çiçek
article en

Abstract

Contact with polymeric particulate materials may change the response of enzymatic colorimetric assays through analyte partitioning, filtration losses, or matrix-dependent effects. This study examined apparent phenylalanine (Phe) signal recovery following contact with particles derived from polyethylene terephthalate (PET) bottles, polypropylene (PP) plates, and cellulose-based paper cups. Materials were characterized by FTIR and Raman spectroscopy and contacted with buffered Phe solutions (20, 60, or 100 µm) at particle loadings of 1, 3, or 10 mg/mL for nominal durations of 2, 6, 24, 48, and 96 h. After 0.45-µm filtration, filtrates were analyzed by an enzyme/developer-based assay at 450 nm. Apparent signal recovery was normalized to concentration- and time-matched Phe-only controls. Across 45 conditions per material, mean apparent recoveries were 70.5% for PET (range 40.3–91.2%), 41.9% for PP (7.1–85.9%), and 7.3% for cellulose-based particles (0.2–24.6%). PET showed a loading-associated decline in recovery, whereas PP exhibited more variable, nonmonotonic profiles. The pronounced suppression observed for cup-derived material showed that effects were not confined to synthetic plastic particles. Because measurements were made on processed filtrates, reduced colorimetric response cannot be assigned uniquely to Phe adsorption. Potential contributions include particle-associated analyte removal, soluble matrix constituents, and filter-passing particulate matter. These findings identify substantial material-dependent changes in the apparent Phe analytical response under controlled buffer conditions and support the use of matrix-matched and orthogonal measurements to distinguish analyte depletion from assay interference.

Journal of Chemical MetrologyVol. 20(2)
Istanbul Aydın University (TR), Istanbul University-Cerrahpaşa (TR), Istanbul Technical University (TR)
Analytical chemistry methods development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon