Removing λ-Inflation from the Consecutive-Prime Hardy–Littlewood Density: A Pre-Registered Test at 10¹²

Removing λ-Inflation from the Consecutive-Prime Hardy–Littlewood Density: A Pre-Registered Test at 1012 Entry 026 of this series confirmed, in a pre-registered test, that lag-1 correlations E[χ(pn)χ(pn+1)] of consecutive primes for χ−3, χ−4 and (·/5) have the Hardy–Littlewood (HL) size once the singular series is evaluated exactly at the primes up to 19. Its model, an absorption ladder, also raises the base density λ at every rung and so has no limit at fixed height; at 1012 the data sat +1.7 to +2.4 standard errors above it. This paper replaces the ladder at the unabsorbed primes by a fixed-λ control-variate hybrid: exact sieving at the primes up to 19, plus a transfer-matrix cumulant expansion of the HL singular series at base modulus Q0 = 60 (deterministic through k = 5 points, Monte Carlo at k = 6, with an explicit truncation allowance). Pre-registered test (Entry 028). Predictions for the hybrid and the ladder were frozen and pushed to GitHub before any data existed. The band [1.05·1012, 2.05·1012) was sampled in 2,000 stratified runs seeded from a drand beacon round published after the freeze (round 6671641), giving 2.5·1010 consecutive pairs. Six decisive tests: T-lad (data above the ladder) and T-hyb (data within tolerance of the hybrid) for each of the three characters. Result: 6 of 6 decisive tests came out as predicted. T-lad: the data lie above the ladder by z = +15.91, +11.52 and +7.00 (χ−3, χ−4, (·/5)). T-hyb: agreement with the hybrid within −0.52, +1.15 and +0.74 standard errors (without the tolerance); ĉ/chyb = 1.00004, 0.99991, 0.99994. The arm-E offsets of Entry 026 are therefore the ladder’s λ-inflation, not a departure from Hardy–Littlewood. Transparency. The hybrid was developed after Entry 026’s arm-E data had been seen; this is disclosed in the paper, and it is the reason the test uses a fresh band. The tolerance for the k ≥ 7 remainder is a stated judgement, not a proof, and the test covers one height decade and lag 1 only. AI assistance (Gemini, Claude) is described in the paper. Contents of this record: the paper (PDF and LaTeX source), the two figures, and the scripts that generate every number and figure from the frozen Entry 028 records, plus an audit script and its log (252 checks, all passed; frozen manifest verifies 70/70). Related records: the Entry 028 data and code archive (frozen entry, manifest, run log, beacon verification, data, code), concept doi:10.5281/zenodo.24566229 (version 1, doi:10.5281/zenodo.24566230); Entry 026 paper, doi:10.5281/zenodo.24472492; Entry 026 archive, concept doi:10.5281/zenodo.24173334 (version 3, doi:10.5281/zenodo.24204049).

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24566534
Primary Topic
Analytic Number Theory Research
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Removing λ-Inflation from the Consecutive-Prime Hardy–Littlewood Density: A Pre-Registered Test at 10¹²

Matthew Gifford
Zenodo (CERN European Organization for Nuclear Research)
Analytic Number Theory Research
preprint

Removing λ-Inflation from the Consecutive-Prime Hardy–Littlewood Density: A Pre-Registered Test at 10¹²

Matthew Gifford
preprint en

Abstract

Removing λ-Inflation from the Consecutive-Prime Hardy–Littlewood Density: A Pre-Registered Test at 1012 Entry 026 of this series confirmed, in a pre-registered test, that lag-1 correlations E[χ(pn)χ(pn+1)] of consecutive primes for χ−3, χ−4 and (·/5) have the Hardy–Littlewood (HL) size once the singular series is evaluated exactly at the primes up to 19. Its model, an absorption ladder, also raises the base density λ at every rung and so has no limit at fixed height; at 1012 the data sat +1.7 to +2.4 standard errors above it. This paper replaces the ladder at the unabsorbed primes by a fixed-λ control-variate hybrid: exact sieving at the primes up to 19, plus a transfer-matrix cumulant expansion of the HL singular series at base modulus Q0 = 60 (deterministic through k = 5 points, Monte Carlo at k = 6, with an explicit truncation allowance). Pre-registered test (Entry 028). Predictions for the hybrid and the ladder were frozen and pushed to GitHub before any data existed. The band [1.05·1012, 2.05·1012) was sampled in 2,000 stratified runs seeded from a drand beacon round published after the freeze (round 6671641), giving 2.5·1010 consecutive pairs. Six decisive tests: T-lad (data above the ladder) and T-hyb (data within tolerance of the hybrid) for each of the three characters. Result: 6 of 6 decisive tests came out as predicted. T-lad: the data lie above the ladder by z = +15.91, +11.52 and +7.00 (χ−3, χ−4, (·/5)). T-hyb: agreement with the hybrid within −0.52, +1.15 and +0.74 standard errors (without the tolerance); ĉ/chyb = 1.00004, 0.99991, 0.99994. The arm-E offsets of Entry 026 are therefore the ladder’s λ-inflation, not a departure from Hardy–Littlewood. Transparency. The hybrid was developed after Entry 026’s arm-E data had been seen; this is disclosed in the paper, and it is the reason the test uses a fresh band. The tolerance for the k ≥ 7 remainder is a stated judgement, not a proof, and the test covers one height decade and lag 1 only. AI assistance (Gemini, Claude) is described in the paper. Contents of this record: the paper (PDF and LaTeX source), the two figures, and the scripts that generate every number and figure from the frozen Entry 028 records, plus an audit script and its log (252 checks, all passed; frozen manifest verifies 70/70). Related records: the Entry 028 data and code archive (frozen entry, manifest, run log, beacon verification, data, code), concept doi:10.5281/zenodo.24566229 (version 1, doi:10.5281/zenodo.24566230); Entry 026 paper, doi:10.5281/zenodo.24472492; Entry 026 archive, concept doi:10.5281/zenodo.24173334 (version 3, doi:10.5281/zenodo.24204049).

Zenodo (CERN European Organization for Nuclear Research)
Analytic Number Theory Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon