Nuclear-timed switches: passive activation and deactivation after 10^3–10^6 years of dormancy using decay-heat maxima and minima

Systems that must lie dormant for millennia and then act cannot rely on clocks or counters. The decay heat of actinide sources can replace them: in a companion paper we showed that pure start nuclides pass through delayed heat maxima, and some through a minimum before, at times fixed by nuclear constants. Here we turn these curves into switches without moving solid parts and without computers. A threshold on the electric power of 150 kg U-234 at 6 % conversion wakes a system at 41,300 years and shuts it down at 470,000 years. A thermal switch, a body heated by the source whose filling melts, does the same with temperature alone (T ∝ P1/4): with lithium (453.65 K) it melts at 41,300 years and refreezes at 470,000 years; a calibration error of 1 K shifts the wake-up by about 663 years, and the same body filled with indium or tin switches at 27,800 and 105,000 years. On the falling flank before a minimum the heat drops steeply, so a reverse switch is more precise: for Pu-238 a threshold at twice the minimum is crossed downwards at 1,010 years and upwards again at 19,900 years, giving two events from one threshold. A differential switch compares two identical bodies heated by two sources whose curves cross; multiplicative errors common to both, such as emissivity or insulation, cancel, and a 1 % mass error shifts the switching time by only 0.2–0.8 %. We quantify the limits: half-life uncertainties (0.01–1.1 % of the switching time), dissolved impurities and supercooling of the switch metal, which makes freezing switches unreliable unless a solid seed is kept. As an application we describe a small fission reactor whose liquid-lithium reactivity switch is physically locked until the rising U-234 heat melts the lithium. Companion papers: Delayed decay-heat maxima in actinide decay chains (the physics of the heat curves) and EAGLE EYE (a probe that uses these switches), both on Zenodo. The code archive contains all Python scripts; nuclear data are downloaded from the IAEA LiveChart of Nuclides.

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24562455
Primary Topic
Advanced Energy Technologies and Civil Engineering Innovations
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Nuclear-timed switches: passive activation and deactivation after 10^3–10^6 years of dormancy using decay-heat maxima and minima

Dominik Sebastian Adler
Zenodo (CERN European Organization for Nuclear Research)
Advanced Energy Technologies and Civil Engineering Innovations
preprint

Nuclear-timed switches: passive activation and deactivation after 10^3–10^6 years of dormancy using decay-heat maxima and minima

Dominik Sebastian Adler
preprint en

Abstract

Systems that must lie dormant for millennia and then act cannot rely on clocks or counters. The decay heat of actinide sources can replace them: in a companion paper we showed that pure start nuclides pass through delayed heat maxima, and some through a minimum before, at times fixed by nuclear constants. Here we turn these curves into switches without moving solid parts and without computers. A threshold on the electric power of 150 kg U-234 at 6 % conversion wakes a system at 41,300 years and shuts it down at 470,000 years. A thermal switch, a body heated by the source whose filling melts, does the same with temperature alone (T ∝ P1/4): with lithium (453.65 K) it melts at 41,300 years and refreezes at 470,000 years; a calibration error of 1 K shifts the wake-up by about 663 years, and the same body filled with indium or tin switches at 27,800 and 105,000 years. On the falling flank before a minimum the heat drops steeply, so a reverse switch is more precise: for Pu-238 a threshold at twice the minimum is crossed downwards at 1,010 years and upwards again at 19,900 years, giving two events from one threshold. A differential switch compares two identical bodies heated by two sources whose curves cross; multiplicative errors common to both, such as emissivity or insulation, cancel, and a 1 % mass error shifts the switching time by only 0.2–0.8 %. We quantify the limits: half-life uncertainties (0.01–1.1 % of the switching time), dissolved impurities and supercooling of the switch metal, which makes freezing switches unreliable unless a solid seed is kept. As an application we describe a small fission reactor whose liquid-lithium reactivity switch is physically locked until the rising U-234 heat melts the lithium. Companion papers: Delayed decay-heat maxima in actinide decay chains (the physics of the heat curves) and EAGLE EYE (a probe that uses these switches), both on Zenodo. The code archive contains all Python scripts; nuclear data are downloaded from the IAEA LiveChart of Nuclides.

Zenodo (CERN European Organization for Nuclear Research)
Advanced Energy Technologies and Civil Engineering Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Nuclear-timed switches: passive activation and deactivation after 10^3–10^6 years of dormancy using decay-heat maxima and minima — Dominik Sebastian Adler · Zenodo (CERN European Organization for Nuclear Research) (2026) | TGRS Research Map | TGRS