Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

Background Pathology-labeled optical narrow-band imaging (NBI) is difficult to assemble for laryngeal lesion classification. Translating existing white-light imaging (WLI) into virtual NBI (Vir-NBI) may improve learning from limited real-NBI data, but its value beyond that of the original images is uncertain. Objective This study aimed to determine whether Vir-NBI pretraining improves real-NBI classification or label efficiency compared with pretraining on the same pathology-labeled WLI. Methods This multicenter study compared ResNet-50 classifiers pretrained on pathology-labeled WLI or paired Vir-NBI images generated by a frozen, region-of-interest–guided CycleGAN (cycle-consistent generative adversarial network). The primary outcome was the image-level area under the receiver operating characteristic curve (AUC) difference (Vir-NBI minus WLI). Label efficiency was evaluated in these external cohorts with 10 to 100 labeled real-NBI patients and 25 paired training runs per sample size. Color-matched augmentation and paired test-modality analyses examined the influence of color change and test modality. Prospective temporal validation and a 12-clinician assessment evaluated patient-level performance and perceived image quality. Results The CHCAMS (National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) cohort comprised 1245 patients with 8476 paired WLI–Vir-NBI images. External validation included 182 patients from CHSZCAMS (Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) and 129 from People’s Hospital of Wenshan Prefecture (WSPH). External image-level AUCs were 0.806 with WLI and 0.787 with Vir-NBI (difference −0.019, 95% CI −0.047 to 0.008; P =.17). With 10 labeled real-NBI patients, external patient-level AUCs were 0.843 and 0.773, respectively (difference −0.070, 95% CI −0.116 to −0.029; Holm-adjusted P =.006). The normalized area-under-the-learning-curve difference across 10 to 100 patients favored WLI (−0.049, 95% CI −0.090 to −0.011; Holm-adjusted P =.01). Color-matched WLI augmentation yielded higher external image-level AUC than with Vir-NBI (0.774 vs 0.739; difference 0.036, unadjusted 95% CI 0.004-0.070). In the 58-case examination-linked cohort, relative Vir-NBI performance improved on translated test images (primary-model interaction 0.235, unadjusted 95% CI 0.080-0.390); fixed-duration and all-view sensitivity analyses had case-level CIs that included 0. In the CHCAMS prospective validation cohort (138 patients), patient-level AUCs were 0.846 (95% CI 0.775‐0.910) and 0.844 (95% CI 0.777‐0.905), respectively. WLI identified 90.9% (60/66) of high-risk patients, compared with 81.8% (54/66) with Vir-NBI, reflecting 6 discordant patients (exact McNemar P =.03; Holm-adjusted P =.06). Among 100 image pairs from the CHCAMS source cohort, clinicians rated plausibility as 4 to 5 in 86.9% (1043/1200) of ratings; intraclass correlation coefficients for the mean ratings of 12 clinicians ranged from 0.398 (95% CI 0.265-0.497) to 0.583 (95% CI 0.471-0.659). Conclusions Vir-NBI pretraining did not demonstrate incremental value over WLI for real-NBI classification. External learning curves favored WLI with small real-NBI training sets. Test-domain dependence suggests that compatibility with real-NBI may contribute to performance differences.

Authors

Publication Details

Journal
JMIR Medical Informatics
Published
2026-11-26
DOI
https://doi.org/10.2196/109811
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

M. Wang, Xiao‐Guang Ni, Ji‐Qing Zhu, Yu-Da Zhao et al.
JMIR Medical Informatics
AI in cancer detection
article

Clinical Plausibility and Pretraining Utility of Virtual Narrow-Band Imaging for Laryngeal Lesion Classification: Multicenter Model Development and Validation Study

M. Wang, Xiao‐Guang Ni, Ji‐Qing Zhu, Yu-Da Zhao, Jie-Lin Huang, Li-Zhou Dou, Yu-Meng Liu, Xue Zhang, Li-Juan Li
article en

Abstract

Background Pathology-labeled optical narrow-band imaging (NBI) is difficult to assemble for laryngeal lesion classification. Translating existing white-light imaging (WLI) into virtual NBI (Vir-NBI) may improve learning from limited real-NBI data, but its value beyond that of the original images is uncertain. Objective This study aimed to determine whether Vir-NBI pretraining improves real-NBI classification or label efficiency compared with pretraining on the same pathology-labeled WLI. Methods This multicenter study compared ResNet-50 classifiers pretrained on pathology-labeled WLI or paired Vir-NBI images generated by a frozen, region-of-interest–guided CycleGAN (cycle-consistent generative adversarial network). The primary outcome was the image-level area under the receiver operating characteristic curve (AUC) difference (Vir-NBI minus WLI). Label efficiency was evaluated in these external cohorts with 10 to 100 labeled real-NBI patients and 25 paired training runs per sample size. Color-matched augmentation and paired test-modality analyses examined the influence of color change and test modality. Prospective temporal validation and a 12-clinician assessment evaluated patient-level performance and perceived image quality. Results The CHCAMS (National Cancer Center/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) cohort comprised 1245 patients with 8476 paired WLI–Vir-NBI images. External validation included 182 patients from CHSZCAMS (Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College) and 129 from People’s Hospital of Wenshan Prefecture (WSPH). External image-level AUCs were 0.806 with WLI and 0.787 with Vir-NBI (difference −0.019, 95% CI −0.047 to 0.008; P =.17). With 10 labeled real-NBI patients, external patient-level AUCs were 0.843 and 0.773, respectively (difference −0.070, 95% CI −0.116 to −0.029; Holm-adjusted P =.006). The normalized area-under-the-learning-curve difference across 10 to 100 patients favored WLI (−0.049, 95% CI −0.090 to −0.011; Holm-adjusted P =.01). Color-matched WLI augmentation yielded higher external image-level AUC than with Vir-NBI (0.774 vs 0.739; difference 0.036, unadjusted 95% CI 0.004-0.070). In the 58-case examination-linked cohort, relative Vir-NBI performance improved on translated test images (primary-model interaction 0.235, unadjusted 95% CI 0.080-0.390); fixed-duration and all-view sensitivity analyses had case-level CIs that included 0. In the CHCAMS prospective validation cohort (138 patients), patient-level AUCs were 0.846 (95% CI 0.775‐0.910) and 0.844 (95% CI 0.777‐0.905), respectively. WLI identified 90.9% (60/66) of high-risk patients, compared with 81.8% (54/66) with Vir-NBI, reflecting 6 discordant patients (exact McNemar P =.03; Holm-adjusted P =.06). Among 100 image pairs from the CHCAMS source cohort, clinicians rated plausibility as 4 to 5 in 86.9% (1043/1200) of ratings; intraclass correlation coefficients for the mean ratings of 12 clinicians ranged from 0.398 (95% CI 0.265-0.497) to 0.583 (95% CI 0.471-0.659). Conclusions Vir-NBI pretraining did not demonstrate incremental value over WLI for real-NBI classification. External learning curves favored WLI with small real-NBI training sets. Test-domain dependence suggests that compatibility with real-NBI may contribute to performance differences.

JMIR Medical InformaticsVol. 14
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon