Harmonization, Synthetic Data

Quantitative measurements used in nuclear medicine imaging are becoming increasingly decisive in disease detection, staging, and treatment response evaluation. This review addresses harmonization and synthetic data use, which increase the reliability and generalizability of numerical measurements and artificial intelligence (AI) models. The first section addresses harmonization. Differences in technical characteristics and imaging protocols between centers, or between devices within the same center, make numerical data difficult to compare. This causes non-biological artificial variations in multicenter studies. Harmonization strategies fall into two groups: image-based corrections, and statistical correction of numerical data. In image corrections, center effects are reduced using internationally accepted standards and phantoms. In statistical corrections, the ComBat method and its improved versions are commonly preferred. In recent years, AI methods have also been incorporated into harmonization. Studies show harmonization increases AI models’ success in disease classification and survival prediction, with more consistent results. The second section focuses on synthetic data. Access to quality, large datasets required by AI models is restricted by patient privacy, rare disease scarcity, and radiation exposure. Synthetic data technologies offer an innovative solution: data created by imitating the distribution of real data using mathematical models and algorithms. Deep learning architectures such as generative adversarial networks, variational autoencoders, vision transformer, and denoising diffusion models enable quality synthetic medical images. These images are used to expand AI training sets, improve diagnostic quality of low-dose or short-duration scans, and perform cross-modality image conversion for attenuation correction in hybrid systems. In conclusion, harmonization methods and synthetic data generation approaches, as mutually reinforcing strategic building blocks, carry potential to increase AI model reliability in nuclear medicine. Addressing both approaches in an integrated manner will lay groundwork for standardizing next-generation diagnostic and treatment monitoring protocols in imaging. However, using these methods in clinical practice requires support from comprehensive studies.

Authors

Institutions

Publication Details

Journal
Nuclear Medicine Seminars
Published
2026-11-26
DOI
https://doi.org/10.4274/nts.galenos.2026.46338
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Harmonization, Synthetic Data

Erdem Balcı, Seda Gülbahar Ateş
Nuclear Medicine Seminars
Medical Imaging Techniques and Applications
article

Harmonization, Synthetic Data

Erdem Balcı, Seda Gülbahar Ateş
article en

Abstract

Quantitative measurements used in nuclear medicine imaging are becoming increasingly decisive in disease detection, staging, and treatment response evaluation. This review addresses harmonization and synthetic data use, which increase the reliability and generalizability of numerical measurements and artificial intelligence (AI) models. The first section addresses harmonization. Differences in technical characteristics and imaging protocols between centers, or between devices within the same center, make numerical data difficult to compare. This causes non-biological artificial variations in multicenter studies. Harmonization strategies fall into two groups: image-based corrections, and statistical correction of numerical data. In image corrections, center effects are reduced using internationally accepted standards and phantoms. In statistical corrections, the ComBat method and its improved versions are commonly preferred. In recent years, AI methods have also been incorporated into harmonization. Studies show harmonization increases AI models’ success in disease classification and survival prediction, with more consistent results. The second section focuses on synthetic data. Access to quality, large datasets required by AI models is restricted by patient privacy, rare disease scarcity, and radiation exposure. Synthetic data technologies offer an innovative solution: data created by imitating the distribution of real data using mathematical models and algorithms. Deep learning architectures such as generative adversarial networks, variational autoencoders, vision transformer, and denoising diffusion models enable quality synthetic medical images. These images are used to expand AI training sets, improve diagnostic quality of low-dose or short-duration scans, and perform cross-modality image conversion for attenuation correction in hybrid systems. In conclusion, harmonization methods and synthetic data generation approaches, as mutually reinforcing strategic building blocks, carry potential to increase AI model reliability in nuclear medicine. Addressing both approaches in an integrated manner will lay groundwork for standardizing next-generation diagnostic and treatment monitoring protocols in imaging. However, using these methods in clinical practice requires support from comprehensive studies.

Nuclear Medicine Seminars
Gazi University (TR)
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon