Effects of a High-Airflow Fan-Attached Garment on Thermoregulatory and Physiological Responses During Physical Activity in Hot Environments: A Randomized Crossover Trial

Objectives: Although fan-attached garments are widely used, conventional airflow rates have shown limited efficacy in suppressing core body temperature elevation during physical activity. We aimed to investigate the effects of a high-airflow fan-attached garment on core body temperature and physiological strain during physical activity in hot environments under different humidity levels. Methods: Seven healthy adult men completed four randomized crossover trials involving two environmental conditions - wet bulb globe temperatures of 25 degrees C (36 degrees C, 20% relative humidity) and 31 degrees C (36 degrees C, 60% relative humidity) - and two garment conditions: control and fan-attached garment (80 L/s airflow). Each trial consisted of a 10-min thermoneutral rest, 10-min hot rest, and 60-min continuous cycle ergometer exercise (60 W). We evaluated rectal and skin temperatures, heart rate, microclimate environment, body mass change, and subjective sensations. Results: At a wet bulb globe temperature of 31 degrees C, the fan-attached garment significantly suppressed the increase in rectal temperature compared with the control garment at 60 min of exercise (difference: 0.50 degrees C, p < 0.001), with rectal temperature remaining unchanged from baseline (+0.11 degrees C, p = 0.077). Exercise heart rate (difference: 31.5 beats/min, p < 0.001) and body mass loss (difference: 0.5 kg, p = 0.001) were also significantly reduced with the fan-attached garment. Microclimate humidity was significantly lower with the fan-attached garment throughout exercise in both environments (p < 0.001). Conclusions: The high-airflow (80 L/s) fan-attached garment effectively prevented an increase in core body temperature and mitigated cardiovascular and thermoregulatory strain during moderate physical activity, even in hot and humid environments.

Authors

Publication Details

Journal
medRxiv
Published
2026-11-25
DOI
https://doi.org/10.64898/2026.11.23.26368461
Primary Topic
Thermoregulation and physiological responses
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Effects of a High-Airflow Fan-Attached Garment on Thermoregulatory and Physiological Responses During Physical Activity in Hot Environments: A Randomized Crossover Trial

Hironaga Ito, Fuminori Takayama, Megumi Wanifuchi, Yuki Urushizawa et al.
medRxiv
Thermoregulation and physiological responses
preprint

Effects of a High-Airflow Fan-Attached Garment on Thermoregulatory and Physiological Responses During Physical Activity in Hot Environments: A Randomized Crossover Trial

Hironaga Ito, Fuminori Takayama, Megumi Wanifuchi, Yuki Urushizawa, Kazuma Hayashi, Yoshihito Tomioka
preprint en

Abstract

Objectives: Although fan-attached garments are widely used, conventional airflow rates have shown limited efficacy in suppressing core body temperature elevation during physical activity. We aimed to investigate the effects of a high-airflow fan-attached garment on core body temperature and physiological strain during physical activity in hot environments under different humidity levels. Methods: Seven healthy adult men completed four randomized crossover trials involving two environmental conditions - wet bulb globe temperatures of 25 degrees C (36 degrees C, 20% relative humidity) and 31 degrees C (36 degrees C, 60% relative humidity) - and two garment conditions: control and fan-attached garment (80 L/s airflow). Each trial consisted of a 10-min thermoneutral rest, 10-min hot rest, and 60-min continuous cycle ergometer exercise (60 W). We evaluated rectal and skin temperatures, heart rate, microclimate environment, body mass change, and subjective sensations. Results: At a wet bulb globe temperature of 31 degrees C, the fan-attached garment significantly suppressed the increase in rectal temperature compared with the control garment at 60 min of exercise (difference: 0.50 degrees C, p < 0.001), with rectal temperature remaining unchanged from baseline (+0.11 degrees C, p = 0.077). Exercise heart rate (difference: 31.5 beats/min, p < 0.001) and body mass loss (difference: 0.5 kg, p = 0.001) were also significantly reduced with the fan-attached garment. Microclimate humidity was significantly lower with the fan-attached garment throughout exercise in both environments (p < 0.001). Conclusions: The high-airflow (80 L/s) fan-attached garment effectively prevented an increase in core body temperature and mitigated cardiovascular and thermoregulatory strain during moderate physical activity, even in hot and humid environments.

medRxiv
Thermoregulation and physiological responses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon