Beyond heart rate: Beat-to-beat ECG morphology for trust-related state classification

Trust is a fundamental construct in human–automation interaction (HAI), yet electrocardiogram (ECG)-based trust sensing remains limited by inconsistent findings and narrow feature representations. This study compares heart rate variability (HRV), which primarily characterises inter-beat timing, with beat-to-beat (B2B) ECG features that retain additional waveform-level timing and amplitude information for trust-related state classification. ECG signals were recorded from 13 participants during a controlled word- and scenario-cued trust/distrust elicitation paradigm. Across HRV representations, within-participant discrimination was higher than cross-participant discrimination for some feature sets, indicating representation-dependent limitations in cross-participant transfer in the present sample. Under the primary cross-participant evaluation, B2B significantly outperformed the combined time- and frequency-domain HRV representation (HRV-Full; AUC = 0.649 versus 0.453; exact paired p = 0.0059 ). However, its advantage over the strongest HRV-only representation, frequency-domain HRV (HRV-FD; AUC = 0.561), was not statistically significant ( p = 0.1086 ). Importantly, although B2B showed nominal evidence of above-chance cross-participant discrimination (raw p = 0.0155 ), this result did not survive false discovery rate (FDR) correction across the four unique predictive representations ( q = 0.0620 ). Nevertheless, the comparative advantage of B2B over HRV-Full persisted under zero-shot evaluation (AUC = 0.643 versus 0.493; exact paired p = 0.0144 ), indicating that this finding did not depend on participant-specific calibration. To further interpret the B2B representation, fold-wise SHapley Additive exPlanations (SHAP) analysis identified repeatedly selected model-attributed features related to PR-interval and waveform-amplitude variability. Taken together, B2B features provided greater cross-participant discrimination than HRV-Full in this exploratory sample, while substantial inter-participant variability, lack of FDR-corrected above-chance B2B performance, and modest absolute generalisation highlight the need for larger-scale validation in interactive HAI settings.

Authors

Institutions

Publication Details

Journal
Biomedical Signal Processing and Control
Published
2026-11-26
DOI
https://doi.org/10.1016/j.bspc.2026.111910
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Beyond heart rate: Beat-to-beat ECG morphology for trust-related state classification

Asim Bhatti, Julakha Jahan Jui, Imali Thanuja Hettiarachchi
Biomedical Signal Processing and Control
Heart Rate Variability and Autonomic Control
article

Beyond heart rate: Beat-to-beat ECG morphology for trust-related state classification

Asim Bhatti, Julakha Jahan Jui, Imali Thanuja Hettiarachchi
article en

Abstract

Trust is a fundamental construct in human–automation interaction (HAI), yet electrocardiogram (ECG)-based trust sensing remains limited by inconsistent findings and narrow feature representations. This study compares heart rate variability (HRV), which primarily characterises inter-beat timing, with beat-to-beat (B2B) ECG features that retain additional waveform-level timing and amplitude information for trust-related state classification. ECG signals were recorded from 13 participants during a controlled word- and scenario-cued trust/distrust elicitation paradigm. Across HRV representations, within-participant discrimination was higher than cross-participant discrimination for some feature sets, indicating representation-dependent limitations in cross-participant transfer in the present sample. Under the primary cross-participant evaluation, B2B significantly outperformed the combined time- and frequency-domain HRV representation (HRV-Full; AUC = 0.649 versus 0.453; exact paired p = 0.0059 ). However, its advantage over the strongest HRV-only representation, frequency-domain HRV (HRV-FD; AUC = 0.561), was not statistically significant ( p = 0.1086 ). Importantly, although B2B showed nominal evidence of above-chance cross-participant discrimination (raw p = 0.0155 ), this result did not survive false discovery rate (FDR) correction across the four unique predictive representations ( q = 0.0620 ). Nevertheless, the comparative advantage of B2B over HRV-Full persisted under zero-shot evaluation (AUC = 0.643 versus 0.493; exact paired p = 0.0144 ), indicating that this finding did not depend on participant-specific calibration. To further interpret the B2B representation, fold-wise SHapley Additive exPlanations (SHAP) analysis identified repeatedly selected model-attributed features related to PR-interval and waveform-amplitude variability. Taken together, B2B features provided greater cross-participant discrimination than HRV-Full in this exploratory sample, while substantial inter-participant variability, lack of FDR-corrected above-chance B2B performance, and modest absolute generalisation highlight the need for larger-scale validation in interactive HAI settings.

Biomedical Signal Processing and ControlVol. 132
Deakin University (AU)
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon