Indoor exercise and particulate matter: PM2.5 resuspension during the use of different gym equipment: A pilot study

This study aimed to assess the elevation of PM2.5 concentrations during physical exercise by healthy adults using different gym equipment in a physiotherapy exercise room. Eight optical particle counters measured PM concentrations at head height in the physiotherapy exercise room, which was equipped with two stationary bicycles, an elliptic trainer, and a rowing machine. Measurements were performed before the exercises to obtain background particle concentrations and during medium intensity training. Four healthy volunteers (either men or women) exercised on two bicycles, one rowing machine and one elliptic trainer for 30 min, and the measurements were repeated on eight different days. The background PM2.5 concentrations varied from 2.28 ± 0.27 µg m −3 to 4.14 ± 0.25 µg m −3 before the training. The concentrations significantly increased when men exercised, by 3.42 ± 1.30 µg m −3 using a rowing machine and 3.50 ± 1.35 µg m −3 using a stationary bicycle, compared to the background at exercise intensities ranging from 53 to 96 W. For women, a smaller increase was observed (PM2.5 contribution increased between 1.17 ± 0.13 µg m −3 and 1.78 ± 0.69 µg m −3 at exercise intensities from 35 to 60 W). We investigated, for the first time, PM2.5 exposure levels among individuals performing medium intensity exercise in an indoor gym, broken down by gender and type of gym equipment. Using various gym equipment during a workout increases PM2.5 concentration; however, this does not justify avoiding such activities, as the positive effects of exercise far outweigh the negative effects of the higher dust levels observed.

Authors

Institutions

Publication Details

Journal
Physiology International
Published
2026-11-26
DOI
https://doi.org/10.1556/2060.2026.00958
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Indoor exercise and particulate matter: PM2.5 resuspension during the use of different gym equipment: A pilot study

Katica Kup, Tamás Erdélyi, János Tamás Varga, Szilvia Kugler et al.
Physiology International
Indoor Air Quality and Microbial Exposure
article

Indoor exercise and particulate matter: PM2.5 resuspension during the use of different gym equipment: A pilot study

Katica Kup, Tamás Erdélyi, János Tamás Varga, Szilvia Kugler, Szabina B. Török, Attila Nagy, Veronika Müller
article en

Abstract

This study aimed to assess the elevation of PM2.5 concentrations during physical exercise by healthy adults using different gym equipment in a physiotherapy exercise room. Eight optical particle counters measured PM concentrations at head height in the physiotherapy exercise room, which was equipped with two stationary bicycles, an elliptic trainer, and a rowing machine. Measurements were performed before the exercises to obtain background particle concentrations and during medium intensity training. Four healthy volunteers (either men or women) exercised on two bicycles, one rowing machine and one elliptic trainer for 30 min, and the measurements were repeated on eight different days. The background PM2.5 concentrations varied from 2.28 ± 0.27 µg m −3 to 4.14 ± 0.25 µg m −3 before the training. The concentrations significantly increased when men exercised, by 3.42 ± 1.30 µg m −3 using a rowing machine and 3.50 ± 1.35 µg m −3 using a stationary bicycle, compared to the background at exercise intensities ranging from 53 to 96 W. For women, a smaller increase was observed (PM2.5 contribution increased between 1.17 ± 0.13 µg m −3 and 1.78 ± 0.69 µg m −3 at exercise intensities from 35 to 60 W). We investigated, for the first time, PM2.5 exposure levels among individuals performing medium intensity exercise in an indoor gym, broken down by gender and type of gym equipment. Using various gym equipment during a workout increases PM2.5 concentration; however, this does not justify avoiding such activities, as the positive effects of exercise far outweigh the negative effects of the higher dust levels observed.

Physiology International
Semmelweis University (HU), HUN-REN Wigner Research Centre for Physics (HU), HUN-REN Centre for Energy Research (HU)
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon