Repeated Laser Exposure Enhances Electrochemical Response in Ag/Laser-Induced Graphene Electrodes with a Hierarchical Assessment of Fabrication Reproducibility

Laser-induced graphene (LIG) provides a scalable, maskless route to porous carbon electrodes, but variability among independently fabricated devices and batches limits reliable manufacturing. Here, a controlled Ag/LIG workflow was used to examine how a one- to three-pass laser sequence affects material structure, electrochemical response, and fabrication reproducibility. SEM indicated pass-dependent network restructuring within the sampled fields, Raman spectroscopy showed greater but spatially nonuniform graphitic ordering, and X-ray photoelectron spectroscopy indicated greater sp2 character and modest surface deoxygenation with repeated laser exposure. Three-pass electrodes produced an approximately 2.3-fold higher square-wave voltammetric response than one-pass electrodes in ferri/ferrocyanide solution. Cyclic voltammetry, impedance spectroscopy, and direct resistance measurements on representative electrodes showed that the largest resistance decrease occurred between one and two passes, whereas conditional apparent electroactive area continued to increase, with the larger increment occurring between two and three passes; charge-transfer resistance remained comparatively small and showed no systematic dependence on pass number. Reproducibility of the selected three-pass process was evaluated using 18 devices from three fabrication batches and 162 voltammograms: scan-to-scan relative SD was below 0.5%, while device-within-batch and batch relative SDs were 2.6–3.6% and 2.0–4.4%, respectively. These results link controlled multipass processing to staged improvements in electrical transport and electrochemical accessibility and provide a hierarchical framework for quantifying the fabrication reproducibility of porous carbon electrodes.

Authors

Institutions

Publication Details

Journal
ACS Omega
Published
2026-11-26
DOI
https://doi.org/10.1021/acsomega.6c09276
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Repeated Laser Exposure Enhances Electrochemical Response in Ag/Laser-Induced Graphene Electrodes with a Hierarchical Assessment of Fabrication Reproducibility

Rourke Sylvain, Smitha Rao, Grace Dykstra, Yixin Liu et al.
ACS Omega
Electrochemical sensors and biosensors
article

Repeated Laser Exposure Enhances Electrochemical Response in Ag/Laser-Induced Graphene Electrodes with a Hierarchical Assessment of Fabrication Reproducibility

Rourke Sylvain, Smitha Rao, Grace Dykstra, Yixin Liu, Asky Fungura, Hugh Hanlon, Matthew Barsch
article en

Abstract

Laser-induced graphene (LIG) provides a scalable, maskless route to porous carbon electrodes, but variability among independently fabricated devices and batches limits reliable manufacturing. Here, a controlled Ag/LIG workflow was used to examine how a one- to three-pass laser sequence affects material structure, electrochemical response, and fabrication reproducibility. SEM indicated pass-dependent network restructuring within the sampled fields, Raman spectroscopy showed greater but spatially nonuniform graphitic ordering, and X-ray photoelectron spectroscopy indicated greater sp2 character and modest surface deoxygenation with repeated laser exposure. Three-pass electrodes produced an approximately 2.3-fold higher square-wave voltammetric response than one-pass electrodes in ferri/ferrocyanide solution. Cyclic voltammetry, impedance spectroscopy, and direct resistance measurements on representative electrodes showed that the largest resistance decrease occurred between one and two passes, whereas conditional apparent electroactive area continued to increase, with the larger increment occurring between two and three passes; charge-transfer resistance remained comparatively small and showed no systematic dependence on pass number. Reproducibility of the selected three-pass process was evaluated using 18 devices from three fabrication batches and 162 voltammograms: scan-to-scan relative SD was below 0.5%, while device-within-batch and batch relative SDs were 2.6–3.6% and 2.0–4.4%, respectively. These results link controlled multipass processing to staged improvements in electrical transport and electrochemical accessibility and provide a hierarchical framework for quantifying the fabrication reproducibility of porous carbon electrodes.

ACS Omega
Michigan Technological University (US)
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon