A generalizable fit-for-purpose workflow for multiplex targeted mass-spectrometry of protein-based blood biomarkers: validation and clinical application to neurodegenerative diseases in a 400-patient cohort
Objectives Accurate quantification of endogenous plasma proteins remains a major challenge for clinical translation of proteomic biomarkers, particularly in neurodegenerative diseases where low-abundance targets coexist with highly abundant proteins in a complex matrix. Fit-for-purpose validation frameworks compatible with ICH M10 guidelines offer an adapted strategy for multiplex targeted mass-spectrometry assays. We developed and validated a streamlined LC-MRM workflow for plasma biomarker quantification and evaluated its analytical applicability and biological coherence in a deeply phenotyped Alzheimer’s disease (AD) cohort. Methods Twenty-four proteotypic peptides representing 20 protein biomarkers were selected based on prior evidence and mass spectrometry (MS) detectability. Cleavable, winged stable isotope-labeled (SIL) peptides were used as surrogate analytes and internal standards to account for digestion and downstream analytical variability in the absence of a true blank plasma matrix. Analytical validation assessed linearity, accuracy expressed as percentage of nominal concentration, bias, precision, carry-over, matrix effects, digestion efficiency, stability, and inter-operator reproducibility. The panel was applied to 400+ samples from the ALZAN cohort (NCT05427448), classified by cerebrospinal fluid amyloid/tau/neurodegeneration (AT[N]) status. Results Twenty-one of 24 peptides met acceptance criteria; 17 were endogenously measurable in plasma. Linearity (R 2 ≥0.98), precision (CV≤20 %), and accuracy (80–120 % of nominal concentration) were consistently achieved. Matrix effects were substantial but were compensated by the cleavable SIL strategy. PARK7 and Clusterin were significantly decreased in AD vs. controls (p<0.01), and Transthyretin differed between non-AD neurodegenerative conditions and controls. AT-stratified analyses identified differences in PARK7, Clusterin, ApoE, and Osteopontin across groups. Conclusions This LC-MRM workflow combines analytical rigor with streamlined processing for large-scale multiplex protein biomarker quantification in plasma, with demonstrated translational potential for broader clinical research application.
Authors
- Sylvain Lehmann (ORCID: https://orcid.org/0000-0001-6117-562X)
- Christophe Hirtz (ORCID: https://orcid.org/0000-0002-7313-0629)
- Jérôme Vialaret (ORCID: https://orcid.org/0000-0002-3730-2366)
- Karim Bennys (ORCID: https://orcid.org/0000-0003-1363-0143)
- Ann‐Christin Niehoff
- Florine Leipp (ORCID: https://orcid.org/0009-0006-4105-3434)
- Marie Duchiron (ORCID: https://orcid.org/0009-0008-5122-5070)
Institutions
- Inserm (FR)
- Université de Montpellier (FR)
- Centre Hospitalier Universitaire de Montpellier (FR)
- Institute for Regenerative Medicine & Biotherapy (FR)
- Institute for Neurosciences of Montpellier (FR)
Publication Details
- Journal
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Published
- 2026-11-27
- DOI
- https://doi.org/10.1515/cclm-2026-1070
- Primary Topic
- Advanced Proteomics Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00