Benchmark Validation of the Direct Mathematical Method for HPGe Detector Efficiency Calibration Against Experimental Data, EFFTRAN, and Geant4-Based RayXpert Simulations

Accurate full-energy peak efficiency (FEPE) calibration of high-purity germanium (HPGe) detectors is essential for quantitative gamma-ray spectrometry and numerous applications in nuclear science and technology. Although Monte Carlo radiation-transport simulations and efficiency-transfer techniques are widely employed for detector efficiency determination, their implementation often requires detailed detector characterization and considerable computational effort. In the present study, the Direct Mathematical Method (DMM) was evaluated as an analytical alternative through comparison with experimental measurements, EFFTRAN calculations, and Geant4-based RayXpert simulations reported for a 78.5% relative-efficiency n-type coaxial HPGe detector. The detector-response parameter required by the DMM, namely the effective photopeak attenuation coefficient, was derived from the experimental efficiency data and subsequently used to predict FEPE values over a wide gamma-ray energy range. Calculated efficiencies were compared with experimental, EFFTRAN, and RayXpert results using relative-deviation analysis together with statistical performance indicators, including the coefficient of determination (R²), root-mean-square error (RMSE), and mean absolute percentage error (MAPE). The DMM accurately reproduced the experimental efficiency curve across the investigated energy range, yielding absolute relative deviations ranging from 0.09% to 0.92%, with a mean absolute deviation of only 0.38%. These results demonstrate substantially better agreement with the experimental data than both RayXpert and EFFTRAN. The findings indicate that the DMM provides a reliable and computationally efficient framework for HPGe detector efficiency calibration and detector-response characterization, demonstrating that the DMM constitutes an accurate and computationally efficient alternative to both Monte Carlo-based and efficiency-transfer methodologies for HPGe detector efficiency calibration.

Authors

Institutions

Publication Details

Journal
Research Square
Published
2026-11-26
DOI
https://doi.org/10.21203/rs.3.rs-11799622/v1
Primary Topic
Radiation Detection and Scintillator Technologies
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Benchmark Validation of the Direct Mathematical Method for HPGe Detector Efficiency Calibration Against Experimental Data, EFFTRAN, and Geant4-Based RayXpert Simulations

Mahmoud Ibrahim Abbas
Research Square
Radiation Detection and Scintillator Technologies
preprint

Benchmark Validation of the Direct Mathematical Method for HPGe Detector Efficiency Calibration Against Experimental Data, EFFTRAN, and Geant4-Based RayXpert Simulations

Mahmoud Ibrahim Abbas
preprint en

Abstract

Accurate full-energy peak efficiency (FEPE) calibration of high-purity germanium (HPGe) detectors is essential for quantitative gamma-ray spectrometry and numerous applications in nuclear science and technology. Although Monte Carlo radiation-transport simulations and efficiency-transfer techniques are widely employed for detector efficiency determination, their implementation often requires detailed detector characterization and considerable computational effort. In the present study, the Direct Mathematical Method (DMM) was evaluated as an analytical alternative through comparison with experimental measurements, EFFTRAN calculations, and Geant4-based RayXpert simulations reported for a 78.5% relative-efficiency n-type coaxial HPGe detector. The detector-response parameter required by the DMM, namely the effective photopeak attenuation coefficient, was derived from the experimental efficiency data and subsequently used to predict FEPE values over a wide gamma-ray energy range. Calculated efficiencies were compared with experimental, EFFTRAN, and RayXpert results using relative-deviation analysis together with statistical performance indicators, including the coefficient of determination (R²), root-mean-square error (RMSE), and mean absolute percentage error (MAPE). The DMM accurately reproduced the experimental efficiency curve across the investigated energy range, yielding absolute relative deviations ranging from 0.09% to 0.92%, with a mean absolute deviation of only 0.38%. These results demonstrate substantially better agreement with the experimental data than both RayXpert and EFFTRAN. The findings indicate that the DMM provides a reliable and computationally efficient framework for HPGe detector efficiency calibration and detector-response characterization, demonstrating that the DMM constitutes an accurate and computationally efficient alternative to both Monte Carlo-based and efficiency-transfer methodologies for HPGe detector efficiency calibration.

Research Square
Alexandria University (EG)
Radiation Detection and Scintillator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Benchmark Validation of the Direct Mathematical Method for HPGe Detector Efficiency Calibration Against Experimental Data, EFFTRAN, and Geant4-Based RayXpert Simulations — Mahmoud Ibrahim Abbas · Research Square (2026) | TGRS Research Map | TGRS