Dimensional Accuracy of 3D-Printed Surgical Guides in Relation to Design Modifications and Fabrication Workflow: An Exploratory Laboratory Pilot Study

Background/Objectives: Manufacturing and post-processing may alter the dimensions of printed surgical guides. This exploratory study examined dimensional fidelity across four design/workflow combinations derived from one maxillary implant-planning case. Methods: Four SLA-printed guides represented a 2 × 2 arrangement combining distal reinforcement, present or absent, with support removal before or after polymerization, with one specimen per combination. Fifteen inter-sleeve distances, one reference-point distance, and six sleeve diameters were evaluated separately across printing, polymerization, and steam sterilization. Physical dimensions were compared with the corresponding digital design dimensions. Analyses were descriptive. Results: Dimensional discrepancies varied between specimens and manufacturing stages. Guide 2, incorporating distal reinforcement with support removal before polymerization, had the lowest observed mean absolute inter-sleeve error after sterilization. Changes between polymerization and post-sterilization did not consistently increase absolute discrepancy from the design. Conclusions: These specimen-specific observations support further investigation of guide design and fabrication workflow. With one guide per condition, manufacturing effects cannot be separated from specimen variability, and implant-placement accuracy cannot be inferred.

Authors

Institutions

Publication Details

Journal
Dentistry Journal
Published
2026-11-26
DOI
https://doi.org/10.3390/dj14120777
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Dimensional Accuracy of 3D-Printed Surgical Guides in Relation to Design Modifications and Fabrication Workflow: An Exploratory Laboratory Pilot Study

Zsuzsanna Bardocz-Veres, Mihai Vlad Golu, Melinda Székely, Szidonia Krisztina Veress et al.
Dentistry Journal
Dental Implant Techniques and Outcomes
article

Dimensional Accuracy of 3D-Printed Surgical Guides in Relation to Design Modifications and Fabrication Workflow: An Exploratory Laboratory Pilot Study

Zsuzsanna Bardocz-Veres, Mihai Vlad Golu, Melinda Székely, Szidonia Krisztina Veress, Cristina Molna-Varlam, Szabolcs Bencze
article en

Abstract

Background/Objectives: Manufacturing and post-processing may alter the dimensions of printed surgical guides. This exploratory study examined dimensional fidelity across four design/workflow combinations derived from one maxillary implant-planning case. Methods: Four SLA-printed guides represented a 2 × 2 arrangement combining distal reinforcement, present or absent, with support removal before or after polymerization, with one specimen per combination. Fifteen inter-sleeve distances, one reference-point distance, and six sleeve diameters were evaluated separately across printing, polymerization, and steam sterilization. Physical dimensions were compared with the corresponding digital design dimensions. Analyses were descriptive. Results: Dimensional discrepancies varied between specimens and manufacturing stages. Guide 2, incorporating distal reinforcement with support removal before polymerization, had the lowest observed mean absolute inter-sleeve error after sterilization. Changes between polymerization and post-sterilization did not consistently increase absolute discrepancy from the design. Conclusions: These specimen-specific observations support further investigation of guide design and fabrication workflow. With one guide per condition, manufacturing effects cannot be separated from specimen variability, and implant-placement accuracy cannot be inferred.

Dentistry JournalVol. 14(12)
Universitatea de Medicină, Farmacie, Științe și Tehnologie „George Emil Palade” din Târgu Mureș (RO)
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Dimensional Accuracy of 3D-Printed Surgical Guides in Relation to Design Modifications and Fabrication Workflow: An Exploratory Laboratory Pilot Study — Zsuzsanna Bardocz-Veres, Mihai Vlad Golu, et al. · Dentistry Journal (2026) | TGRS Research Map | TGRS