Claimed versus Independently Verifiable Performance in Brain-Computer Interface Announcements: The Case of Neuralink, 2024-2026
Company announcements supply much of what the public and regulators know about implanted brain-computer interfaces, yet few external sources exist against which to read them. I audit 22 quantitative claims that Neuralink published on its website between January 2024 and November 2026. Each claim has an archived primary source and is classified as direct, with caveat or not comparable, according to whether an external comparator with the same definition and population exists. Four claims (18.2%) are direct, thirteen (59.1%) carry a caveat and five (22.7%) are not comparable. The direct claims are study launches and a financing announcement; none concerns performance, safety or usage. No Scopus or Web of Science record with company authorship reports the bit rates announced in 2025 and 2026, and none of seven company-sponsored registered studies has posted results. The audit is a dated snapshot and does not assess whether the technology works.
Authors
- Alfredo Merlet (ORCID: https://orcid.org/0009-0007-8558-164X)
Institutions
- Universidad del Alba (CL)
- Instituto Superior de Artes y Ciencias de la Comunicación (CL)
- Universidad de Sevilla (ES)
Publication Details
- Published
- 2026-11-26
- DOI
- https://doi.org/10.33774/coe-2026-qkd1k
- Primary Topic
- EEG and Brain-Computer Interfaces
- Type
- preprint