ADNET adaptive dual stream network with hierarchical attention fusion for early stage Alzheimer’s disease detection from brain MRI

Alzheimer’s Disease (AD) is a progressive neurodegenerative disorder accounting for 60–80% of dementia cases worldwide, yet no curative treatment exists and early-stage detection remains a persistent clinical challenge. Brain Magnetic Resonance Imaging (MRI) offers a non-invasive means of capturing structural neurodegeneration, making automated MRI-based classification a high-priority research area. This study presents ADNET (Adaptive Dual-stream Network), a hybrid deep learning framework for multi-class AD staging from 2D brain MRI images. ADNET integrates a parallel dual-stream encoder combining EfficientNet-B3 for local convolutional feature extraction with a Swin Transformer for global self-attention, augmented by a Channel-Spatial Progressive Attention (CSPA) module with anatomical prior initialization targeting hippocampal and entorhinal cortex regions. A Hierarchical Attention Fusion (HAF) module enables multi-scale progressive feature integration, and an MRI-Specific Augmentation (MSA) pipeline incorporating seven physiologically grounded strategies addresses class imbalance and domain-specific data scarcity. The model was trained and evaluated on the publicly available Kaggle Alzheimer’s MRI Dataset (6,400 images; four classes) using stratified image-level 70/15/15% splits; because this public derivative dataset does not provide subject or session identifiers, subject-level separation could not be independently verified, and this is treated as a limitation of the study rather than a resolved methodological guarantee. ADNET achieved an overall classification accuracy of 99.41% (95% CI 99.02–99.79%), macro sensitivity of 99.18%, macro specificity of 99.72%, macro F1-score of 99.29%, and macro AUC-ROC of 0.9987 on this benchmark, numerically exceeding the accuracy figures reported in 8 previously published studies on the same or related Kaggle dataset whose citations we were able to independently verify (4 additional studies originally included in this comparison were removed after their source papers could not be located), although these comparisons use results as originally reported rather than baselines reproduced under an identical protocol. A subsequent independent reproduction of the complete described architecture and training recipe (Sect. 5.8) found that training budget mattered substantially: an initial attempt at 20 epochs achieved only 75.44% accuracy, but an extended run (up to 100 epochs, full-depth backbones since the exact backbone configuration could not be confirmed) reached 94.75% overall accuracy and 96.15% macro F1 across a complete, real 5-fold evaluation — still approximately 4.7 and 3.1 percentage points below the headline figures above, respectively, but far closer than the initial attempt suggested. Moderate Demented performance in this reproduction (100%, 64/64) closely matched the original claim. We report this gap prominently and have not fully resolved it; see Sect. 5.8 for the full training-budget progression and disclosed differences in configuration that may explain the remainder. ADNET attained an F1-score of 98.81% for the Very Mild Demented class; performance on the Moderate Demented class (F1 = 100%) is based on only 9–10 test images (depending on fold) and should be interpreted with corresponding caution (95% exact CI approximately 66–100%). Ablation experiments indicate the additive contribution of each architectural component on this dataset. Grad-CAM + + saliency maps showed attention patterns that the authors judged, through an internal, non-blinded qualitative review, to be broadly consistent with expected Alzheimer’s-related atrophy regions; this analysis has not yet been validated by independent clinical experts or registered to an anatomical atlas, and should be regarded as illustrative rather than confirmatory. With only 3.2 million parameters and an inference time of approximately 4 ms per image on the evaluated hardware, ADNET is computationally efficient. These results position ADNET as a promising research prototype for automated Alzheimer’s staging on this benchmark; we make no claim of clinical readiness, and any clinical or population-screening use would require prospective, multi-site, subject-level validation, which we identify as the principal direction for future work.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-26
DOI
https://doi.org/10.1038/s41598-026-76093-9
Primary Topic
Dementia and Cognitive Impairment Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ADNET adaptive dual stream network with hierarchical attention fusion for early stage Alzheimer’s disease detection from brain MRI

Disha H. Parekh, Kalpesh A. Popat, Vivek Gondalia
Scientific Reports
Dementia and Cognitive Impairment Research
article

ADNET adaptive dual stream network with hierarchical attention fusion for early stage Alzheimer’s disease detection from brain MRI

Disha H. Parekh, Kalpesh A. Popat, Vivek Gondalia
article en

Abstract

Alzheimer’s Disease (AD) is a progressive neurodegenerative disorder accounting for 60–80% of dementia cases worldwide, yet no curative treatment exists and early-stage detection remains a persistent clinical challenge. Brain Magnetic Resonance Imaging (MRI) offers a non-invasive means of capturing structural neurodegeneration, making automated MRI-based classification a high-priority research area. This study presents ADNET (Adaptive Dual-stream Network), a hybrid deep learning framework for multi-class AD staging from 2D brain MRI images. ADNET integrates a parallel dual-stream encoder combining EfficientNet-B3 for local convolutional feature extraction with a Swin Transformer for global self-attention, augmented by a Channel-Spatial Progressive Attention (CSPA) module with anatomical prior initialization targeting hippocampal and entorhinal cortex regions. A Hierarchical Attention Fusion (HAF) module enables multi-scale progressive feature integration, and an MRI-Specific Augmentation (MSA) pipeline incorporating seven physiologically grounded strategies addresses class imbalance and domain-specific data scarcity. The model was trained and evaluated on the publicly available Kaggle Alzheimer’s MRI Dataset (6,400 images; four classes) using stratified image-level 70/15/15% splits; because this public derivative dataset does not provide subject or session identifiers, subject-level separation could not be independently verified, and this is treated as a limitation of the study rather than a resolved methodological guarantee. ADNET achieved an overall classification accuracy of 99.41% (95% CI 99.02–99.79%), macro sensitivity of 99.18%, macro specificity of 99.72%, macro F1-score of 99.29%, and macro AUC-ROC of 0.9987 on this benchmark, numerically exceeding the accuracy figures reported in 8 previously published studies on the same or related Kaggle dataset whose citations we were able to independently verify (4 additional studies originally included in this comparison were removed after their source papers could not be located), although these comparisons use results as originally reported rather than baselines reproduced under an identical protocol. A subsequent independent reproduction of the complete described architecture and training recipe (Sect. 5.8) found that training budget mattered substantially: an initial attempt at 20 epochs achieved only 75.44% accuracy, but an extended run (up to 100 epochs, full-depth backbones since the exact backbone configuration could not be confirmed) reached 94.75% overall accuracy and 96.15% macro F1 across a complete, real 5-fold evaluation — still approximately 4.7 and 3.1 percentage points below the headline figures above, respectively, but far closer than the initial attempt suggested. Moderate Demented performance in this reproduction (100%, 64/64) closely matched the original claim. We report this gap prominently and have not fully resolved it; see Sect. 5.8 for the full training-budget progression and disclosed differences in configuration that may explain the remainder. ADNET attained an F1-score of 98.81% for the Very Mild Demented class; performance on the Moderate Demented class (F1 = 100%) is based on only 9–10 test images (depending on fold) and should be interpreted with corresponding caution (95% exact CI approximately 66–100%). Ablation experiments indicate the additive contribution of each architectural component on this dataset. Grad-CAM + + saliency maps showed attention patterns that the authors judged, through an internal, non-blinded qualitative review, to be broadly consistent with expected Alzheimer’s-related atrophy regions; this analysis has not yet been validated by independent clinical experts or registered to an anatomical atlas, and should be regarded as illustrative rather than confirmatory. With only 3.2 million parameters and an inference time of approximately 4 ms per image on the evaluated hardware, ADNET is computationally efficient. These results position ADNET as a promising research prototype for automated Alzheimer’s staging on this benchmark; we make no claim of clinical readiness, and any clinical or population-screening use would require prospective, multi-site, subject-level validation, which we identify as the principal direction for future work.

Scientific Reports
Marwadi University (IN)
Dementia and Cognitive Impairment Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon