MRI Features of Endometrial Hyperplasia With and Without Atypia and Early-Stage Endometrioid Carcinoma

OBJECTIVE: This study aimed to evaluate magnetic resonance imaging (MRI) features of endometrial hyperplasia (EH) and stage IA endometrial endometrioid carcinoma (EEC), and to assess MRI findings for distinguishing EH from EEC and for differentiating endometrial hyperplasia without atypia (EHWA) from endometrial atypical hyperplasia (EAH). METHODS: A total of 304 patients were retrospectively reviewed, including 107 with histopathologically confirmed EH (45 EHWAs and 62 EAHs) and 197 with stage IA EEC, all of whom underwent MRI with diffusion-weighted imaging within 3 months before hysterectomy or biopsy/dilation and curettage. MRI findings were compared across groups. RESULTS: The frequencies of small intralesional cysts on T2-weighted (21% vs. 5%) and fat-suppressed contrast-enhanced T1-weighted (19% vs. 4%) images and intraluminal linear structures on T2-weighted (12% vs. 2%) and fat-suppressed contrast-enhanced T1-weighted (23% vs. 5%) images were higher in EH than in stage IA EEC, respectively (P<0.01). Signal intensity ratios on T2-weighted (2.45±1.14 vs. 1.66±0.65) and fat-suppressed contrast-enhanced T1-weighted (0.97±0.27 vs. 0.81±0.22) images, and apparent diffusion coefficient (ADC) values (1.29±0.34 vs. 0.84±0.18×10-3 mm2/s) were higher in EH than in stage IA EEC, respectively (P<0.01). When comparing EHWA and EAH, the frequencies of small intralesional cysts on T2-weighted images (31% vs. 13%) and ADC values (1.38±0.34 vs. 1.22±0.33×10-3 mm2/s) were higher in EHWA than in EAH, respectively (P<0.05). CONCLUSIONS: Several MRI features, particularly ADC values, T2-weighted signal characteristics, small intralesional cysts, and intraluminal linear structures, may aid differentiation of EH from stage IA EEC. Discrimination between EHWA and EAH was modest and requires validation.

Authors

Institutions

Publication Details

Journal
Journal of Computer Assisted Tomography
Published
2026-11-26
DOI
https://doi.org/10.1097/rct.0000000000001956
Primary Topic
Endometrial and Cervical Cancer Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

MRI Features of Endometrial Hyperplasia With and Without Atypia and Early-Stage Endometrioid Carcinoma

Yoshifumi Noda, Kyoko Kikuno, Hiroki Kato, Yukako Iritani et al.
Journal of Computer Assisted Tomography
Endometrial and Cervical Cancer Treatments
article

MRI Features of Endometrial Hyperplasia With and Without Atypia and Early-Stage Endometrioid Carcinoma

Yoshifumi Noda, Kyoko Kikuno, Hiroki Kato, Yukako Iritani, Hirohiko Imai, Tomohiro Kanayama, Abdelazim Elsayed Elhelaly, Masaya Kawaguchi, Masanori Isobe, Tatsuro Furui, Masayuki Matsuo
article en

Abstract

OBJECTIVE: This study aimed to evaluate magnetic resonance imaging (MRI) features of endometrial hyperplasia (EH) and stage IA endometrial endometrioid carcinoma (EEC), and to assess MRI findings for distinguishing EH from EEC and for differentiating endometrial hyperplasia without atypia (EHWA) from endometrial atypical hyperplasia (EAH). METHODS: A total of 304 patients were retrospectively reviewed, including 107 with histopathologically confirmed EH (45 EHWAs and 62 EAHs) and 197 with stage IA EEC, all of whom underwent MRI with diffusion-weighted imaging within 3 months before hysterectomy or biopsy/dilation and curettage. MRI findings were compared across groups. RESULTS: The frequencies of small intralesional cysts on T2-weighted (21% vs. 5%) and fat-suppressed contrast-enhanced T1-weighted (19% vs. 4%) images and intraluminal linear structures on T2-weighted (12% vs. 2%) and fat-suppressed contrast-enhanced T1-weighted (23% vs. 5%) images were higher in EH than in stage IA EEC, respectively (P<0.01). Signal intensity ratios on T2-weighted (2.45±1.14 vs. 1.66±0.65) and fat-suppressed contrast-enhanced T1-weighted (0.97±0.27 vs. 0.81±0.22) images, and apparent diffusion coefficient (ADC) values (1.29±0.34 vs. 0.84±0.18×10-3 mm2/s) were higher in EH than in stage IA EEC, respectively (P<0.01). When comparing EHWA and EAH, the frequencies of small intralesional cysts on T2-weighted images (31% vs. 13%) and ADC values (1.38±0.34 vs. 1.22±0.33×10-3 mm2/s) were higher in EHWA than in EAH, respectively (P<0.05). CONCLUSIONS: Several MRI features, particularly ADC values, T2-weighted signal characteristics, small intralesional cysts, and intraluminal linear structures, may aid differentiation of EH from stage IA EEC. Discrimination between EHWA and EAH was modest and requires validation.

Journal of Computer Assisted Tomography
Suez Canal University (EG), Gifu University (JP), Innovation Research Center for Quantum Medicine (JP)
Endometrial and Cervical Cancer Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon