Comparison of CT or MRI findings with histopathology in congenital lung malformations

Question addressed by the study What is the accuracy of postnatal thoracic computed tomography (CT) and magnetic resonance imaging (MRI) in the assessment of congenital lung malformations (CLM) compared to the pathological diagnosis? Materials/patients and methods This retrospective multicentre (two tertiary centres) study included patients from 2008 to 2019. Patients prenatally diagnosed with CLM underwent either CT or MRI prior to malformation surgical resection, and one experienced paediatric pathologist per centre evaluated pathology. Accuracy was assessed by comparing imaging-based diagnoses and characteristics with pathology. Interrater agreement was assessed using Cohen's kappa (k). Results Thirty-seven patients with 39 CLMs were included (20 CT, 19 MRI). Both modalities accurately localised lesion, but lesion characterization was inconsistent with pathology. CT demonstrated good size assessment and diagnostic accuracy for congenital pulmonary airway malformations (CPAM) (75%) and sequestration (90–95%) but frequently failed to detect emphysema (40%) and bronchial atresia (50%), whereas MRI showed perfect accuracy for sequestration (100%) but lower accuracy for other diagnoses (47% for CPAM, 58% for emphysema and 58–74% for bronchial atresia). Interrater agreement was high for both modalities (k=0.7–1.0) across most outcomes assessed. Answer to the question Both CT and MRI provide reliable and reproducible assessment of CLM in infants with good performances. CT confirms its strengths for size assessment and CPAM, while MRI achieved good diagnostic performances and represent a valuable radiation-free modality in experienced centre. Pathology remains the gold standard for final diagnosis.

Authors

Institutions

Publication Details

Journal
ERJ Open Research
Published
2026-11-26
DOI
https://doi.org/10.1183/23120541.01251-2026
Primary Topic
Congenital Diaphragmatic Hernia Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Comparison of CT or MRI findings with histopathology in congenital lung malformations

Ueli Moehrlen, Robin Rey, Isabelle Ruchonnet-Métrailler, Christian Johannes Kellenberger et al.
ERJ Open Research
Congenital Diaphragmatic Hernia Studies
article

Comparison of CT or MRI findings with histopathology in congenital lung malformations

Ueli Moehrlen, Robin Rey, Isabelle Ruchonnet-Métrailler, Christian Johannes Kellenberger, Anne‐Laure Rougemont, Thomas Schraner, Peter K. Bode, Isabelle Vidal, Méryle Laurent, Huy Leng Khov Eberhard, Mehrak Anooshiravani
article en

Abstract

Question addressed by the study What is the accuracy of postnatal thoracic computed tomography (CT) and magnetic resonance imaging (MRI) in the assessment of congenital lung malformations (CLM) compared to the pathological diagnosis? Materials/patients and methods This retrospective multicentre (two tertiary centres) study included patients from 2008 to 2019. Patients prenatally diagnosed with CLM underwent either CT or MRI prior to malformation surgical resection, and one experienced paediatric pathologist per centre evaluated pathology. Accuracy was assessed by comparing imaging-based diagnoses and characteristics with pathology. Interrater agreement was assessed using Cohen's kappa (k). Results Thirty-seven patients with 39 CLMs were included (20 CT, 19 MRI). Both modalities accurately localised lesion, but lesion characterization was inconsistent with pathology. CT demonstrated good size assessment and diagnostic accuracy for congenital pulmonary airway malformations (CPAM) (75%) and sequestration (90–95%) but frequently failed to detect emphysema (40%) and bronchial atresia (50%), whereas MRI showed perfect accuracy for sequestration (100%) but lower accuracy for other diagnoses (47% for CPAM, 58% for emphysema and 58–74% for bronchial atresia). Interrater agreement was high for both modalities (k=0.7–1.0) across most outcomes assessed. Answer to the question Both CT and MRI provide reliable and reproducible assessment of CLM in infants with good performances. CT confirms its strengths for size assessment and CPAM, while MRI achieved good diagnostic performances and represent a valuable radiation-free modality in experienced centre. Pathology remains the gold standard for final diagnosis.

ERJ Open Research
University of Zurich (CH), University Hospital of Zurich (CH), University Hospital of Geneva (CH), University Children's Hospital Zurich (CH)
Congenital Diaphragmatic Hernia Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon