Weakly Supervised Learning for HER2 Scoring in Cervical Cancer via Cross-Modal Knowledge Distillation: An Attentive Multi-Contrastive Alignment Framework Guided by Paired H&E and HER2 IHC Whole-Slide Images

Background/Objectives: Cervical cancer continues to pose a substantial global health burden, underscoring the need for accurate and early diagnostic tools. Although existing studies have demonstrated the feasibility of directly predicting human epidermal growth factor receptor 2 (HER2) scores from hematoxylin and eosin (H&E) whole-slide images (WSIs), the accuracy of these predictions remains limited. In this study, we investigated whether case-matched pairs of HER2 immunohistochemistry (IHC) WSIs and H&E WSIs can improve the HER2 score prediction. Methods: Case-matched pairs of H&E and HER2 IHC WSIs were independently encoded to generate separate sets of patch-level features. Then, within each patient-level cross-validation fold, a fold-specific HER2 IHC teacher was trained using only the IHC WSIs and labels from the four training folds and then frozen to guide a tumor-aware H&E student model through prediction distillation and multi-modal attentive contrastive learning between high- and low-attention patch groups. At the inference stage, the H&E student model predicted HER2 scores without any IHC input. Results: On the independent 126-case internal test set, under H&E-only inference, the proposed residual-fusion model trained on case-matched pairs of HER2 IHC and H&E WSIs achieved an accuracy of 0.6255, a macro-AUC of 0.6218, and a macro-F1 of 0.6103. By comparison, the model trained and evaluated using H&E-only WSIs achieved 0.5654, 0.5974, and 0.5465, respectively. In the separate IHC-assisted setting, when trained and evaluated on both H&E and IHC WSIs, the proposed residual-fusion model achieved an accuracy of 0.8080, a macro-AUC of 0.8685, and a macro-F1 of 0.7852. Although accuracy and macro-F1 were higher for the paired-training configuration under H&E-only inference, the macro-AUC remained modest. Conclusions: These findings suggest that paired IHC and H&E WSIs may provide useful training supervision for HER2 score prediction from H&E WSIs. Before clinical implementation can be considered, the model should be further evaluated in larger, independent, preferably multicenter external cohorts to assess its robustness and generalizability across institutions, scanners, staining protocols, and patient populations.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2026-11-26
DOI
https://doi.org/10.3390/diagnostics16233991
Primary Topic
AI in cancer detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Weakly Supervised Learning for HER2 Scoring in Cervical Cancer via Cross-Modal Knowledge Distillation: An Attentive Multi-Contrastive Alignment Framework Guided by Paired H&E and HER2 IHC Whole-Slide Images

Qian Liu, Miao Wu, Tao Hu
Diagnostics
AI in cancer detection
article

Weakly Supervised Learning for HER2 Scoring in Cervical Cancer via Cross-Modal Knowledge Distillation: An Attentive Multi-Contrastive Alignment Framework Guided by Paired H&E and HER2 IHC Whole-Slide Images

Qian Liu, Miao Wu, Tao Hu
article en

Abstract

Background/Objectives: Cervical cancer continues to pose a substantial global health burden, underscoring the need for accurate and early diagnostic tools. Although existing studies have demonstrated the feasibility of directly predicting human epidermal growth factor receptor 2 (HER2) scores from hematoxylin and eosin (H&E) whole-slide images (WSIs), the accuracy of these predictions remains limited. In this study, we investigated whether case-matched pairs of HER2 immunohistochemistry (IHC) WSIs and H&E WSIs can improve the HER2 score prediction. Methods: Case-matched pairs of H&E and HER2 IHC WSIs were independently encoded to generate separate sets of patch-level features. Then, within each patient-level cross-validation fold, a fold-specific HER2 IHC teacher was trained using only the IHC WSIs and labels from the four training folds and then frozen to guide a tumor-aware H&E student model through prediction distillation and multi-modal attentive contrastive learning between high- and low-attention patch groups. At the inference stage, the H&E student model predicted HER2 scores without any IHC input. Results: On the independent 126-case internal test set, under H&E-only inference, the proposed residual-fusion model trained on case-matched pairs of HER2 IHC and H&E WSIs achieved an accuracy of 0.6255, a macro-AUC of 0.6218, and a macro-F1 of 0.6103. By comparison, the model trained and evaluated using H&E-only WSIs achieved 0.5654, 0.5974, and 0.5465, respectively. In the separate IHC-assisted setting, when trained and evaluated on both H&E and IHC WSIs, the proposed residual-fusion model achieved an accuracy of 0.8080, a macro-AUC of 0.8685, and a macro-F1 of 0.7852. Although accuracy and macro-F1 were higher for the paired-training configuration under H&E-only inference, the macro-AUC remained modest. Conclusions: These findings suggest that paired IHC and H&E WSIs may provide useful training supervision for HER2 score prediction from H&E WSIs. Before clinical implementation can be considered, the model should be further evaluated in larger, independent, preferably multicenter external cohorts to assess its robustness and generalizability across institutions, scanners, staining protocols, and patient populations.

DiagnosticsVol. 16(23)
Xinjiang Medical University (CN)
AI in cancer detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon