Polyethylene liner design implications in reverse total shoulder arthroplasty

Background Although frequently deemed a subtle technical detail, polyethylene liner design fundamentally governs construct stability, biomechanics, and wear. Methods This review synthesizes current evidence on liner constraint metrics, joint kinematics, and wear dynamics. Results Significant variability exists in liner capture across manufacturers, with “standard” liners ranging from 35% to 63% and “retentive” liners ranging from 45% to 81% capture. The liner stability ratio indicates that 135° systems require a higher constraint (liner stability ratio [LSR] > 184%) than 155° systems (LSR 147–152%) to maintain equivalent stability. Liner thickness affects both lateralization and distalization simultaneously, though the liner contributes far less to total lateralization than the glenoid or humeral components. Highly cross-linked polyethylene shows approximately 56% less wear than conventional ultra-high-molecular-weight polyethylene, and vitamin E-enhanced polyethylene shows a 36–49% reduction in simulator studies. Constrained liners improve stability directionally, and the 26° motion cost measured in simulation is not reproduced in matched clinical cohorts. Asymmetric liner wear accounts for 60% of late dislocations. Discussion To optimize outcomes in reverse total shoulder arthroplasty, polyethylene liner constraint must be intentionally paired with humeral stem geometry rather than guided by manufacturer classification.

Authors

Institutions

Publication Details

Journal
Shoulder & Elbow
Published
2026-11-26
DOI
https://doi.org/10.1177/17585732261510340
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Polyethylene liner design implications in reverse total shoulder arthroplasty

Toufic Raja Jildeh, Dustin J. Kress, Zina Smadi, Kiran Sharma et al.
Shoulder & Elbow
Shoulder Injury and Treatment
article

Polyethylene liner design implications in reverse total shoulder arthroplasty

Toufic Raja Jildeh, Dustin J. Kress, Zina Smadi, Kiran Sharma, Ayush Ippalapelli
article en

Abstract

Background Although frequently deemed a subtle technical detail, polyethylene liner design fundamentally governs construct stability, biomechanics, and wear. Methods This review synthesizes current evidence on liner constraint metrics, joint kinematics, and wear dynamics. Results Significant variability exists in liner capture across manufacturers, with “standard” liners ranging from 35% to 63% and “retentive” liners ranging from 45% to 81% capture. The liner stability ratio indicates that 135° systems require a higher constraint (liner stability ratio [LSR] > 184%) than 155° systems (LSR 147–152%) to maintain equivalent stability. Liner thickness affects both lateralization and distalization simultaneously, though the liner contributes far less to total lateralization than the glenoid or humeral components. Highly cross-linked polyethylene shows approximately 56% less wear than conventional ultra-high-molecular-weight polyethylene, and vitamin E-enhanced polyethylene shows a 36–49% reduction in simulator studies. Constrained liners improve stability directionally, and the 26° motion cost measured in simulation is not reproduced in matched clinical cohorts. Asymmetric liner wear accounts for 60% of late dislocations. Discussion To optimize outcomes in reverse total shoulder arthroplasty, polyethylene liner constraint must be intentionally paired with humeral stem geometry rather than guided by manufacturer classification.

Shoulder & Elbow
Texas Children's Hospital (US), Michigan State University (US)
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon