Simulation-guided design of an electricity-free, locally sourced heater for LAMP-based tuberculosis and malaria testing in sub- Saharan Africa
Background: The WHO recommends loop-mediated isothermal amplification (LAMP) for tuberculosis, and it is also the method used for malaria, but it still requires a stable heat source of 60–68°C. In sub-Saharan Africa 15% of health facilities are without electricity, while just 40% are supplied with electricity in a reliable manner. However, chemical heaters that incorporate an exothermic reaction and a phase change material (PCM) can eliminate that requirement, but existing designs have been based on imported magnesium–iron alloy and specialty paraffin, and they have been tuned through experimentation and they have been tested under limited ambient conditions. No research has forecasted the performance of such a heater as a diagnostic (as opposed to being a thermostat) throughout the climates of the area. Methods: An open-source, axisymmetric finite-element model (scikit-fem) of a cup-type heater that integrates fuel reaction kinetics, steam venting, enthalpy-method PCM and conductive filler, as well as heat loss to the environment was developed. A semi-mechanistic LAMP model, incorporating temperature-dependent amplification and Bst polymerase inactivation, and stochastic template initiation, is used to simulate the sample temperature and the resulting time-to-positive and 95% limit of detection (LoD95) after a fixed read time of 60 minutes for each heater run. The solver was compared with the analytical Stefan solution and checked for mesh, time-step and energy convergence. Quicklime (CaO) was compared to Mg–Fe alloy; palm derived palmitic acid and raw beeswax were compared with commercial 64 °C paraffin. We then investigated the mapping of the dose and climate windows (5–45 °C, still air to wind), explored the possibility of insulating, water metering, and conductive filler, and estimated the reliability by Monte Carlo simulation in four representative climate zones of Africa, followed by a Sobol global sensitivity analysis. The total number of coupled simulations run was over 7,000. Results: The 12 g charge of quicklime was able to bring a 25-µL sample to 60 °C in 5.5 min and maintain that temperature for more than 1 h at 25 °C, compared with 10 min for an ideal 65 °C block. A 12 g charge of quicklime was able to raise a 25-µL sample to 60 °C in 5.5 min and hold it there for more than 1 h at 25 °C, compared to 10 min for an ideal 65 °C block. All designs would not have made it to 82-96 °C without the inclusion of PCM. Raw beeswax melted over a wide range and only passed 7 of 36 climate conditions, while palmitic acid passed 34 of 36, and imported paraffin passed 35 of 36. The energy density of quicklime was found to be low and hence dose errors of ±18% were quite tolerable over the full 5-45 °C range, compared to ±4% for Mg-Fe. In colder environments, thicker insulation was beneficial, but in hot environments, it was not. For realistic material and manufacturing variability, the fixed quicklime design yielded valid results in 90.8% (95% CI 88.3–92.9%) of the simulated tests and a climate-indexed fuel sachet increased this to 94.2% (95% CI 92.0–95.8%). Ambient temperature was the most sensitive parameter in the global sensitivity analysis, followed by the fuel dose and fuel purity. Conclusions: In simulation, a sub-Saharan Africa-produced heater can achieve LAMP performance similar to a laboratory heat block in its various climates without electricity. The model provides specific design principles and a free tool that is reproducible to modify the heater for other assays. The next step is bench validation by thermocouple logging and LAMP testing.
Authors
- Deborah O. Daramola
- Emmanuel Dominic Ephraim (ORCID: https://orcid.org/0009-0007-2426-2709)
- Benedict Olumhense Adoghe
- Ademola Samson Adekola
- Oghenefejiro Omonigho Ederhi
- Aruomachi Kingsley Olumati
- Omotayo Tolulope Motunrayo
Institutions
- Achievers University (NG)
- State University of Medical and Applied Sciences (NG)
Publication Details
- Journal
- Research Square
- Published
- 2026-11-26
- DOI
- https://doi.org/10.21203/rs.3.rs-11730404/v1
- Primary Topic
- Biosensors and Analytical Detection
- Type
- preprint