Separating Sensor Drift from Supplier-Lot and Tool-Wear Drift in Sensor-Driven Assembly: A Reference-Anchored Monitoring and Attribution Scheme
Changes in measurements collected during assembly do not always reflect changes in the parts themselves. A drifting sensor, a nonconforming supplier lot, and tool wear can produce similar signals, particularly when they occur together. This study presents a reference-anchored approach to distinguish these sources. Periodic measurements from an independent gauge are used to estimate sensor error and correct inline readings when needed. A hierarchical model and separate cumulative sum (CUSUM) charts then track supplier-lot effects and tool wear. The approach was tested on a simulated assembly line with known causes of drift, using 1,000 runs per scenario and thresholds calibrated on 8,000 drift-free runs. When sensor drift and supplier failure occurred together, the method identified the correct set of causes in 74% of runs (95% CI: 72–77%), while neither comparison method achieved this. Without reference measurements, sensor drift was incorrectly attributed to a supplier in 89% of sensor-only runs. For supplier-only failures, accuracy was similar to EWMA (65% versus 67%). In UCI gas-sensor data, reference correction every five samples reduced prediction RMSE from 1.91 to 0.42. NASA milling data showed that spindle current did not predict wear better than cutting time.
Authors
- Kesava Abisek Rengaraju Senthamil Selvi
Publication Details
- Journal
- Preprints.org
- Published
- 2026-11-26
- DOI
- https://doi.org/10.20944/preprints202611.2696.v1
- Primary Topic
- Advanced Statistical Process Monitoring
- Type
- preprint