Automatic cerebral angiographic perfusion analysis

Purpose: To automate anatomical localization for angiographic perfusion and evaluate agreement with manual processing between biplane projections in a held-out external cohort. Methods: Separate anteroposterior (AP) and lateral projection hemisphere and internal carotid artery (ICA) models used DeepLabv3+ with ResNet50 encoders. Development used patient-separated training, validation, and testing. External patients were excluded from fitting and model selection. Automated pipeline and manual-pipeline perfusion shared downstream calculations. Eligible acquisitions contained at least 7 seconds of data after bolus arrival. Segmentation metrics and Bland-Altman analyses evaluated mean transit time (MTT) and time to maximum of the residue function (Tmax). Results: External segmentation testing included 353 runs from 73 patients. Patient-mean hemisphere Dice was 0.959 (95% CI, 0.952-0.965) in AP and 0.965 (0.960-0.969) in lateral views while ICA Dice was 0.635 (0.617-0.650) and 0.558 (0.534-0.579). Manually processed perfusion comparisons included 165 external runs from 52 patients. Mean absolute differences (95% CI) were 0.39 (0.31-0.47) and 0.32 (0.25-0.40) seconds for AP and lateral MTT, and 0.23 (0.15-0.35) and 0.31 (0.17-0.51) seconds for Tmax. Among 220 external cohort biplane pairs from 61 patients, mean absolute differences were 0.48 seconds (95% CI, 0.42-0.53) for MTT and 0.53 seconds (0.35-0.75) for Tmax. Repeated-measures mean biases (95% CI) were -0.07 (-0.19 to 0.05) and 0.16 seconds (-0.08 to 0.40), with 95% limits of agreement of -1.38 to 1.24 and -2.65 to 2.97 seconds respectively. Conclusion: Our automated perfusion pipeline showed favorable agreement with manually processed results in the external validation cohort. Independently processed biplane views had small average bias.

Authors

Institutions

Publication Details

Journal
medRxiv
Published
2026-11-25
DOI
https://doi.org/10.64898/2026.11.24.26368862
Primary Topic
Medical Image Segmentation Techniques
Type
preprint
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
preprint

Automatic cerebral angiographic perfusion analysis

Kyle A. Lyman, Ona Wu, Nils Petersen, David Y. Chung et al.
medRxiv
Medical Image Segmentation Techniques
preprint

Automatic cerebral angiographic perfusion analysis

Kyle A. Lyman, Ona Wu, Nils Petersen, David Y. Chung, Ryan Matthew Hebert, Nanthiya Sujijantarat, Charles Christian Matouk, Lily Pwint Thinzar
preprint en

Abstract

Purpose: To automate anatomical localization for angiographic perfusion and evaluate agreement with manual processing between biplane projections in a held-out external cohort. Methods: Separate anteroposterior (AP) and lateral projection hemisphere and internal carotid artery (ICA) models used DeepLabv3+ with ResNet50 encoders. Development used patient-separated training, validation, and testing. External patients were excluded from fitting and model selection. Automated pipeline and manual-pipeline perfusion shared downstream calculations. Eligible acquisitions contained at least 7 seconds of data after bolus arrival. Segmentation metrics and Bland-Altman analyses evaluated mean transit time (MTT) and time to maximum of the residue function (Tmax). Results: External segmentation testing included 353 runs from 73 patients. Patient-mean hemisphere Dice was 0.959 (95% CI, 0.952-0.965) in AP and 0.965 (0.960-0.969) in lateral views while ICA Dice was 0.635 (0.617-0.650) and 0.558 (0.534-0.579). Manually processed perfusion comparisons included 165 external runs from 52 patients. Mean absolute differences (95% CI) were 0.39 (0.31-0.47) and 0.32 (0.25-0.40) seconds for AP and lateral MTT, and 0.23 (0.15-0.35) and 0.31 (0.17-0.51) seconds for Tmax. Among 220 external cohort biplane pairs from 61 patients, mean absolute differences were 0.48 seconds (95% CI, 0.42-0.53) for MTT and 0.53 seconds (0.35-0.75) for Tmax. Repeated-measures mean biases (95% CI) were -0.07 (-0.19 to 0.05) and 0.16 seconds (-0.08 to 0.40), with 95% limits of agreement of -1.38 to 1.24 and -2.65 to 2.97 seconds respectively. Conclusion: Our automated perfusion pipeline showed favorable agreement with manually processed results in the external validation cohort. Independently processed biplane views had small average bias.

medRxiv
Yale University (US), Massachusetts General Hospital (US)
Medical Image Segmentation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.