NUMERICAL SIMULATION OF WATER MIST FLOW CHARACTERISTICS EFFECTS ON TEMPERATURE AND GASEOUS CONCENTRATIONS IN A REAL ROAD TUNNEL MODEL

Water mist systems have emerged as an effective alternative to conventional sprinkler systems for tunnel fire protection due to their lower water consumption, enhanced heat absorption capability, and improved environmental performance. However, previous tunnel fire studies have mainly focused on high-pressure water mist systems and have rarely investigated the combined effects of spray characteristics on both thermal behavior and hazardous gas concentrations within evacuation zones. In this study, a numerical investigation was conducted using the Fire Dynamic Simulator (FDS) coupled with a Large Eddy Simulation (LES) approach to evaluate the performance of water mist systems in a full-scale road tunnel fire scenario. A 15 MW vehicle fire was simulated to examine the effects of injection pressure (12, 34, and 70 bar), spray cone angle, and median droplet diameter on temperature reduction and species concentration distributions, particularly CO₂ and O₂. The results demonstrated that increasing injection pressure, widening the spray angle, and reducing droplet diameter significantly enhanced fire suppression performance. The maximum gas temperature within the critical downstream region decreased from approximately 370 °C to below 100 °C under high-pressure conditions with fine droplets and wider spray coverage. In addition, CO₂ concentration decreased from approximately 0.04 mol/mol to 0.006–0.012 mol/mol, while O₂ concentration improved to approximately 0.16–0.18 mol/mol, indicating enhanced tunnel tenability and evacuation conditions. The findings demonstrate that the coupled optimization of pressure, droplet size, and spray angle plays a critical role in improving thermal attenuation and combustion gas control in tunnel fires.

Authors

Institutions

Publication Details

Journal
Journal of Al-Azhar University Engineering Sector
Published
2026-11-26
DOI
https://doi.org/10.21608/auej.2026.509012.2177
Primary Topic
Fire dynamics and safety research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

NUMERICAL SIMULATION OF WATER MIST FLOW CHARACTERISTICS EFFECTS ON TEMPERATURE AND GASEOUS CONCENTRATIONS IN A REAL ROAD TUNNEL MODEL

Nabil A. Mahmoud, Ashraf M. Hamed, Ahmed Hussein, MOAZ BAKRY
Journal of Al-Azhar University Engineering Sector
Fire dynamics and safety research
article

NUMERICAL SIMULATION OF WATER MIST FLOW CHARACTERISTICS EFFECTS ON TEMPERATURE AND GASEOUS CONCENTRATIONS IN A REAL ROAD TUNNEL MODEL

Nabil A. Mahmoud, Ashraf M. Hamed, Ahmed Hussein, MOAZ BAKRY
article en

Abstract

Water mist systems have emerged as an effective alternative to conventional sprinkler systems for tunnel fire protection due to their lower water consumption, enhanced heat absorption capability, and improved environmental performance. However, previous tunnel fire studies have mainly focused on high-pressure water mist systems and have rarely investigated the combined effects of spray characteristics on both thermal behavior and hazardous gas concentrations within evacuation zones. In this study, a numerical investigation was conducted using the Fire Dynamic Simulator (FDS) coupled with a Large Eddy Simulation (LES) approach to evaluate the performance of water mist systems in a full-scale road tunnel fire scenario. A 15 MW vehicle fire was simulated to examine the effects of injection pressure (12, 34, and 70 bar), spray cone angle, and median droplet diameter on temperature reduction and species concentration distributions, particularly CO₂ and O₂. The results demonstrated that increasing injection pressure, widening the spray angle, and reducing droplet diameter significantly enhanced fire suppression performance. The maximum gas temperature within the critical downstream region decreased from approximately 370 °C to below 100 °C under high-pressure conditions with fine droplets and wider spray coverage. In addition, CO₂ concentration decreased from approximately 0.04 mol/mol to 0.006–0.012 mol/mol, while O₂ concentration improved to approximately 0.16–0.18 mol/mol, indicating enhanced tunnel tenability and evacuation conditions. The findings demonstrate that the coupled optimization of pressure, droplet size, and spray angle plays a critical role in improving thermal attenuation and combustion gas control in tunnel fires.

Journal of Al-Azhar University Engineering Sector
Ain Shams University (EG)
Fire dynamics and safety research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
NUMERICAL SIMULATION OF WATER MIST FLOW CHARACTERISTICS EFFECTS ON TEMPERATURE AND GASEOUS CONCENTRATIONS IN A REAL ROAD TUNNEL MODEL — Nabil A. Mahmoud, Ashraf M. Hamed, et al. · Journal of Al-Azhar University Engineering Sector (2026) | TGRS Research Map | TGRS