Calcification Remains Detrimental Despite Post‐Procedural Lumen Expansion After Drug‐Coated Balloon Treatment of Femoropopliteal Artery Lesions: Results From a Multicenter Retrospective Registry
Background and Aims Severe calcification is a classical predictor of restenosis after endovascular therapy (EVT) using drug‐coated balloons (DCB) for femoropopliteal artery (FPA) disease. This study investigated whether the adverse effect of calcification was primarily mediated via insufficient post‐procedural lumen expansion. Materials and Methods This multicenter retrospective analysis included 601 patients with 727 FPA lesions treated with intravascular ultrasound (IVUS)‐guided EVT using DCB. The characteristics of calcium deposits included bilateral calcification, length ≥ 5 cm, cross‐sectional angle, and nodular calcification (NC). The primary endpoint was restenosis during follow‐up, defined as diameter stenosis of > 50% with peak systolic velocity ratio of > 2.4 or occlusion assessed by duplex ultrasonography. Associations between calcification characteristics and restenosis were evaluated using multivariate Poisson regression models before and after adjusting for post‐procedural minimum lumen area (MLA). Results During 1.57 thousand person‐years of follow‐up, 260 restenosis occurred, corresponding to an incidence rate of 165 per 1000 person‐years. In multivariable analysis, calcification length ≥ 5 cm (incidence risk ratio [IRR], 1.51; p = 0.014) and NC (IRR, 1.48; p = 0.018) were independently associated with restenosis. However, additional adjustment for MLA resulted in only minimal attenuation of association between calcification and restenosis (4.0% for calcification length ≥ 5 cm and 6.8% for NC; both p > 0.05). Larger post‐procedural MLA itself was independently associated with lower restenosis risk (IRR per 10 mm 2 increase, 0.70; p = 0.028). No significant interaction was observed between MLA and calcification characteristics. Conclusion Association of extensive calcification and NC with restenosis after DCB treatment might be unlikely explained by insufficient post‐procedural lumen expansion.
Authors
- Yo Iwata (ORCID: https://orcid.org/0000-0002-6969-4456)
- Shigeru Toyoda (ORCID: https://orcid.org/0000-0002-8260-833X)
- Shinsuke Mori (ORCID: https://orcid.org/0000-0001-9037-867X)
- Kazuki Tobita (ORCID: https://orcid.org/0000-0002-1913-6894)
- Mitsuyoshi Takahara (ORCID: https://orcid.org/0000-0001-5105-041X)
- Tatsuya Nakama (ORCID: https://orcid.org/0000-0001-9107-6438)
- Kazunori Horie (ORCID: https://orcid.org/0000-0002-8614-7729)
- Masashi Sakuma (ORCID: https://orcid.org/0000-0002-3892-0799)
- Naoki Hayakawa (ORCID: https://orcid.org/0000-0002-4168-2808)
- Kenji Suzuki (ORCID: https://orcid.org/0000-0001-6998-3816)
- Norio Tada (ORCID: https://orcid.org/0000-0002-1304-5836)
Institutions
- Saiseikai Central Hospital (JP)
- Funabashi Municipal Medical Center (JP)
- Asahi General Hospital (JP)
- Shonan Kamakura General Hospital (JP)
- Saiseikai Yokohama Eastern Hospital (JP)
- Sendai Kousei Hospital (JP)
- Dokkyo Medical University (JP)
- The University of Osaka (JP)
Publication Details
- Journal
- Catheterization and Cardiovascular Interventions
- Published
- 2026-11-25
- DOI
- https://doi.org/10.1002/ccd.71055
- Primary Topic
- Peripheral Artery Disease Management
- Type
- article
- Field-Weighted Citation Impact
- 0.00