Systemwide Quality Improvement Strategy to Reduce Nitrous Oxide Environmental Emissions in a Brazilian Health Network

BACKGROUND: Nitrous oxide (N₂O) is a potent greenhouse gas commonly used in perioperative care and with substantial environmental impact. This study evaluated a systemwide quality improvement (QI) initiative designed to achieve 85% reduction in carbon dioxide equivalent (CO₂e) emissions attributable to N₂O across a large private Brazilian hospital network. METHODS: A multicenter before-after QI protocol was implemented across 54 hospitals between September/2024 and December/2025 using sequential Plan-Do-Study-Act cycles: cycle 1 delivered a systemwide educational program; cycle 2 introduced operational restriction of N₂O through disconnection of anesthesia workstations from the central pipeline with protocol-guided use limited to pediatric inhalational anesthesia induction; and cycle 3 implemented hospital-level benchmarking with structured feedback and leadership engagement. RESULTS: Baseline mean N₂O consumption per surgical procedure was 0.7 ± 0.9 kg, with total network consumption of 15,954 kg/month. Hospital operational age was not associated with baseline consumption intensity (β = 0.008; 95% CI - 0.001 to 0.02; p = 0.11). At the network level, baseline N₂O-related CO₂e emissions showed a median of 4.23 kt (IQR 4.11-4.67). Following implementation, median monthly emissions decreased to 0.29 kt (IQR 0.24-0.66). Mean monthly emissions decreased from 4.36 to 0.45 kt, an estimated absolute reduction of 3.90 kt (95% CI 3.60-4.21) and a relative reduction of 89.6%. No adverse events related to N₂O restriction were reported through the institutional incident reporting system. CONCLUSION: A systemwide QI strategy was associated with an 89.6% reduction in N₂O-attributable CO₂e emissions across 54 hospitals, demonstrating that N₂O reduction can be incorporated into routine perioperative governance.

Authors

Institutions

Publication Details

Journal
International Journal for Quality in Health Care
Published
2026-11-26
DOI
https://doi.org/10.1093/intqhc/mzag199
Primary Topic
Healthcare Quality and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Systemwide Quality Improvement Strategy to Reduce Nitrous Oxide Environmental Emissions in a Brazilian Health Network

Leopoldo Muniz da Silva, Ana Cláudia Fernandes Araújo, Leandro Reis Tavares, Fernando Nardy Bellicieri et al.
International Journal for Quality in Health Care
Healthcare Quality and Management
article

Systemwide Quality Improvement Strategy to Reduce Nitrous Oxide Environmental Emissions in a Brazilian Health Network

Leopoldo Muniz da Silva, Ana Cláudia Fernandes Araújo, Leandro Reis Tavares, Fernando Nardy Bellicieri, Rafael Souza Fava Nersessian, Glenio Bitencourt Mizubuti, Helidea de Oliveira Lima, Saullo Queiroz Silveira, Rodrigo Gavina da Cruz
article en

Abstract

BACKGROUND: Nitrous oxide (N₂O) is a potent greenhouse gas commonly used in perioperative care and with substantial environmental impact. This study evaluated a systemwide quality improvement (QI) initiative designed to achieve 85% reduction in carbon dioxide equivalent (CO₂e) emissions attributable to N₂O across a large private Brazilian hospital network. METHODS: A multicenter before-after QI protocol was implemented across 54 hospitals between September/2024 and December/2025 using sequential Plan-Do-Study-Act cycles: cycle 1 delivered a systemwide educational program; cycle 2 introduced operational restriction of N₂O through disconnection of anesthesia workstations from the central pipeline with protocol-guided use limited to pediatric inhalational anesthesia induction; and cycle 3 implemented hospital-level benchmarking with structured feedback and leadership engagement. RESULTS: Baseline mean N₂O consumption per surgical procedure was 0.7 ± 0.9 kg, with total network consumption of 15,954 kg/month. Hospital operational age was not associated with baseline consumption intensity (β = 0.008; 95% CI - 0.001 to 0.02; p = 0.11). At the network level, baseline N₂O-related CO₂e emissions showed a median of 4.23 kt (IQR 4.11-4.67). Following implementation, median monthly emissions decreased to 0.29 kt (IQR 0.24-0.66). Mean monthly emissions decreased from 4.36 to 0.45 kt, an estimated absolute reduction of 3.90 kt (95% CI 3.60-4.21) and a relative reduction of 89.6%. No adverse events related to N₂O restriction were reported through the institutional incident reporting system. CONCLUSION: A systemwide QI strategy was associated with an 89.6% reduction in N₂O-attributable CO₂e emissions across 54 hospitals, demonstrating that N₂O reduction can be incorporated into routine perioperative governance.

International Journal for Quality in Health Care
Universidade de São Paulo (BR), Queen's University (CA), D’Or Institute for Research and Education (BR), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (BR)
Healthcare Quality and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon