Perturb-and-Observe PTO Force Control for Grid-Connected Wave Energy Converters with BESS-Based Power Smoothing

Wave energy converters (WECs) must simultaneously maximize the energy absorbed from an irregular sea and deliver it to the grid as a smooth, standards-compliant power flow—two objectives that conventional PTO controllers address only partially. This paper proposes an adaptive perturb-and-observe (P&O) power-take-off (PTO) force-control strategy for a grid-connected, battery-supported heaving point-absorber WEC, and evaluates it within a complete wave-to-grid model. Unlike damping-only P&O schemes, the proposed coordinated dual-objective algorithm adaptively tunes both the PTO damping and the reactive stiffness coefficient online, using a Hilbert-envelope-based absorbed-power objective and a normalized excitation-force–velocity alignment metric, thereby retuning the device towards resonance without requiring hydrodynamic impedance information for PTO parameter optimization or wave-force prediction. The machine-side converter, a DC link with an integrated battery energy storage system (BESS), and a grid-side converter complete the wave-to-grid chain. The proposed dual-parameter P&O (DP-PO) strategy is benchmarked against damping-only P&O (D-PO), FLL-based resistive loading (FLL-RL), and scaled approximate complex-conjugate (S-ACC) control across three JONSWAP sea states. DP-PO attains the highest capture width ratio in SS1 and SS2 (up to 0.380) and achieves comparable performance to S-ACC in SS3 (0.253 versus 0.257), at the cost of higher peak PTO force, buoy excursion, and storage utilization, while the BESS-supported system achieves a power smoothing index of 0.855–0.925 under DP-PO across the investigated sea states. The results quantify a clear, multi-criteria trade-off and show that model-assisted PTO parameter adaptation can achieve competitive energy capture relative to a scaled model-based reactive-control benchmark within a grid-connected system.

Authors

Institutions

Publication Details

Journal
Processes
Published
2026-11-26
DOI
https://doi.org/10.3390/pr14233815
Primary Topic
Wave and Wind Energy Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Perturb-and-Observe PTO Force Control for Grid-Connected Wave Energy Converters with BESS-Based Power Smoothing

Addy Wahyudie, Mohammed Jama
Processes
Wave and Wind Energy Systems
article

Perturb-and-Observe PTO Force Control for Grid-Connected Wave Energy Converters with BESS-Based Power Smoothing

Addy Wahyudie, Mohammed Jama
article en

Abstract

Wave energy converters (WECs) must simultaneously maximize the energy absorbed from an irregular sea and deliver it to the grid as a smooth, standards-compliant power flow—two objectives that conventional PTO controllers address only partially. This paper proposes an adaptive perturb-and-observe (P&O) power-take-off (PTO) force-control strategy for a grid-connected, battery-supported heaving point-absorber WEC, and evaluates it within a complete wave-to-grid model. Unlike damping-only P&O schemes, the proposed coordinated dual-objective algorithm adaptively tunes both the PTO damping and the reactive stiffness coefficient online, using a Hilbert-envelope-based absorbed-power objective and a normalized excitation-force–velocity alignment metric, thereby retuning the device towards resonance without requiring hydrodynamic impedance information for PTO parameter optimization or wave-force prediction. The machine-side converter, a DC link with an integrated battery energy storage system (BESS), and a grid-side converter complete the wave-to-grid chain. The proposed dual-parameter P&O (DP-PO) strategy is benchmarked against damping-only P&O (D-PO), FLL-based resistive loading (FLL-RL), and scaled approximate complex-conjugate (S-ACC) control across three JONSWAP sea states. DP-PO attains the highest capture width ratio in SS1 and SS2 (up to 0.380) and achieves comparable performance to S-ACC in SS3 (0.253 versus 0.257), at the cost of higher peak PTO force, buoy excursion, and storage utilization, while the BESS-supported system achieves a power smoothing index of 0.855–0.925 under DP-PO across the investigated sea states. The results quantify a clear, multi-criteria trade-off and show that model-assisted PTO parameter adaptation can achieve competitive energy capture relative to a scaled model-based reactive-control benchmark within a grid-connected system.

ProcessesVol. 14(23)
Abu Dhabi University (AE), United Arab Emirates University (AE)
Wave and Wind Energy Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Perturb-and-Observe PTO Force Control for Grid-Connected Wave Energy Converters with BESS-Based Power Smoothing — Addy Wahyudie, Mohammed Jama · Processes (2026) | TGRS Research Map | TGRS