Predictive direct power control and adaptive extended Kalman filter-based state-of-charge estimation for a bidirectional on-board EV battery charger
This paper presents a modeling, control and state-estimation framework for a bidirectional on-board electric-vehicle charger operating in grid-to-vehicle (G2V) and vehicle-to-grid (V2G) modes. The charger combines a three-level neutral-point-clamped (NPC) AC-DC converter, controlled by predictive direct power control with space-vector modulation (P-DPC-SVM), and a bidirectional DC-DC converter described by a single average model valid in buck and boost operation. The predictive law uses the grid voltage averaged over the sampling period and a slow bias correction that acts only on the deviation from a first-order reference model and is frozen during modulator saturation, so that the power response is first order with negligible overshoot. The DC-bus voltage loop is designed by pole placement on the series equivalent capacitance, with a feedforward of the power drawn by the DC-DC stage. The state of charge is estimated by an adaptive extended Kalman filter (AEKF) built on a second-order equivalent circuit, whose model deliberately differs from the simulated battery (nonlinear open-circuit voltage, shifted parameters, capacity fade). The evaluation combines an energy-consistent average model, used for long duty cycles and grid-code scenarios, with a switched NPC model including semiconductor losses, used to quantify efficiency and to compare the proposed controller with voltage-oriented PI control and conventional switching-table direct power control. The results show that the proposed controller matches the dynamics of a voltage-oriented controller of equal bandwidth with a lower power cross-coupling for small reference steps, at fixed switching frequency and with a much lower current distortion than switching-table control; that the charger efficiency remains high in both power-flow directions; and that the benefit of the AEKF over a classical EKF is large under time-varying noise and outliers but shrinks when the estimator model is mismatched, which identifies model identification as the dominant factor for estimation accuracy.
Authors
- Kada Hartani (ORCID: https://orcid.org/0000-0001-7396-1839)
- Abdelkader Merah (ORCID: https://orcid.org/0000-0001-7481-1736)
- Aouadj Norediene
Institutions
- Université Oran 1 Ahmed Ben Bella (DZ)
- Université de Saida Dr.Moulay Tahar (DZ)
Publication Details
- Journal
- Proceedings of the Institution of Mechanical Engineers Part D Journal of Automobile Engineering
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1177/09544070261508713
- Primary Topic
- Advanced DC-DC Converters
- Type
- article
- Field-Weighted Citation Impact
- 0.00