Effect of different gutta-percha tip-trimming techniques on apical sealer percentage in single-cone obturation: a comparative in-vitro study
To compare the apical sealer percentage, as an indirect indicator of apical marginal adaptation, among untrimmed, blade-trimmed, and Cut&Fit-trimmed gutta-percha cones in single-cone obturation. This study was conducted on 45 three-dimensional-printed teeth, reproduced from a 3D model derived from a prepared natural premolar scan. The samples were randomly assigned to three equal groups according to the cone-tip condition ( n = 15 per group): G1, untrimmed factory-manufactured 30/0.04 gutta-percha cones; G2, 25/0.04 cones blade-trimmed to a nominal 30/0.04 tip; and G3, 25/0.04 cones trimmed to a nominal 30/0.04 tip with the Cut&Fit device. After obturation with bioceramic sealer, each sample in each group was sectioned perpendicularly to the long axis at 2 mm from the apex and then examined under a stereomicroscope. Images were analysed using specialised software to calculate the percentage of sealer area relative to the total obturated canal area at the apical cross-section (the primary outcome), and this value was compared among groups to compare the three cone-tip conditions. Because Levene’s test indicated unequal variances, Welch’s ANOVA with Games–Howell post-hoc comparisons was used as the principal analysis, with conventional one-way ANOVA and Tukey’s HSD as complementary analyses (α = 0.05). The blade-trimmed group showed the highest mean sealer percentage (37.65% ± 10.05), followed by the Cut&Fit-trimmed group (28.27% ± 10.33), while the untrimmed (control) group showed the lowest (14.24% ± 4.31). Welch’s ANOVA revealed a significant difference among the groups (F(2, 23.68) = 39.86, p < 0.001). In the Games–Howell comparisons, the mean sealer percentage exceeded that of the untrimmed group by 23.41% points in the blade-trimmed group (95% CI 16.24 to 30.59; p < 0.001) and by 14.03% points in the Cut&Fit-trimmed group (95% CI 6.68 to 21.38; p < 0.001). The blade-trimmed group exceeded the Cut&Fit-trimmed group by 9.39% points (95% CI 0.18 to 18.59; p = 0.045), a borderline and imprecisely estimated difference. Conventional ANOVA and Tukey’s HSD yielded consistent results. Both trimmed cone-tip conditions were associated with a higher sealer percentage at the 2-mm apical cross-section than untrimmed factory-manufactured cones. The lower sealer percentage with the Cut&Fit device than with blade trimming was of borderline significance and imprecisely estimated, and should be interpreted cautiously. As sealer percentage at a single cross-section is an indirect indicator, these findings suggest, but do not directly demonstrate, differences in apical marginal adaptation, and do not establish differences in sealing ability.
Authors
- Samar Akil (ORCID: https://orcid.org/0000-0002-1457-1125)
- Yasser Alsayed Tolibah (ORCID: https://orcid.org/0000-0001-5498-9991)
- Saad Hammami
Institutions
- Damascus University (SY)
Publication Details
- Journal
- BMC Oral Health
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1186/s12903-026-10466-4
- Primary Topic
- Endodontics and Root Canal Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00