Statistical optimization of silicon–CNT MEMS pressure sensor design for enhanced low-pressure sensing performance

The growing need for highly sensitive and linear MEMS pressure sensors in biomedical applications has drawn significant attention, particularly for monitoring low-pressure ranges (1–5 kPa) relevant to intra-body conditions such as intracranial pressure (ICP) and intraocular pressure (IOP). These pressures often exhibit oscillatory behavior, requiring sensors with superior sensitivity and reliable performance. Silicon and carbon nanotubes (CNTs), known for their excellent mechanical strength and electrical conductivity, are ideal candidates for designing high-performance nanosensors. This study focuses on optimizing key design parameters—diaphragm length, diaphragm thickness, bossed size, and operating temperature—to enhance sensor sensitivity and linearity. Using Response Surface Methodology (RSM) and validating results with Analysis of Variance (ANOVA), simulations were performed in ANSYS to analyze the impact of these factors. Findings revealed that diaphragm length, thickness, and temperature play a critical role in improving sensitivity, while bossed size significantly affects linearity. The optimal configuration—10 µm diaphragm thickness, 1200 µm diaphragm length, 20 °C temperature, and 300 µm bossed size—achieved a sensitivity of 28.042 mV/kPa and nonlinearity of 0.1884%. This work offers valuable insights for developing next-generation low-pressure sensors and encourages further exploration of alternative semiconductor materials for diaphragm and piezoresistive elements to attain enhanced biomedical sensing performance.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2026-11-26
DOI
https://doi.org/10.1038/s41598-026-76805-1
Primary Topic
Advanced MEMS and NEMS Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Statistical optimization of silicon–CNT MEMS pressure sensor design for enhanced low-pressure sensing performance

Rekha Devi, Balwinder Singh, Aditi Sharma, Raj Kumar
Scientific Reports
Advanced MEMS and NEMS Technologies
article

Statistical optimization of silicon–CNT MEMS pressure sensor design for enhanced low-pressure sensing performance

Rekha Devi, Balwinder Singh, Aditi Sharma, Raj Kumar
article en

Abstract

The growing need for highly sensitive and linear MEMS pressure sensors in biomedical applications has drawn significant attention, particularly for monitoring low-pressure ranges (1–5 kPa) relevant to intra-body conditions such as intracranial pressure (ICP) and intraocular pressure (IOP). These pressures often exhibit oscillatory behavior, requiring sensors with superior sensitivity and reliable performance. Silicon and carbon nanotubes (CNTs), known for their excellent mechanical strength and electrical conductivity, are ideal candidates for designing high-performance nanosensors. This study focuses on optimizing key design parameters—diaphragm length, diaphragm thickness, bossed size, and operating temperature—to enhance sensor sensitivity and linearity. Using Response Surface Methodology (RSM) and validating results with Analysis of Variance (ANOVA), simulations were performed in ANSYS to analyze the impact of these factors. Findings revealed that diaphragm length, thickness, and temperature play a critical role in improving sensitivity, while bossed size significantly affects linearity. The optimal configuration—10 µm diaphragm thickness, 1200 µm diaphragm length, 20 °C temperature, and 300 µm bossed size—achieved a sensitivity of 28.042 mV/kPa and nonlinearity of 0.1884%. This work offers valuable insights for developing next-generation low-pressure sensors and encourages further exploration of alternative semiconductor materials for diaphragm and piezoresistive elements to attain enhanced biomedical sensing performance.

Scientific ReportsVol. 16(1)
Chandigarh University (IN), Centre for Development of Advanced Computing (IN), Symbiosis International (Deemed University) (IN), Manav Rachna International Institute of Research and Studies (IN)
Advanced MEMS and NEMS Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Statistical optimization of silicon–CNT MEMS pressure sensor design for enhanced low-pressure sensing performance — Rekha Devi, Balwinder Singh, et al. · Scientific Reports (2026) | TGRS Research Map | TGRS