Average real variability is more resilient than standard deviation to shortened recording windows in resting beat-to-beat hemodynamics

Beat-to-beat blood pressure variability (BPV) is an indicator of cardiovascular autonomic modulation, however, the influence of recording duration on its assessment accuracy remains unclear. Therefore, we investigated whether BPV estimated from shortened acquisition windows remains comparable, equivalent, and reliable relative to an 8-min reference window. Continuous beat-to-beat blood pressure was recorded at rest via finger volume clamp technique in 26 adults (6 women). Beat-to-beat variability was estimated as standard deviation and average real variability for systolic blood pressure, cardiac output, and total peripheral resistance. Values obtained from an 8-min reference window were compared against progressively shorter windows (7- to 1-min). Analyses included linear mixed-effect models, two one-sided tests for equivalence, typical error (TE CV%), intraclass correlation coefficients (ICC), and Bland-Altman analyses. When analyzed by standard deviation, beat-to-beat variabilities across all variables were systematically underestimated with 1- and 2-min windows, losing statistical equivalence to the reference with windows shorter than 4 minutes. Conversely, average real variability showed less susceptibility to systematic error, maintaining equivalence at windows as short as 2 minutes. Nevertheless, for both standard deviation and average real variability, as the recording window shortened, absolute and relative reliabilities (TE CV% = 2.3 to 26% and 0.9 to 9.8%; ICC = 0.99 to 0.64 and 1.00 to 0.94, respectively) as well as measurement agreement progressively deteriorated. For short-term BPV assessment, average real variability is more resilient to window shortening than standard deviation, requiring at least 2 versus 4 min of continuous recording, respectively, to maintain statistical equivalence to an 8-min reference window.

Authors

Institutions

Publication Details

Journal
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Published
2026-11-26
DOI
https://doi.org/10.1152/ajpregu.90074.2026
Primary Topic
Heart Rate Variability and Autonomic Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Average real variability is more resilient than standard deviation to shortened recording windows in resting beat-to-beat hemodynamics

Lauro Casqueiro Vianna, Natan Daniel da Silva, Rafael Yokoyama Fecchio, Thais C. Marin et al.
American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Heart Rate Variability and Autonomic Control
article

Average real variability is more resilient than standard deviation to shortened recording windows in resting beat-to-beat hemodynamics

Lauro Casqueiro Vianna, Natan Daniel da Silva, Rafael Yokoyama Fecchio, Thais C. Marin, Lucas Ugliara, C. L. M. Forjaz
article en

Abstract

Beat-to-beat blood pressure variability (BPV) is an indicator of cardiovascular autonomic modulation, however, the influence of recording duration on its assessment accuracy remains unclear. Therefore, we investigated whether BPV estimated from shortened acquisition windows remains comparable, equivalent, and reliable relative to an 8-min reference window. Continuous beat-to-beat blood pressure was recorded at rest via finger volume clamp technique in 26 adults (6 women). Beat-to-beat variability was estimated as standard deviation and average real variability for systolic blood pressure, cardiac output, and total peripheral resistance. Values obtained from an 8-min reference window were compared against progressively shorter windows (7- to 1-min). Analyses included linear mixed-effect models, two one-sided tests for equivalence, typical error (TE CV%), intraclass correlation coefficients (ICC), and Bland-Altman analyses. When analyzed by standard deviation, beat-to-beat variabilities across all variables were systematically underestimated with 1- and 2-min windows, losing statistical equivalence to the reference with windows shorter than 4 minutes. Conversely, average real variability showed less susceptibility to systematic error, maintaining equivalence at windows as short as 2 minutes. Nevertheless, for both standard deviation and average real variability, as the recording window shortened, absolute and relative reliabilities (TE CV% = 2.3 to 26% and 0.9 to 9.8%; ICC = 0.99 to 0.64 and 1.00 to 0.94, respectively) as well as measurement agreement progressively deteriorated. For short-term BPV assessment, average real variability is more resilient to window shortening than standard deviation, requiring at least 2 versus 4 min of continuous recording, respectively, to maintain statistical equivalence to an 8-min reference window.

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Universidade de Brasília (BR), Universidade de São Paulo (BR)
Heart Rate Variability and Autonomic Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon