Development and Clinical Validation of a Multi-Antigen Immunochromatographic Assay for Brucellosis Detection

Brucellosis is a widespread zoonotic disease that poses a substantial threat to livestock production and public health. Although lipopolysaccharide-based serological assays are widely used for brucellosis detection, concerns regarding antigen preparation and cross-reactivity have encouraged the exploration of recombinant protein antigens. In this study, four recombinant Brucella proteins—OMP22, VirB12, BP26, and OMP10—were prepared and evaluated using indirect enzyme-linked immunosorbent assays (ELISAs). Colloidal gold immunochromatographic test (GICT) strips were then developed using each individual antigen or an equal-mass mixture of the four proteins. The antigen formulations were further evaluated using a fluorescent microsphere immunochromatographic assay (FMIA). In the ELISA evaluation, all four recombinant antigens remained reactive at a serum dilution of 1:3200 according to their antigen-specific OD450 cutoff values. No detectable cross-reactivity was observed with the non-target pathogen-positive sera tested. Using 50 bovine serum samples and the Rose Bengal plate test (RBPT) as the reference method, the four-antigen mixture achieved the highest observed overall percent agreement among the antigen formulations evaluated on both platforms, reaching 82.0% for GICT and 88.0% for FMIA. However, the difference in overall agreement between the two mixed-antigen assays was not statistically significant (two-sided exact McNemar test, p = 0.250). In the preliminary analytical evaluation using a single positive serum sample, the endpoint detection dilutions were 1:400 for GICT and 1:800 for FMIA. The FMIA results were interpreted after 7 min. These findings demonstrate the feasibility of combining recombinant Brucella antigens with fluorescent immunochromatography for rapid serological screening. Further validation using larger sample sets and independent biological replicates is required to establish the diagnostic performance and reproducibility of the assays.

Authors

Institutions

Publication Details

Journal
Animals
Published
2026-11-26
DOI
https://doi.org/10.3390/ani16233763
Primary Topic
Brucella: diagnosis, epidemiology, treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Development and Clinical Validation of a Multi-Antigen Immunochromatographic Assay for Brucellosis Detection

Jifu Ma, Qianqian Yuan, Peng Fan, Feifan Liu et al.
Animals
Brucella: diagnosis, epidemiology, treatment
article

Development and Clinical Validation of a Multi-Antigen Immunochromatographic Assay for Brucellosis Detection

Jifu Ma, Qianqian Yuan, Peng Fan, Feifan Liu, Hao Guo, Ying Ding, Hui Zhang, Zhen Wang
article en

Abstract

Brucellosis is a widespread zoonotic disease that poses a substantial threat to livestock production and public health. Although lipopolysaccharide-based serological assays are widely used for brucellosis detection, concerns regarding antigen preparation and cross-reactivity have encouraged the exploration of recombinant protein antigens. In this study, four recombinant Brucella proteins—OMP22, VirB12, BP26, and OMP10—were prepared and evaluated using indirect enzyme-linked immunosorbent assays (ELISAs). Colloidal gold immunochromatographic test (GICT) strips were then developed using each individual antigen or an equal-mass mixture of the four proteins. The antigen formulations were further evaluated using a fluorescent microsphere immunochromatographic assay (FMIA). In the ELISA evaluation, all four recombinant antigens remained reactive at a serum dilution of 1:3200 according to their antigen-specific OD450 cutoff values. No detectable cross-reactivity was observed with the non-target pathogen-positive sera tested. Using 50 bovine serum samples and the Rose Bengal plate test (RBPT) as the reference method, the four-antigen mixture achieved the highest observed overall percent agreement among the antigen formulations evaluated on both platforms, reaching 82.0% for GICT and 88.0% for FMIA. However, the difference in overall agreement between the two mixed-antigen assays was not statistically significant (two-sided exact McNemar test, p = 0.250). In the preliminary analytical evaluation using a single positive serum sample, the endpoint detection dilutions were 1:400 for GICT and 1:800 for FMIA. The FMIA results were interpreted after 7 min. These findings demonstrate the feasibility of combining recombinant Brucella antigens with fluorescent immunochromatography for rapid serological screening. Further validation using larger sample sets and independent biological replicates is required to establish the diagnostic performance and reproducibility of the assays.

AnimalsVol. 16(23)
Shihezi University (CN), Xinjiang Production and Construction Corps (CN)
Brucella: diagnosis, epidemiology, treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon