Tandem gait adds non-redundant value to wearable gait metrics in parkinsonian syndromes
Objective To compare the diagnostic contributions of wearable sensor-based gait paradigms for detecting parkinsonian and for differentiating early-stage Parkinson’s disease (ePD) from atypical parkinsonian disorders (APDs). Methods We enrolled 163 participants: 83 with ePD, 40 with APDs (13 with progressive supranuclear palsy and 27 with multiple system atrophy-parkinsonian type), and 40 healthy controls (HC). Participants completed seven gait assessments: the Timed Up and Go, cognitive dual task, narrow walkways, 360° turning, sway test, the Five Times Sit-to-Stand, and tandem gait. We defined three classification tasks: PD and APDs vs. HC, PD vs. HC, and PD vs. APDs. Five machine-learning classifiers (support vector machine, k -nearest neighbors, decision tree, random forest, and logistic regression) were evaluated using 814 sensor-based features. Performance was evaluated using nested stratified cross-validation. Individual paradigm classification, leave-one-paradigm analysis, and permutation importance were used to assess discriminative performance and contributions at the paradigm and feature levels. Results Nested classifier selection yielded full-gait AUROCs of 0.964 (sensitivity, 0.951; specificity, 0.850), 0.973 (sensitivity, 0.952; specificity, 0.850), and 0.810 (sensitivity, 0.600; specificity, 0.904) for the three tasks, respectively. In the single-paradigm analysis, tandem gait achieved the highest AUROC in Tasks 1 and 2 (0.949 and 0.947), whereas TUG achieved the highest AUROC in Task 3 (0.822). Leave-one-paradigm analysis showed that tandem gait was the only paradigm with a significant incremental contribution in Tasks 1 and 2. Removing tandem gait reduced AUROC by 0.067 (95% CI, 0.028–0.110) and 0.090 (95% CI, 0.033–0.164), respectively (Holm-adjusted p = 0.007 for both). No individual paradigm showed a significant incremental contribution in Task 3. Conclusion Wearable sensor-derived gait measures combined with machine learning reliably discriminated parkinsonism from healthy controls, whereas differentiation between PD and APDs remained more challenging. Tandem gait provided significant incremental discriminative value in the two tasks involving healthy controls. For PD versus APDs classification, the combination of TUG and tandem gait achieved a numerically comparable AUROC to the full gait battery, despite no individual paradigm showing a significant incremental contribution. These findings support task-specific and interpretable gait evaluation as an objective adjunct to clinical diagnosis.
Authors
- Junxiao Xie (ORCID: https://orcid.org/0000-0003-1556-1495)
- Huan Zhao (ORCID: https://orcid.org/0000-0001-6319-949X)
- Suhang Shang (ORCID: https://orcid.org/0000-0002-0896-204X)
- Meng Zhang (ORCID: https://orcid.org/0000-0002-1800-0928)
- Hongmei Cao
- Zhifen Guo
- Ning Zhang
- Jing Xu
- Xuerong Bai
- Xiaoyu Liu
Institutions
- Chinese University of Hong Kong (HK)
- First Affiliated Hospital of Xi'an Jiaotong University (CN)
- First Hospital of Xi'an (CN)
- Xi'an Jiaotong University (CN)
Publication Details
- Journal
- Frontiers in Aging Neuroscience
- Published
- 2026-11-26
- DOI
- https://doi.org/10.3389/fnagi.2026.2000704
- Primary Topic
- Balance, Gait, and Falls Prevention
- Type
- article
- Field-Weighted Citation Impact
- 0.00