AI-assisted head-and-neck CTA interpretation improves interns' accuracy and diagnostic confidence: a prospective, crossover educational study with blinded reference-standard readers

Background Head-and-neck CT angiography (CTA) is a complex, multi-territory modality that is difficult for trainees to master. Deep-learning (DL) tools can automatically reconstruct and flag vascular disease, but whether they improve trainee performance in this specific setting—and on which lesion types—remains unclear. Methods We conducted a prospective, within-subject crossover study with blinded reference-standard readers in which 30 first-year radiology interns read 160 head-and-neck CTA studies (100 abnormal, 60 normal) twice: once unassisted and once with a DL assistant (uAI Sphere, United Imaging Intelligence). Readings were separated by a washout of at least 6 weeks, and reading order was randomized. Two senior radiologists (associate-professor rank or above) served as the reference standard, reading independently and then reaching consensus, blinded to intern and AI outputs. Primary endpoint was lesion-level sensitivity; secondary endpoints included study-level specificity, accuracy, AUC, confidence, reading time, and automation-bias events. Questionnaire and focus-group data explored trust calibration. Results With AI assistance, lesion-level sensitivity rose from 73.4% to 87.1% (P < 0.001) and AUC from 0.81 to 0.90, while study-level specificity was unchanged (84.2% vs. 86.6%). Post-AI sensitivity was highest for intracranial aneurysms ≥3 mm (81.8% → 94.3%) and carotid stenosis ≥50% (71.7% → 89.1%), whereas the largest absolute gain was observed for dissection (55.6% → 74.1%), although its final sensitivity remained lower; the smallest gain was observed for rare/other disease (50.0% → 60.0%). Mean confidence rose from 2.85 to 3.78 and also rose on AI-wrong cases (2.31 → 3.55). Interns accepted 38% of AI false-positive marks and adopted AI under-calls in 32% of cases. Questionnaire and focus-group data showed anchoring on AI marks. Conclusion AI-assisted teaching of head-and-neck CTA should be stratified by lesion type and accompanied by explicit efforts to counter automation bias, rather than assumed to be uniformly helpful.

Authors

Institutions

Publication Details

Journal
Frontiers in Medicine
Published
2026-11-26
DOI
https://doi.org/10.3389/fmed.2026.2026360
Primary Topic
Artificial Intelligence in Healthcare and Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

AI-assisted head-and-neck CTA interpretation improves interns' accuracy and diagnostic confidence: a prospective, crossover educational study with blinded reference-standard readers

Aihong Cao, Lang Chen, Hongyan Li, Peng Du et al.
Frontiers in Medicine
Artificial Intelligence in Healthcare and Education
article

AI-assisted head-and-neck CTA interpretation improves interns' accuracy and diagnostic confidence: a prospective, crossover educational study with blinded reference-standard readers

Aihong Cao, Lang Chen, Hongyan Li, Peng Du, Yawen Zheng
article en

Abstract

Background Head-and-neck CT angiography (CTA) is a complex, multi-territory modality that is difficult for trainees to master. Deep-learning (DL) tools can automatically reconstruct and flag vascular disease, but whether they improve trainee performance in this specific setting—and on which lesion types—remains unclear. Methods We conducted a prospective, within-subject crossover study with blinded reference-standard readers in which 30 first-year radiology interns read 160 head-and-neck CTA studies (100 abnormal, 60 normal) twice: once unassisted and once with a DL assistant (uAI Sphere, United Imaging Intelligence). Readings were separated by a washout of at least 6 weeks, and reading order was randomized. Two senior radiologists (associate-professor rank or above) served as the reference standard, reading independently and then reaching consensus, blinded to intern and AI outputs. Primary endpoint was lesion-level sensitivity; secondary endpoints included study-level specificity, accuracy, AUC, confidence, reading time, and automation-bias events. Questionnaire and focus-group data explored trust calibration. Results With AI assistance, lesion-level sensitivity rose from 73.4% to 87.1% (P < 0.001) and AUC from 0.81 to 0.90, while study-level specificity was unchanged (84.2% vs. 86.6%). Post-AI sensitivity was highest for intracranial aneurysms ≥3 mm (81.8% → 94.3%) and carotid stenosis ≥50% (71.7% → 89.1%), whereas the largest absolute gain was observed for dissection (55.6% → 74.1%), although its final sensitivity remained lower; the smallest gain was observed for rare/other disease (50.0% → 60.0%). Mean confidence rose from 2.85 to 3.78 and also rose on AI-wrong cases (2.31 → 3.55). Interns accepted 38% of AI false-positive marks and adopted AI under-calls in 32% of cases. Questionnaire and focus-group data showed anchoring on AI marks. Conclusion AI-assisted teaching of head-and-neck CTA should be stratified by lesion type and accompanied by explicit efforts to counter automation bias, rather than assumed to be uniformly helpful.

Frontiers in MedicineVol. 13
Second Affiliated Hospital of Xuzhou Medical College (CN)
Artificial Intelligence in Healthcare and Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon