Immediate responses to stimulation of trigeminal-associated sites using conventional suction-type and wearable silicone SSP electrodes: An exploratory randomized three-arm study in healthy adults

Background Comparative evidence regarding the immediate subjective and physiological responses to conventional suction-type and wearable conductive silicone silver spike point (SSP) electrodes remains limited. Objective To compare responses to conventional SSP stimulation at V1-associated sites and wearable silicone SSP stimulation at V3-associated sites with a nonequivalent no-current control. Methods Fifty-four healthy young adults were randomized to control, conventional SSP, or silicone SSP groups (18 per group). Conventional electrodes were applied without current in the control group, whereas both active groups received 20 min of stimulation. The primary outcome was pre-to-post change in the Karolinska Sleepiness Scale (KSS). Exploratory secondary outcomes included electroencephalography (EEG), heart rate variability (HRV), and masseter electromyography (EMG). Analyses included mixed repeated-measures ANOVA and Welch ANOVA with Dunnett T3-adjusted comparisons. Results A significant time × group interaction was observed for KSS [F(2, 51) = 4.693, p = .013, partial η 2 = .155]. Mean ± SD changes were 0.53 ± 1.77, 1.14 ± 1.95, and 2.92 ± 3.28 points in the control, conventional SSP, and silicone SSP groups, respectively. Post hoc analysis showed a significant difference between the silicone SSP and control groups (mean difference, 2.389; 95% CI, 0.154–4.624; adjusted p = .034), but not between the two active stimulation groups (adjusted p = .162). No significant time × group interactions were observed for EEG, HRV, or EMG. Conclusion KSS changes differed between silicone SSP and no-current control, but superiority or equivalence relative to conventional SSP was not established. The simultaneous differences in stimulation site and electrode design prevent attribution of the observed findings to either factor independently.

Authors

Institutions

Publication Details

Journal
Technology and Health Care
Published
2026-11-26
DOI
https://doi.org/10.1177/09287329261511384
Primary Topic
Transcranial Magnetic Stimulation Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Immediate responses to stimulation of trigeminal-associated sites using conventional suction-type and wearable silicone SSP electrodes: An exploratory randomized three-arm study in healthy adults

Wonsik Bae, Hyunju Moon
Technology and Health Care
Transcranial Magnetic Stimulation Studies
article

Immediate responses to stimulation of trigeminal-associated sites using conventional suction-type and wearable silicone SSP electrodes: An exploratory randomized three-arm study in healthy adults

Wonsik Bae, Hyunju Moon
article en

Abstract

Background Comparative evidence regarding the immediate subjective and physiological responses to conventional suction-type and wearable conductive silicone silver spike point (SSP) electrodes remains limited. Objective To compare responses to conventional SSP stimulation at V1-associated sites and wearable silicone SSP stimulation at V3-associated sites with a nonequivalent no-current control. Methods Fifty-four healthy young adults were randomized to control, conventional SSP, or silicone SSP groups (18 per group). Conventional electrodes were applied without current in the control group, whereas both active groups received 20 min of stimulation. The primary outcome was pre-to-post change in the Karolinska Sleepiness Scale (KSS). Exploratory secondary outcomes included electroencephalography (EEG), heart rate variability (HRV), and masseter electromyography (EMG). Analyses included mixed repeated-measures ANOVA and Welch ANOVA with Dunnett T3-adjusted comparisons. Results A significant time × group interaction was observed for KSS [F(2, 51) = 4.693, p = .013, partial η 2 = .155]. Mean ± SD changes were 0.53 ± 1.77, 1.14 ± 1.95, and 2.92 ± 3.28 points in the control, conventional SSP, and silicone SSP groups, respectively. Post hoc analysis showed a significant difference between the silicone SSP and control groups (mean difference, 2.389; 95% CI, 0.154–4.624; adjusted p = .034), but not between the two active stimulation groups (adjusted p = .162). No significant time × group interactions were observed for EEG, HRV, or EMG. Conclusion KSS changes differed between silicone SSP and no-current control, but superiority or equivalence relative to conventional SSP was not established. The simultaneous differences in stimulation site and electrode design prevent attribution of the observed findings to either factor independently.

Technology and Health Care
Kaya University (KR), Kyungnam College of Information and Technology (KR)
Transcranial Magnetic Stimulation Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon
Immediate responses to stimulation of trigeminal-associated sites using conventional suction-type and wearable silicone SSP electrodes: An exploratory randomized three-arm study in healthy adults — Wonsik Bae, Hyunju Moon · Technology and Health Care (2026) | TGRS Research Map | TGRS