Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients

Rationale Whole-body tumor burden is an emerging biomarker for disease assessment and response monitoring in PET/CT, and automated approaches may enable standardized, observer-independent quantification. Automated and expert-defined tumor volumes differ in their delineation, and their agreement remains unclear. This method-comparison study evaluated the agreement between threshold-based AI volumetric PET metrics and expert-defined manual whole-body tumor volumes at baseline and during treatment. Methods In this retrospective single-center study, [¹⁸F]FDG-PET/CT examinations from 118 patients with histologically confirmed NSCLC were analyzed, comprising 118 baseline and 278 follow-up examinations (n = 396). Manual whole-body tumor segmentation was compared with automated metrics (TMTV41%, TMTVSUV4) from CE-marked software. Agreement was assessed using Lin’s concordance correlation coefficient (CCC), Bland–Altman analysis, coverage probability within predefined relative limits, agreement on the presence of measurable tumor burden, and agreement in the change from baseline. All follow-up examinations were included in a secondary analysis accounting for repeated examinations within patients. Results At baseline, CCC was 0.94 (95% CI 0.74–0.95) for TMTVSUV4 and 0.81 (0.35–0.86) for TMTV41%, with wide and asymmetric intervals. Concordance was lower at the first follow-up (0.74 and 0.40) and across all follow-up examinations (0.59 and 0.40). On the ratio scale, automated measurements deviated at the first follow-up, with geometric mean ratios of 1.46 (95% CI 1.19–1.79) for TMTV41% and 0.37 (0.29–0.48) for TMTVSUV4. Coverage probability within ± 20% of the manual reference was 26.3% for both metrics at baseline and 11.1% and 13.7% at the first follow-up. TMTVSUV4 returned a volume of zero in 28 of 278 follow-up examinations in which the expert reference remained positive. Agreement in the relative change from baseline was low (CCC 0.08 for TMTV41% and 0.44 for TMTVSUV4), and agreement in exploratory response categories defined by a ± 30% change in tumor volume was only fair (Cohen’s κ 0.32 and 0.35). Conclusion Automated threshold-based PET volumetry reflects overall tumor burden but is not interchangeable with anatomically guided expert delineation. Agreement is lower during treatment and is only fair when the change from baseline is classified into response categories, supporting the use of AI-based volumetry as a complementary tool rather than a replacement for expert assessment.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2026-11-26
DOI
https://doi.org/10.1186/s12880-026-03039-y
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients

Michael Ingrisch, Matthias Philipp Fabritius, Moritz Ludwig Schnitzer, Ricarda Ebner et al.
BMC Medical Imaging
Medical Imaging Techniques and Applications
article

Agreement between AI-based automated and expert-defined manual whole-body tumor volume assessment in [¹⁸F]FDG-PET/CT of NSCLC patients

Michael Ingrisch, Matthias Philipp Fabritius, Moritz Ludwig Schnitzer, Ricarda Ebner, Lalith Kumar Shiyam Sundar, Johannes Rübenthaler, Rudolf Alexander Werner, Amanda Tufman, Emma Zöller, Gabriel Tobias Sheikh, Jens Ricke, Bastian Oliver Sabel, Maurice M. Heimer, Felix L. Herr, Konrad Klimek, Clemens C. Cyran, Christian A. Dascalescu
article en

Abstract

Rationale Whole-body tumor burden is an emerging biomarker for disease assessment and response monitoring in PET/CT, and automated approaches may enable standardized, observer-independent quantification. Automated and expert-defined tumor volumes differ in their delineation, and their agreement remains unclear. This method-comparison study evaluated the agreement between threshold-based AI volumetric PET metrics and expert-defined manual whole-body tumor volumes at baseline and during treatment. Methods In this retrospective single-center study, [¹⁸F]FDG-PET/CT examinations from 118 patients with histologically confirmed NSCLC were analyzed, comprising 118 baseline and 278 follow-up examinations (n = 396). Manual whole-body tumor segmentation was compared with automated metrics (TMTV41%, TMTVSUV4) from CE-marked software. Agreement was assessed using Lin’s concordance correlation coefficient (CCC), Bland–Altman analysis, coverage probability within predefined relative limits, agreement on the presence of measurable tumor burden, and agreement in the change from baseline. All follow-up examinations were included in a secondary analysis accounting for repeated examinations within patients. Results At baseline, CCC was 0.94 (95% CI 0.74–0.95) for TMTVSUV4 and 0.81 (0.35–0.86) for TMTV41%, with wide and asymmetric intervals. Concordance was lower at the first follow-up (0.74 and 0.40) and across all follow-up examinations (0.59 and 0.40). On the ratio scale, automated measurements deviated at the first follow-up, with geometric mean ratios of 1.46 (95% CI 1.19–1.79) for TMTV41% and 0.37 (0.29–0.48) for TMTVSUV4. Coverage probability within ± 20% of the manual reference was 26.3% for both metrics at baseline and 11.1% and 13.7% at the first follow-up. TMTVSUV4 returned a volume of zero in 28 of 278 follow-up examinations in which the expert reference remained positive. Agreement in the relative change from baseline was low (CCC 0.08 for TMTV41% and 0.44 for TMTVSUV4), and agreement in exploratory response categories defined by a ± 30% change in tumor volume was only fair (Cohen’s κ 0.32 and 0.35). Conclusion Automated threshold-based PET volumetry reflects overall tumor burden but is not interchangeable with anatomically guided expert delineation. Agreement is lower during treatment and is only fair when the change from baseline is classified into response categories, supporting the use of AI-based volumetry as a complementary tool rather than a replacement for expert assessment.

BMC Medical Imaging
Johns Hopkins University (US), Johns Hopkins Medicine (US), LMU Klinikum (DE), Asklepios Fachkliniken München-Gauting (DE), German Center for Lung Research (DE), Munich Center for Machine Learning (DE), Comprehensive Pneumology Center München (DE), Ludwig-Maximilians-Universität München (DE)
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon