Diamond Quantum Sensors Detect Spin Fluctuations Associated with Stem Cell Differentiation

By repeatedly measuring the same nitrogen-vacancy (NV) quantum sensors embedded in substrate-fixed diamond nanopillars before and after cell removal, the researchers developed a paired-measurement approach that reduces the influence of differences between individual sensors. At all four sensing sites associated with differentiation-induced mouse embryonic stem cells, NV spin coherence times increased after cell removal. In contrast, undifferentiated control cells showed no consistent change. TEMPOL reference measurements and computational models yielded equivalent spin densities of 0.084–0.567 spins/nm3. These values describe model-dependent local magnetic responses, not directly measured absolute concentrations of particular intracellular radicals. [Quantum Biology Society] As stem cells differentiate, they undergo changes in gene expression, metabolism, and their cellular redox environment. Reactive oxygen species (ROS) and free radicals generated during these processes can participate in cellular signaling, but quantitatively monitoring such changes inside living cells remains challenging. Conventional fluorescent probes can be affected by how much dye enters a cell and how long it is exposed to light. Diamond quantum sensors, which detect microscopic magnetic fluctuations associated with electron spins, have therefore attracted attention as a possible alternative. However, quantum sensors can differ in their positions, orientations, and intrinsic spin properties. When measurements from different sensors or cells are compared directly, genuine biological changes may become difficult to distinguish from differences between the sensors themselves. A research team consisting of Abdul Nasir Kuzhiyan Thadathil and Yoko Shigeno of the Institute of Quantum Life Science (iQLS) at Japan's National Institutes for Quantum Science and Technology (QST), Hitoshi Niwa of Kumamoto University, and Hitoshi Ishiwata of QST and Chiba University proposed a strategy to address this problem by fixing quantum sensors within a diamond substrate. The researchers repeatedly measured the same nitrogen-vacancy (NV) centers with cells present and after the cells had been removed. They then examined how the differences in spin coherence were associated with induced embryonic stem-cell differentiation. Hitoshi Ishiwata served as the corresponding author. The study was posted to bioRxiv on November 17, 2026, as a preprint that has not yet undergone peer review. ■ Keeping the Sensors Fixed While Changing the Cellular Environment: Why Paired Measurements Matter The researchers fabricated diamond nanopillars approximately 300 nanometers (nm) in diameter and 3.2 micrometers (μm) in height, with a center-to-center spacing of 15 μm. Near the surface of each nanopillar were nitrogen-vacancy centers, atomic defects in the diamond lattice where a nitrogen atom replaces a carbon atom and an adjacent lattice site is vacant. The electron spin associated with an NV center can be manipulated using light and microwaves. Its quantum state is also sensitive to time-varying magnetic fields in the surrounding environment. The researchers used the fixed arrangement of nanopillars as a set of identifiable addresses, allowing individual NV sensors to be located and measured repeatedly. For their magnetic-noise calculations, they assumed an NV depth of approximately 10 nm beneath the diamond surface. However, this value was not obtained by directly measuring the depth of the nitrogen-14-implanted NV centers in the devices used in the study. Instead, the assumption was based on an earlier investigation of comparable 3 keV nitrogen-15 implantation conditions, which reported a mean NV depth of 10.5 ± 2.8 nm. This distinction is important because the distance between an NV center and nearby magnetic spins directly influences the strength of their interaction. Conventional approaches using freely dispersed nanodiamonds may require researchers to compare different particles inside and outside cells. Even when the same particle is examined, its position or orientation can change. Such differences complicate the interpretation of measured spin coherence times. The new platform addresses this limitation by keeping the NV sensor fixed. The researchers first measured a nanopillar associated with a living cell. They then removed the cell and measured exactly the same sensor again. The principle resembles weighing an object on the same scale before and after removing it. By keeping the measuring instrument unchanged, the contribution of the object can be distinguished more reliably from variations between instruments. Importantly, the NV defects were not freely moving particles circulating inside the cells. They remained embedded within diamond nanopillars fixed to the substrate, while the cells interacted with the nanopillar structures. The sensors therefore detected changes in the local magnetic environment associated with the cells. The paired-measurement strategy substantially reduced uncertainty arising from intrinsic differences in NV depth, orientation, and coherence characteristics. However, cell removal itself may also alter the local surface environment surrounding a nanopillar. Consequently, the difference measured before and after cell removal cannot automatically be attributed entirely to a specific free radical or other paramagnetic molecular species. The method provides a more controlled comparison of local magnetic environments, rather than direct chemical identification of the sources of those magnetic fluctuations. ■ NV Spin Control Remained Possible in Living Cells: Coherence Extended to 25.8 μs Before investigating stem-cell differentiation, the researchers evaluated whether the diamond nanopillar platform could operate in contact with living cells without producing obvious cellular damage. They used Hepa1-6 cells to examine several biological indicators, including metabolic activity, DNA synthesis, plasma membrane integrity, and apoptosis-related activity. The experiments employed complementary fluorescence-based assays. Metabolic activity was examined using alamarBlue, while apoptosis-related activity was evaluated through caspase-3/7 fluorescence measurements. DNA synthesis was assessed through EdU incorporation, and plasma membrane integrity was examined using fluorescent membrane and cell-viability stains. Under the investigated conditions, cells cultured on the diamond nanopillar arrays maintained detectable metabolic activity and DNA synthesis. The researchers also observed preserved plasma membrane integrity without detectable activation of the apoptosis-related markers examined. These findings supported the cellular compatibility of the nanopillar platform under the selected experimental conditions. However, the compatibility experiments used Hepa1-6 cells, which were different from the mouse embryonic stem cells subsequently used in the differentiation experiments. The findings therefore do not establish comprehensive biological safety for every cell type or exposure condition. Another important distinction concerns the use of fluorescent probes. Fluorescent reagents were used in the independent assays evaluating cellular compatibility. However, the central NV-based measurements of local magnetic fluctuations did not require introducing ROS-reactive fluorescent labeling agents. The researchers next characterized the quantum sensing performance of the nanopillars. They used optically detected magnetic resonance (ODMR), Rabi oscillations, and Hahn spin-echo measurements. ODMR detects changes in NV fluorescence associated with transitions between electron-spin states induced by microwave excitation. Rabi oscillations demonstrate that the spin state can be manipulated coherently by varying the duration of microwave pulses. Hahn spin-echo measurements provide information about how rapidly the electron-spin phase relationship decays in the surrounding magnetic environment. Across five nanopillars measured during the initial device characterization, the mean ODMR contrast was 14.9 ± 0.76%. The mean Rabi oscillation contrast was 27.1 ± 1.94%. The mean Hahn-echo spin coherence time, T2, was 2.94 ± 0.21 microseconds (μs). The researchers then examined NV sensors associated with living cells. The representative intracellular-environment measurements retained an ODMR contrast of approximately 10% and a Rabi contrast of approximately 20%. The Hahn-echo T2 remained approximately 3 μs. T2 describes the characteristic timescale over which a defined phase relationship in the NV electron-spin state is preserved. When the surrounding magnetic environment contains additional fluctuating spins, the NV center can lose coherence more rapidly. However, T2 in this experiment refers to the quantum coherence of the diamond sensor's electron spin. It does not represent the coherence lifetime of the stem cell itself. To extend the sensor's coherence time, the researchers applied Carr–Purcell–Meiboom–Gill (CPMG) dynamical decoupling. This technique uses repeated microwave refocusing pulses to suppress certain contributions to spin dephasing caused by fluctuations in the environment. As the number of refocusing pulses increased, the measured coherence time became longer. With five pulses, T2 reached 3.48 ± 0.68 μs. With 20 pulses, it increased to 7.04 ± 3.75 μs. With 60 pulses, it reached 25.8 ± 4.90 μs. The final value represented an approximately 8.6-fold extension relative to the intracellular Hahn-echo coherence time of approximately 3 μs. This demonstrated that the quantum state of an NV center could remain controllable for a comparatively extended period even when the nanopillar was associated with a living-cell environment. However, it does not establish that stem-cell differentiation itself depends on quantum coherence. The demonstrated quantum coherence belongs to the diamond sensor, which is

Authors

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2026-11-26
DOI
https://doi.org/10.5281/zenodo.24550988
Primary Topic
Diamond and Carbon-based Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

Diamond Quantum Sensors Detect Spin Fluctuations Associated with Stem Cell Differentiation

inquantio
Zenodo (CERN European Organization for Nuclear Research)
Diamond and Carbon-based Materials Research
article

Diamond Quantum Sensors Detect Spin Fluctuations Associated with Stem Cell Differentiation

inquantio
article en

Abstract

By repeatedly measuring the same nitrogen-vacancy (NV) quantum sensors embedded in substrate-fixed diamond nanopillars before and after cell removal, the researchers developed a paired-measurement approach that reduces the influence of differences between individual sensors. At all four sensing sites associated with differentiation-induced mouse embryonic stem cells, NV spin coherence times increased after cell removal. In contrast, undifferentiated control cells showed no consistent change. TEMPOL reference measurements and computational models yielded equivalent spin densities of 0.084–0.567 spins/nm3. These values describe model-dependent local magnetic responses, not directly measured absolute concentrations of particular intracellular radicals. [Quantum Biology Society] As stem cells differentiate, they undergo changes in gene expression, metabolism, and their cellular redox environment. Reactive oxygen species (ROS) and free radicals generated during these processes can participate in cellular signaling, but quantitatively monitoring such changes inside living cells remains challenging. Conventional fluorescent probes can be affected by how much dye enters a cell and how long it is exposed to light. Diamond quantum sensors, which detect microscopic magnetic fluctuations associated with electron spins, have therefore attracted attention as a possible alternative. However, quantum sensors can differ in their positions, orientations, and intrinsic spin properties. When measurements from different sensors or cells are compared directly, genuine biological changes may become difficult to distinguish from differences between the sensors themselves. A research team consisting of Abdul Nasir Kuzhiyan Thadathil and Yoko Shigeno of the Institute of Quantum Life Science (iQLS) at Japan's National Institutes for Quantum Science and Technology (QST), Hitoshi Niwa of Kumamoto University, and Hitoshi Ishiwata of QST and Chiba University proposed a strategy to address this problem by fixing quantum sensors within a diamond substrate. The researchers repeatedly measured the same nitrogen-vacancy (NV) centers with cells present and after the cells had been removed. They then examined how the differences in spin coherence were associated with induced embryonic stem-cell differentiation. Hitoshi Ishiwata served as the corresponding author. The study was posted to bioRxiv on November 17, 2026, as a preprint that has not yet undergone peer review. ■ Keeping the Sensors Fixed While Changing the Cellular Environment: Why Paired Measurements Matter The researchers fabricated diamond nanopillars approximately 300 nanometers (nm) in diameter and 3.2 micrometers (μm) in height, with a center-to-center spacing of 15 μm. Near the surface of each nanopillar were nitrogen-vacancy centers, atomic defects in the diamond lattice where a nitrogen atom replaces a carbon atom and an adjacent lattice site is vacant. The electron spin associated with an NV center can be manipulated using light and microwaves. Its quantum state is also sensitive to time-varying magnetic fields in the surrounding environment. The researchers used the fixed arrangement of nanopillars as a set of identifiable addresses, allowing individual NV sensors to be located and measured repeatedly. For their magnetic-noise calculations, they assumed an NV depth of approximately 10 nm beneath the diamond surface. However, this value was not obtained by directly measuring the depth of the nitrogen-14-implanted NV centers in the devices used in the study. Instead, the assumption was based on an earlier investigation of comparable 3 keV nitrogen-15 implantation conditions, which reported a mean NV depth of 10.5 ± 2.8 nm. This distinction is important because the distance between an NV center and nearby magnetic spins directly influences the strength of their interaction. Conventional approaches using freely dispersed nanodiamonds may require researchers to compare different particles inside and outside cells. Even when the same particle is examined, its position or orientation can change. Such differences complicate the interpretation of measured spin coherence times. The new platform addresses this limitation by keeping the NV sensor fixed. The researchers first measured a nanopillar associated with a living cell. They then removed the cell and measured exactly the same sensor again. The principle resembles weighing an object on the same scale before and after removing it. By keeping the measuring instrument unchanged, the contribution of the object can be distinguished more reliably from variations between instruments. Importantly, the NV defects were not freely moving particles circulating inside the cells. They remained embedded within diamond nanopillars fixed to the substrate, while the cells interacted with the nanopillar structures. The sensors therefore detected changes in the local magnetic environment associated with the cells. The paired-measurement strategy substantially reduced uncertainty arising from intrinsic differences in NV depth, orientation, and coherence characteristics. However, cell removal itself may also alter the local surface environment surrounding a nanopillar. Consequently, the difference measured before and after cell removal cannot automatically be attributed entirely to a specific free radical or other paramagnetic molecular species. The method provides a more controlled comparison of local magnetic environments, rather than direct chemical identification of the sources of those magnetic fluctuations. ■ NV Spin Control Remained Possible in Living Cells: Coherence Extended to 25.8 μs Before investigating stem-cell differentiation, the researchers evaluated whether the diamond nanopillar platform could operate in contact with living cells without producing obvious cellular damage. They used Hepa1-6 cells to examine several biological indicators, including metabolic activity, DNA synthesis, plasma membrane integrity, and apoptosis-related activity. The experiments employed complementary fluorescence-based assays. Metabolic activity was examined using alamarBlue, while apoptosis-related activity was evaluated through caspase-3/7 fluorescence measurements. DNA synthesis was assessed through EdU incorporation, and plasma membrane integrity was examined using fluorescent membrane and cell-viability stains. Under the investigated conditions, cells cultured on the diamond nanopillar arrays maintained detectable metabolic activity and DNA synthesis. The researchers also observed preserved plasma membrane integrity without detectable activation of the apoptosis-related markers examined. These findings supported the cellular compatibility of the nanopillar platform under the selected experimental conditions. However, the compatibility experiments used Hepa1-6 cells, which were different from the mouse embryonic stem cells subsequently used in the differentiation experiments. The findings therefore do not establish comprehensive biological safety for every cell type or exposure condition. Another important distinction concerns the use of fluorescent probes. Fluorescent reagents were used in the independent assays evaluating cellular compatibility. However, the central NV-based measurements of local magnetic fluctuations did not require introducing ROS-reactive fluorescent labeling agents. The researchers next characterized the quantum sensing performance of the nanopillars. They used optically detected magnetic resonance (ODMR), Rabi oscillations, and Hahn spin-echo measurements. ODMR detects changes in NV fluorescence associated with transitions between electron-spin states induced by microwave excitation. Rabi oscillations demonstrate that the spin state can be manipulated coherently by varying the duration of microwave pulses. Hahn spin-echo measurements provide information about how rapidly the electron-spin phase relationship decays in the surrounding magnetic environment. Across five nanopillars measured during the initial device characterization, the mean ODMR contrast was 14.9 ± 0.76%. The mean Rabi oscillation contrast was 27.1 ± 1.94%. The mean Hahn-echo spin coherence time, T2, was 2.94 ± 0.21 microseconds (μs). The researchers then examined NV sensors associated with living cells. The representative intracellular-environment measurements retained an ODMR contrast of approximately 10% and a Rabi contrast of approximately 20%. The Hahn-echo T2 remained approximately 3 μs. T2 describes the characteristic timescale over which a defined phase relationship in the NV electron-spin state is preserved. When the surrounding magnetic environment contains additional fluctuating spins, the NV center can lose coherence more rapidly. However, T2 in this experiment refers to the quantum coherence of the diamond sensor's electron spin. It does not represent the coherence lifetime of the stem cell itself. To extend the sensor's coherence time, the researchers applied Carr–Purcell–Meiboom–Gill (CPMG) dynamical decoupling. This technique uses repeated microwave refocusing pulses to suppress certain contributions to spin dephasing caused by fluctuations in the environment. As the number of refocusing pulses increased, the measured coherence time became longer. With five pulses, T2 reached 3.48 ± 0.68 μs. With 20 pulses, it increased to 7.04 ± 3.75 μs. With 60 pulses, it reached 25.8 ± 4.90 μs. The final value represented an approximately 8.6-fold extension relative to the intracellular Hahn-echo coherence time of approximately 3 μs. This demonstrated that the quantum state of an NV center could remain controllable for a comparatively extended period even when the nanopillar was associated with a living-cell environment. However, it does not establish that stem-cell differentiation itself depends on quantum coherence. The demonstrated quantum coherence belongs to the diamond sensor, which is

Zenodo (CERN European Organization for Nuclear Research)
Diamond and Carbon-based Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon