ІНЖЕНЕРНІ ТА ІНТЕР’ЄРНІ РІШЕННЯ У ПРОЄКТУВАННІ МІКРОКЛІМАТУ ГОТЕЛІВ І РЕСТОРАНІВ

The indoor environment of a hotel or restaurant cannot be reduced to the operation of ventilation and air-conditioning equipment alone. In this study, the microclimate is considered as the result of interaction among engineering systems, the building envelope, functional planning, and interior design. The aim was to relate these solutions to the functions of the principal groups of spaces. Building regulations, Ukrainian-language publications, and international studies were reviewed to identify the different microclimatic loads of guest rooms, entrance and lobby areas, restaurant, banquet and conference halls, open kitchens, hot-food preparation rooms, and humid spaces. The analysis shows that a single solution is unsuitable for all zones. Guest rooms require individual temperature control, low noise and draft risk, separate air extraction from bathrooms, and consideration of window orientation and shading. In public halls, ventilation output should follow actual occupancy, while diffusers, exhaust devices, and sensors must remain compatible with possible furniture arrangements and movable partitions. In restaurant production areas, local exhaust hoods need to operate together with organized make-up air and general ventilation, with airflow directed from guest areas toward the kitchen. Solar shading, vestibules, spatial separation, low-emission materials, and furniture placement can reduce or redistribute loads, but they do not replace engineering calculations. The study resulted in a coordination matrix linking functional zones with dominant loads, engineering measures, interior and planning solutions, and control parameters. The matrix is intended for use in new construction, reconstruction, and interior renovation, where it can help identify conflicts between technical and spatial decisions before the design is completed.

Authors

Institutions

Publication Details

Journal
Development Service Industry Management
Published
2026-11-26
DOI
https://doi.org/10.31891/dsim-2026-16(44)
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
NOV
article

ІНЖЕНЕРНІ ТА ІНТЕР’ЄРНІ РІШЕННЯ У ПРОЄКТУВАННІ МІКРОКЛІМАТУ ГОТЕЛІВ І РЕСТОРАНІВ

Vyacheslav Skrypnyk
Development Service Industry Management
Building Energy and Comfort Optimization
article

ІНЖЕНЕРНІ ТА ІНТЕР’ЄРНІ РІШЕННЯ У ПРОЄКТУВАННІ МІКРОКЛІМАТУ ГОТЕЛІВ І РЕСТОРАНІВ

Vyacheslav Skrypnyk
article en

Abstract

The indoor environment of a hotel or restaurant cannot be reduced to the operation of ventilation and air-conditioning equipment alone. In this study, the microclimate is considered as the result of interaction among engineering systems, the building envelope, functional planning, and interior design. The aim was to relate these solutions to the functions of the principal groups of spaces. Building regulations, Ukrainian-language publications, and international studies were reviewed to identify the different microclimatic loads of guest rooms, entrance and lobby areas, restaurant, banquet and conference halls, open kitchens, hot-food preparation rooms, and humid spaces. The analysis shows that a single solution is unsuitable for all zones. Guest rooms require individual temperature control, low noise and draft risk, separate air extraction from bathrooms, and consideration of window orientation and shading. In public halls, ventilation output should follow actual occupancy, while diffusers, exhaust devices, and sensors must remain compatible with possible furniture arrangements and movable partitions. In restaurant production areas, local exhaust hoods need to operate together with organized make-up air and general ventilation, with airflow directed from guest areas toward the kitchen. Solar shading, vestibules, spatial separation, low-emission materials, and furniture placement can reduce or redistribute loads, but they do not replace engineering calculations. The study resulted in a coordination matrix linking functional zones with dominant loads, engineering measures, interior and planning solutions, and control parameters. The matrix is intended for use in new construction, reconstruction, and interior renovation, where it can help identify conflicts between technical and spatial decisions before the design is completed.

Development Service Industry Management(4)
Poltava State Agrarian University (UA)
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Laika access coming soon